Chemical Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Uses Information
Overview
3M Attest Biological Indicators for Steam 1261, 1261P, 1262, 1262P & 1262R is a glass ampule with test strip and media, enclosed in a covered plastic vial. substance commonly used sterilization process indicator, to indicate attainment of conditions for sterilization..
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
GHS Hazard Pictograms & Safety Symbols
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
Precautionary Statements
Chemical Manufacturers & Supply Chain
Authorized suppliers, manufacturers, and distribution network information
3M Australia
manufacturer
24/7 Emergency Response & Poison Control
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
Emergency Contact
1800 097 146
AU
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
mixtureChemical Components & Hazardous Substances
Chemical Name | CAS Number | Concentration | Hazardous |
---|---|---|---|
Water | 7732-18-5 | 99.79452% | โ Non-hazardous |
Dextrose | 50-99-7 | 0.18445% | โ Non-hazardous |
Inosine | 58-63-9 | 0.0099603% | โ Non-hazardous |
L-Tyrosine | 60-18-4 | 0.0066402% | โ Non-hazardous |
L-Alanine | 56-41-7 | 0.0033201% | โ Non-hazardous |
Bromocresol Purple, Monosodium salt | 62625-30-3 | 0.001007097% | โ Non-hazardous |
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
๐ฝ๏ธ Ingestion/Swallowing
Rinse mouth. If you feel unwell, get medical attention.
Fire Fighting Measures & Emergency Response
Fire suppression methods, extinguishing media, and firefighting safety procedures
โ Suitable Extinguishing Media
Use a fire fighting agent suitable for ordinary combustible material such as water or foam to extinguish.
โ ๏ธ Specific Fire Hazards
None inherent in this product.
๐ก๏ธ Firefighter Protection Equipment
Wear full protective clothing, including helmet, self-contained, positive pressure or pressure demand breathing apparatus, bunker coat and pants, bands around arms, waist and legs, face mask, and protective covering for exposed areas of the head.
Accidental Release Measures & Spill Response
Emergency spill cleanup procedures, containment methods, and environmental protection
๐จ Emergency Procedures
Ventilate the area with fresh air. Observe precautions from other sections.
๐ Environmental Precautions
Avoid release to the environment.
๐งน Cleanup Methods
Collect as much of the spilled material as possible. Clean up residue with an appropriate solvent.
Cleanup Materials:
bentonite, vermiculite, or commercially available inorganic absorbent material.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Safe Handling & Storage Procedures
Industrial handling precautions, storage conditions, and workplace safety requirements
โ ๏ธ Handling Precautions
โข Avoid skin contact with hot material.
๐ช Storage Conditions
โข No special storage requirements.
Exposure Controls & Personal Protective Equipment (PPE)
Occupational exposure limits, engineering controls, and required safety equipment
๐ญ Engineering Controls
No engineering controls required.
๐งค Hand Protection
No chemical protective gloves are required.
๐๏ธ Eye Protection
None required.
๐ท Respiratory Protection
None required.
Chemical Stability & Reactivity Data
Chemical stability, hazardous reactions, and incompatible materials information
โ Chemical Stability
Stable.
โ๏ธ Reactivity
This material is considered to be non reactive under normal use conditions
โ ๏ธ Hazardous Reactions
Hazardous polymerisation will not occur.
๐ซ Conditions to Avoid
None known.
๐งช Incompatible Materials
None known.
๐จ Hazardous Decomposition Products
Not applicable. Not specified.
Ecological Information & Environmental Impact
Environmental toxicity, biodegradation, bioaccumulation, and ecological effects data
๐ฑ Toxicity
๐ฑ Persistence and degradability
๐ฑ Bioaccumulative potential
๐ฑ Mobility in soil
๐ฑ Other adverse effects
Waste Disposal & Treatment Methods
Waste disposal procedures, treatment methods, and regulatory compliance requirements
โป๏ธ Waste Treatment Methods
Dispose of waste product in a permitted industrial waste facility. As a disposal alternative, incinerate in a permitted waste incineration facility. Proper destruction may require the use of additional fuel during incineration processes.
๐๏ธ Product Disposal Recommendations
Dispose of contents/ container in accordance with the local/regional/national/international regulations.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
Regulatory Information & Compliance
Chemical regulations, safety assessments, and regulatory compliance status
๐ Regulatory Summary
This product is regulated by the Therapeutics Goods Administration and is exempt from compliance with the Industrial Chemicals (Notification and Assessment) Act 1989 as amended.
โ Chemical Safety Assessment
No chemical safety assessment has been performed for this substance.
โน๏ธ Additional Regulatory Information
This product is an article therefore the Standard for the Uniform Scheduling of Medicines and Poisons Schedule is not applicable.
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the physical form of 3M Attest Biological Indicators for Steam 1261, 1261P, 1262, 1262P & 1262R?
3M Attest Biological Indicators for Steam 1261, 1261P, 1262, 1262P & 1262R is a liquid. appearing as glass ampule with test strip and media, enclosed in a covered plastic vial. with multicolour color. It has nearly odourless odor.
What is the solubility of 3M Attest Biological Indicators for Steam 1261, 1261P, 1262, 1262P & 1262R?
Negligible
What is 3M Attest Biological Indicators for Steam 1261, 1261P, 1262, 1262P & 1262R used for?
Sterilization process indicator, To indicate attainment of conditions for sterilization.
What is the melting point of 3M Attest Biological Indicators for Steam 1261, 1261P, 1262, 1262P & 1262R?
The melting point is No data available. and the boiling point is Approximately 100 โ [Details:(applies to media)].