Product Name
Strontium ICP standard traceable to SRM from NIST Sr(NO) in HNO 2-3% 1000 mg/l Sr CertiPUR
Product Code
170354

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Reagent for analysis

Overview

Strontium ICP standard traceable to SRM from NIST Sr(NO) in HNO 2-3% 1000 mg/l Sr CertiPUR commonly used reagent for analysis.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Warning)

Hazard Classifications

Met. Corr. Category 1 H290
Skin Irr. Category 2 H315
Eye Irrit. Category 2 H319

GHS Hazard Pictograms & Safety Symbols

GHS05 GHS Hazard Pictogram: Corrosive hazard - Materials that can cause severe skin burns and eye damage

GHS05

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H290: May be corrosive to metals.
  • H315: Causes skin irritation.
  • H319: Causes serious eye irritation.

Precautionary Statements

  • IF ON SKIN: Wash with plenty of soap and water.
  • IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Merck KGaA company logo - Safety Data Sheet supplier organization

Merck KGaA

undefined

๐Ÿ“

64271 Darmstadt, Germany

๐ŸŒ

DE

๐Ÿ“ž

+49 6151 72-0

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Aqueous solution

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
nitric acid 7697-37-2 1-5% โš ๏ธ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

fresh air.

๐Ÿ–๏ธ Skin Contact

wash off with plenty of water. Remove contaminated clothing.

๐Ÿ‘๏ธ Eye Contact

rinse out with plenty of water. Call in ophthalmologist.

๐Ÿฝ๏ธ Ingestion/Swallowing

immediately make victim drink water (two glasses at most). Consult a physician.

Symptoms:

methaemoglobinaemia after the uptake of large quantities.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
colourless
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
liquid
๐Ÿ‘ƒ Odor
odourless
๐Ÿ“Š Odor Threshold
No information available.
๐Ÿงช Ph
ca. 0,5 at 20 C
๐ŸงŠ Melting Point
No information available.
Critical Property
๐Ÿ’จ Boiling Point
No information available.
Critical Property
๐Ÿ”ฅ Flash Point
No information available.
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
No information available.
๐Ÿ’จ Vapor Pressure
No information available.
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
ca.1,013 g/cm at 20 C
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not available
๐Ÿ”ฅ Flammability
No information available.
๐Ÿ“Š Upper Explosive Limit
No information available.
๐Ÿ“Š Lower Explosive Limit
No information available.
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
No information available.
๐Ÿ“Š Decomposition Temperature
No information available.
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
No information available.
๐Ÿ“Š Solubility In Water
No information available.
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
May be corrosive to metals.
๐Ÿ“Š Dynamic Viscosity
No information available.
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Technical measures and appropriate working operations should be given priority over the use of personal protective equipment.

๐Ÿงค Hand Protection

full contact: Glove material: Nitrile rubber Glove thickness: 0,11 mm Break through time: - 480 min splash contact: Glove material: Nitrile rubber Glove thickness: 0,11 mm Break through time: - 480 min The protective gloves to be used must comply with the specifications of EC Directive 89/686/EEC and the related standard EN374, for example KCL 741 Dermatril L (full contact), KCL 741 Dermatril L (splash contact). The breakthrough times stated above were determined by KCL in laboratory tests acc. to EN374 with samples of the recommended glove types. This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).

๐Ÿ‘๏ธ Eye Protection

Safety glasses

๐Ÿ˜ท Respiratory Protection

required when vapours/aerosols are generated. Recommended Filter type: filter E-(P2) The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

๐Ÿฆบ Skin/Body Protection

protective clothing

๐ŸŒ Environmental Exposure Controls

Do not let product enter drains.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

UN 3264

๐Ÿ“ฆ Proper Shipping Name

CORROSIVE LIQUID, ACIDIC, INORGANIC, N.O.S. (CONT. NITRIC ACID SOLUTION)

โš ๏ธ Transport Hazard Class

8

๐Ÿ“‹ Packing Group

III

๐Ÿš› ADR Transport Precautions

yes

๐Ÿšข IMDG Maritime Transport Precautions

yes

โœˆ๏ธ IATA Air Transport Precautions

no

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Strontium ICP standard traceable to SRM from NIST Sr(NO) in HNO 2-3% 1000 mg/l Sr CertiPUR?

The signal word for this substance is "warning".

What is the physical form of Strontium ICP standard traceable to SRM from NIST Sr(NO) in HNO 2-3% 1000 mg/l Sr CertiPUR?

Strontium ICP standard traceable to SRM from NIST Sr(NO) in HNO 2-3% 1000 mg/l Sr CertiPUR is a liquid with colourless color. It has odourless odor.

What is Strontium ICP standard traceable to SRM from NIST Sr(NO) in HNO 2-3% 1000 mg/l Sr CertiPUR used for?

Reagent for analysis

What are the hazard statements for Strontium ICP standard traceable to SRM from NIST Sr(NO) in HNO 2-3% 1000 mg/l Sr CertiPUR?

This substance has 3 hazard statements: H290: May be corrosive to metals. H315: Causes skin irritation. H319: Causes serious eye irritation.

What is the melting point of Strontium ICP standard traceable to SRM from NIST Sr(NO) in HNO 2-3% 1000 mg/l Sr CertiPUR?

The melting point is No information available. and the boiling point is No information available..