Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Uses Information
Overview
Dumafix glue commonly used seam sealant.
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
Hazard Classifications
GHS Hazard Pictograms & Safety Symbols
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
Precautionary Statements
Manufacturers & Suppliers
Authorized suppliers, manufacturers, and distribution network information
24/7 Emergency Response
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
ISA
+49 (0) 700 / 24 112 112 (ISA)
DE
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
mixtureChemical Components & Hazardous Substances
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Trimethoxyvinylsilane EC: 220-449-8 | 2768-02-7 | 1-5% | Hazardous |
Composition Notes
Impurities, test data and additional information may have been taken into account in classifying and labelling the product. For the text of the H-phrases and classification codes (GHS/CLP), see Section 16. The substances named in this section are given with their actual, appropriate classification! For substances that are listed in appendix VI, table 3.1 of the regulation (EC) no. 1272/2008 (CLP regulation) this means that all notes that may be given here for the named classification have been taken into account.
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
Inhalation Exposure
Supply person with fresh air and consult doctor according to symptoms.
Skin Contact
Wipe off residual product carefully with a soft, dry cloth. Remove polluted, soaked clothing immediately, wash thoroughly with plenty of water and soap, in case of irritation of the skin (flare), consult a doctor.
Symptoms:
in case of irritation of the skin (flare)
Eye Contact
Remove contact lenses. Wash thoroughly for several minutes using copious water. Seek medical help if necessary.
Ingestion/Swallowing
Rinse the mouth thoroughly with water. Do not induce vomiting - give copious water to drink. Consult doctor immediately.
Symptoms:
Upon contact with stomach acid development of: Methanol
Immediate Medical Attention Required
n.c.
Medical Treatment
n.c.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Exposure Controls & Personal Protective Equipment
Occupational exposure limits, engineering controls, and required safety equipment
Engineering Controls
Ensure good ventilation. This can be achieved by local suction or general air extraction. If this is insufficient to maintain the concentration under the WEL or AGW values, suitable breathing protection should be worn. Applies only if maximum permissible exposure values are listed here. Suitable assessment methods for reviewing the effectiveness of protection measures adopted include metrological and non-metrological investigative techniques. These are specified by e.g. BS EN 14042. BS EN 14042 "Workplace atmospheres. Guide for the application and use of procedures for the assessment of exposure to chemical and biological agents".
Hand Protection
Chemical resistant protective gloves (EN 374). If applicable Protective gloves made of butyl (EN 374). Protective nitrile gloves (EN 374). Protective hand cream recommended. Permeation time (penetration time) in minutes: 30. The breakthrough times determined in accordance with EN 16523-1 were not obtained under practical conditions. The recommended maximum wearing time is 50% of breakthrough time. Additional information on hand protection - No tests have been performed. In the case of mixtures, the selection has been made according to the knowledge available and the information about the contents. Selection of materials derived from glove manufacturer's indications. Final selection of glove material must be made taking the breakthrough times, permeation rates and degradation into account. Selection of a suitable glove depends not only on the material but also on other quality characteristics and varies from manufacturer to manufacturer. In the case of mixtures, the resistance of glove materials cannot be predicted and must therefore be tested before use. The exact breakthrough time of the glove material can be requested from the protective glove manufacturer and must be observed.
Eye Protection
With danger of contact with eyes. Tight fitting protective goggles with side protection (EN 166).
Respiratory Protection
Normally not necessary.
Skin/Body Protection
Protective working garments (e.g. safety shoes EN ISO 20345, long-sleeved protective working garments).
Environmental Exposure Controls
No information available at present.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
UN Number
n.a.
Packing Group
n.a.
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for Dumafix glue?
The signal word for this substance is "no signal word".
What is the physical form of Dumafix glue?
Dumafix glue is a paste, solid with according to specification color. It has aromatic odor.
What is the solubility of Dumafix glue?
Not determined
What is Dumafix glue used for?
Seam sealant
What is the melting point of Dumafix glue?
The melting point is <-40 °C and the boiling point is Not determined.