Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- TRANS CLEAR
Regulatory Identifiers
- CAS Number
- N/A
- REACH No.
- Not applicable (mixture)
Identified Uses
Adhesive Sealing compound
Uses advised against
No uses advised against known
Manufacturers & Suppliers
TEC7
distributor
Industrielaan 5B, B-2250 Olen
+32 14 85 97 37
Novatech International N.V.
manufacturer
Industrielaan 5B, B-2250 Olen
+32 14 85 97 37
Emergency Contacts
BIG
+32 14 58 45 45
24h/24h
EN, FR, DE, NL
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| trimethoxyvinylsilane EC: 220-449-8 | 2768-02-7 | 0.1 - 1% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove victim into fresh air. In case of respiratory problems, consult a doctor/medical service.
Symptoms: No effects known.
If possible, wipe up/dry remove chemical. Then rinse/shower immediately with (lukewarm) water. If irritation persists, consult a doctor/medical service.
Symptoms: No effects known.
Rinse immediately with (lukewarm) water. Remove contact lenses, if present and easy to do. Continue rinsing. If irritation persists, consult a doctor/medical service.
Symptoms: No effects known.
Rinse mouth with water. If you feel unwell, consult a doctor/medical service. Do not wait for symptoms to occur to consult Poison Center.
Symptoms: No effects known.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Small fire: Quick-acting ABC powder extinguisher, Quick-acting BC powder extinguisher, Quick-acting class B foam extinguisher, Quick-acting CO2 extinguisher. Major fire: Class B foam (not alcohol-resistant).
Small fire: Water (quick-acting extinguisher, reel); risk of puddle expansion. Major fire: Water; risk of puddle expansion.
Upon combustion: CO and CO2 are formed.
No specific fire-fighting instructions required.
Firefighter Protection
Gloves (EN 374). Protective clothing (EN 14605 or EN 13034). Heat/fire exposure: self-contained breathing apparatus (EN 136 + EN 137).
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
No naked flames. Exposure to fire/heat: keep upwind. Exposure to fire/heat: have neighbourhood close doors and windows.
Contain released product.
Solid spill: cover with absorbent material. Scoop solid spill into closing containers. Clean contaminated surfaces with an excess of water.
Materials: absorbent material
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Keep away from naked flames/heat. Observe strict hygiene. Keep container tightly closed.
Store in a cool area. Store in a dry area. Keep container in a well-ventilated place. Keep only in the original container. Keep container tightly closed.
Observe strict hygiene.
Keep away from naked flames/heat.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Keep away from naked flames/heat. Carry operations in the open/under local exhaust/ventilation or with respiratory protection.
Protective gloves against chemicals (EN 374). Materials: nitrile rubber (> 120 minutes, 0.4 mm, Class 4), natural rubber (> 120 minutes, 0.4 mm, Class 4), PVA (> 120 minutes, 0.4 mm, Class 4)
Safety glasses (EN 166).
Respiratory protection not required in normal conditions.
Protective clothing (EN 14605 or EN 13034).
See sections 6.2, 6.3 and 13
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
Heating increases the fire hazard.
No data available.
Keep away from naked flames/heat.
No data available.
Upon combustion: CO and CO2 are formed.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Remove waste in accordance with local and/or national regulations. Do not discharge into drains or the environment. Dispose of at authorized waste collection point.
Dispose of at authorized waste collection point.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
No chemical safety assessment is required for a mixture.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for TRANS CLEAR?
The signal word is no signal word.
What is the physical form of TRANS CLEAR?
TRANS CLEAR is a paste with variable in colour, depending on the composition color. It has characteristic odour odor.
What is TRANS CLEAR used for?
Adhesive Sealing compound
What is the melting point of TRANS CLEAR?
The melting point is No data available in the literature and the boiling point is No data available in the literature.