Product Information

Product Name
Sulfur ICP standard traceable to SRM from NIST H₂SO₄ in H₂O 10000 mg/l S CertiPUR®
Product Code
170385

Regulatory Identifiers

CAS Number
N/A
REACH No.
see section 3

Identified Uses

Reagent for analysis

Manufacturers & Suppliers

M

Merck KGaA

manufacturer

64271 Darmstadt, Germany

+49 6151 72-0

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Met. Corr. Cat. 1 H290

GHS Pictograms

GHS05 - Corrosive

GHS05

Hazard Statements

H290 May be corrosive to metals.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
sulphuric acid 7664-93-9 1 - 5% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

fresh air.

Skin contact

wash off with plenty of water. Remove contaminated clothing.

Eye contact

rinse out with plenty of water with the eyelid held wide open. Call in ophthalmologist if necessary.

Ingestion

make victim drink water (two glasses at most). Consult doctor if feeling unwell.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Unsuitable media

For this substance/mixture no limitations of extinguishing agents are given.

Specific hazards

Not combustible. Ambient fire may liberate hazardous vapours.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Do not breathe vapours, aerosols. Evacuate the danger area, observe emergency procedures, consult an expert.

Environmental

Do not let product enter drains.

Cleanup methods

Take up with liquid-absorbent and neutralising material (e.g. Chemizorb® H⁺, Merck Art. No. 101595). Clean up affected area.

Materials: liquid-absorbent and neutralising material (e.g. Chemizorb® H⁺, Merck Art. No. 101595)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Observe label precautions.

Storage

Tightly closed. Store at +15°C to +25°C.

Hygiene

Change contaminated clothing. Preventive skin protection recommended. Wash hands after working with substance.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Technical measures and appropriate working operations should be given priority over the use of personal protective equipment. See section 7.1.

Hands

full contact: Glove material: Nitrile rubber, Glove thickness: 0,11 mm, Break through time: > 480 min. splash contact: Glove material: Nitrile rubber, Glove thickness: 0,11 mm, Break through time: > 480 min. The protective gloves to be used must comply with the specifications of EC Directive 89/686/EEC and the related standard EN374, for example KCL 741 Dermatril® L (full contact), KCL 741 Dermatril® L (splash contact). The breakthrough times stated above were determined by KCL in laboratory tests acc. to EN374 with samples of the recommended glove types. This recommendation applies only to the product stated in the safety data sheet <(>, <)> supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).

Eyes

Safety glasses

Respiratory

required when vapours/aerosols are generated. Recommended Filter type: Filter P 2 (acc. to DIN 3181) for solid and liquid particles of harmful substances. The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

Skin/Body

protective clothing

Environmental

Do not let product enter drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Evaporation Rate
---
Explosive Limits
---
Colour
colourless
Physical State Data
liquid
Relative Density
ca.1,018 g/cm³ at 20 °C
Dynamic Viscosity
---
Density
---
Odor Threshold
not applicable
Softening Point
---
Relative Evaporation Rate
---
Molecular Weight
---
Melting Point
---
Cloud Point
---
Freezing Point
---
Solubility In Fat
---
Form
liquid
Physical State
liquid
Decomposition Temperature
---
Lower Explosive Limit
---
Bulk Density
---
Vapor Pressure
---
Properties Status
---
Vapor Density
---
Metal Corrosion
May be corrosive to metals.
Odor
odourless
State Under Standard Conditions
---
Appearance
---
Colour Intensity
---
Boiling Point
---
Flammability
---
Auto Ignition Temperature
---
Crystallisation Point
---
Upper Explosive Limit
---
Partition Coefficient
---
Solubility In Water
soluble
Voc Content
---
Ph
< 1 at 20 °C
Flash Point
---
Solubility
---
Solidification Point
---
Kinematic Viscosity
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable under standard ambient conditions (room temperature).

Reactivity

has a corrosive effect

Hazardous reactions

Violent reactions possible with: The generally known reaction partners of water.

Avoid

no information available

Incompatible

animal/vegetable tissues, Metals. Gives off hydrogen by reaction with metals.

Decomposition

no information available

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
3264
Shipping Name
CORROSIVE LIQUID, ACIDIC, INORGANIC, N.O.S. (CONT. SULPHURIC ACID)
Transport Class
8
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Sulfur ICP standard traceable to SRM from NIST H₂SO₄ in H₂O 10000 mg/l S CertiPUR®?

The signal word is warning.

What is the physical form of Sulfur ICP standard traceable to SRM from NIST H₂SO₄ in H₂O 10000 mg/l S CertiPUR®?

Sulfur ICP standard traceable to SRM from NIST H₂SO₄ in H₂O 10000 mg/l S CertiPUR® is a liquid with colourless color. It has odourless odor.

What is Sulfur ICP standard traceable to SRM from NIST H₂SO₄ in H₂O 10000 mg/l S CertiPUR® used for?

Reagent for analysis

What are the hazard statements for Sulfur ICP standard traceable to SRM from NIST H₂SO₄ in H₂O 10000 mg/l S CertiPUR®?

This substance has 1 hazard statement:

  • H290: May be corrosive to metals.