Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Dumafix Glue
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Seam sealant
Uses advised against
No information available at present.
Manufacturers & Suppliers
Dumaplast nv
manufacturer
Vliegplein 41, B-9990 Maldegem, Belgium
http://www.dumaplast.be
Emergency Contacts
Dumaplast nv
+32 50 72 901 11
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Titanium dioxide (in powder form containing 1 % or more of particles with aerodynamic diameter <= 10 μm) EC: 236-675-5 | 13463-67-7 | 2% | Yes |
| N-(3-(trimethoxysilyl)propyl)ethylenediamine EC: 217-164-6 | 1760-24-3 | 0.1 - 1% | Yes |
| Trimethoxyvinylsilane EC: 220-449-8 | 2768-02-7 | 0.1 - 1% | Yes |
Impurities, test data and additional information may have been taken into account in classifying and labelling the product. For the text of the H-phrases and classification codes (GHS/CLP), see Section 16. The substances named in this section are given with their actual, appropriate classification! For substances that are listed in appendix VI, table 3.1 of the regulation (EC) no. 1272/2008 (CLP regulation) this means that all notes that may be given here for the named classification have been taken into account.
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply person with fresh air and consult doctor according to symptoms.
Wipe off residual product carefully with a soft, dry cloth. Remove polluted, soaked clothing immediately, wash thoroughly with plenty of water and soap.
Symptoms: irritation of the skin (flare)
Remove contact lenses. Wash thoroughly for several minutes using copious water. Seek medical help if necessary.
Rinse the mouth thoroughly with water. Do not induce vomiting - give copious water to drink. Consult doctor immediately.
Immediate Medical Attention
Consult doctor immediately (ingestion), seek medical help if necessary (eyes), consult doctor according to symptoms (inhalation).
Medical Treatment
Symptomatic treatment.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water jet spray / alcohol resistant foam / CO2 / dry extinguisher. Adapt to the nature and extent of fire.
None known
In case of fire the following can develop: Oxides of carbon, Oxides of nitrogen, Methanol, Formaldehyde, Toxic gases
In case of fire and/or explosion do not breathe fumes.
Firefighter Protection
Protective respirator with independent air supply. According to size of fire Full protection, if necessary.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Leave the danger zone if possible, use existing emergency plans if necessary.
Dam up. Resolve leaks if this possible without risk. Prevent from entering drainage system. Prevent surface and ground-water infiltration, as well as ground penetration.
Soak up with absorbent material, Pick up mechanically, Flush residue using copious water.
Materials: universal binding agent, sand, diatomaceous earth, sawdust
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with eyes or skin. Avoid long lasting or intensive contact with skin. Observe directions on label and instructions for use.
Not to be stored in gangways or stair wells. Store product closed and only in original packing. Store in a well ventilated place. Store in a dry place.
Eating, drinking, smoking, as well as food-storage, is prohibited in work-room. General hygiene measures for the handling of chemicals are applicable. Wash hands before breaks and at end of work. Keep away from food, drink and animal feedingstuffs. Remove contaminated clothing and protective equipment before entering areas in which food is consumed.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure good ventilation. This can be achieved by local suction or general air extraction. If this is insufficient to maintain the concentration under the WEL or AGW values, suitable breathing protection should be worn. Applies only if maximum permissible exposure values are listed here. Suitable assessment methods for reviewing the effectiveness of protection measures adopted include metrological and non-metrological investigative techniques. These are specified by e.g. EN 14042. EN 14042 "Workplace atmospheres. Guide for the application and use of procedures for the assessment of exposure to chemical and biological agents".
Chemical resistant protective gloves (EN ISO 374). If applicable Protective gloves made of butyl (EN ISO 374). Protective nitrile gloves (EN ISO 374). Protective hand cream recommended. Permeation time (penetration time) in minutes: 30. The breakthrough times determined in accordance with EN 16523-1 were not obtained under practical conditions. The recommended maximum wearing time is 50% of breakthrough time. Additional information on hand protection - No tests have been performed. In the case of mixtures, the selection has been made according to the knowledge available and the information about the contents. Selection of materials derived from glove manufacturer's indications. Final selection of glove material must be made taking the breakthrough times, permeation rates and degradation into account. Selection of a suitable glove depends not only on the material but also on other quality characteristics and varies from manufacturer to manufacturer. In the case of mixtures, the resistance of glove materials cannot be predicted and must therefore be tested before use. The exact breakthrough time of the glove material can be requested from the protective glove manufacturer and must be observed.
With danger of contact with eyes. Tight fitting protective goggles with side protection (EN 166).
Normally not necessary.
Protective working garments (e.g. safety shoes EN ISO 20345, long-sleeved protective working garments).
No information available at present.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable with proper storage and handling.
Product may hydrolyse.
None known
Strong heat, Protect from humidity., Product may hydrolyse.
Avoid contact with strong alkalis., Avoid contact with strong acids.
On contact with moist air: Methanol
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
E.g. suitable incineration plant.
Hardened product: E.g. dispose at suitable refuse site.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- Not applicable
- Shipping Name
- Not applicable
- Transport Class
- Not applicable
- Packing Group
- Not applicable
Regulatory Information
Chemical regulations, safety assessments, and compliance status
General hygiene measures for the handling of chemicals are applicable. National requirements/regulations on safety and health protection must be applied when using work equipment.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Dumafix Glue?
The signal word is no signal word.
What is the physical form of Dumafix Glue?
Dumafix Glue is a paste, solid. with according to specification color. It has characteristic odor.
What is the solubility of Dumafix Glue?
Insoluble
What is Dumafix Glue used for?
Seam sealant
What is the melting point of Dumafix Glue?
The melting point is There is no information available on this parameter. and the boiling point is There is no information available on this parameter..