NextSDS Logo
Me

Meguin Hydraulikoel HLP 15

DANGER Liquid SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Meguin Hydraulikoel HLP 15

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Hydraulic oil
Uses Advised Against
No information available at present.

Overview

Meguin Hydraulikoel HLP 15 commonly used hydraulic oil.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Asp. Tox. Category 1 H304

GHS Hazard Pictograms & Safety Symbols

GHS08 GHS Hazard Pictogram: Serious health hazard - Carcinogenic, mutagenic, or toxic to organs

GHS08

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H304: May be fatal if swallowed and enters airways.

Precautionary Statements

  • P101: If medical advice is needed, have product container or label at hand.
  • P102: Keep out of reach of children.
  • P301+P310: IF SWALLOWED: Immediately call a POISON CENTER / doctor.
  • P331: Do NOT induce vomiting.
  • P405: Store locked up.
  • P501: Dispose of contents / container to an approved waste disposal facility.
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Meguin GmbH & Co. KG Mineraloelwerke

manufacturer

Rodener Strasse 25 66740 Saarlouis

DE

06831/89 09-0

06831/89 09-62

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

LMR

+49 (0) 700 / 24 112 112 (LMR)

DE

LMR

+1 872 5888271 (LMR)

US

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Destillaten (aardolie), met oplosmiddel van was ontdane lichte paraffinische
EC: 265-159-2
64742-56-9 75-100% Hazardous
Basisolie - niet gespecifieerd
EC: 265-158-7
64742-55-8 75-100% Hazardous
2,6-Di-tert-butylphenol
EC: 204-884-0
128-39-2 0.1-0.25% Hazardous

Composition Notes

Impurities, test data and additional information may have been taken into account in classifying and labelling the product. For the text of the H-phrases and classification codes (GHS/CLP), see Section 16. The substances named in this section are given with their actual, appropriate classification! For substances that are listed in appendix VI, table 3.1 of the regulation (EC) no. 1272/2008 (CLP regulation) this means that all notes that may be given here for the named classification have been taken into account. The addition of the highest concentrations listed here can result in a classification. Only when this classification is listed in Section 2 does it apply. In all other cases the total concentration is below the classification.

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Remove person from danger area. Supply person with fresh air and consult doctor according to symptoms.

Symptoms:

Irritation of the respiratory tract (on vapour formation)

Skin Contact

Remove polluted, soaked clothing immediately, wash thoroughly with plenty of water and soap, in case of irritation of the skin (flare), consult a doctor.

Symptoms:

Drying of the skin (with long-term contact), Dermatitis (skin inflammation)

Eye Contact

Remove contact lenses. Wash thoroughly for several minutes using copious water. Seek medical help if necessary.

Symptoms:

Irritation of the eyes

Ingestion/Swallowing

Rinse the mouth thoroughly with water. Do not induce vomiting - give copious water to drink. Consult doctor immediately. In case of vomiting, keep head low so that the stomach content does not reach the lungs.

Symptoms:

Nausea, Gastrointestinal disturbances, Vomiting, Danger of aspiration, Oedema of the lungs

Immediate Medical Attention Required

Consult doctor immediately (for ingestion). Seek medical help if necessary (for eye contact). Consult doctor according to symptoms (for inhalation). Symptomatic treatment.

Medical Treatment

Symptomatic treatment.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Partition Coefficient
Does not apply to mixtures.
Explosive Limits
Not available
Evaporation Rate
Not available
Odor Threshold
Not available
State Under Standard Conditions
Not available
Solubility In Water
Not available
Colour
Yellow
Physical State Data
liquid
Flammability
Combustible.
Metal Corrosion
Not available
Freezing Point
There is no information available on this parameter.
Properties Status
Not available
Vapor Density
Not available
Lower Explosive Limit
There is no information available on this parameter.
Softening Point
Not available
Solubility In Fat
Not available
Crystallisation Point
Not available
Solidification Point
Not available
Voc Content
Not available
Molecular Weight
Not available
Relative Density
0,85 g/ml (20C)
Dynamic Viscosity
Not available
Odor
Characteristic
Form
Not available
Density
0,85 g/ml (20C)
Critical Property
Flash Point
205 C
Critical Property
Appearance
Not available
Relative Evaporation Rate
Not available
Cloud Point
Not available
Solubility
Insoluble
Bulk Density
Not available
Boiling Point
There is no information available on this parameter.
Critical Property
Colour Intensity
Not available
Melting Point
There is no information available on this parameter.
Critical Property
Auto Ignition Temperature
There is no information available on this parameter.
Decomposition Temperature
There is no information available on this parameter.
Kinematic Viscosity
15,7 mm2/s (40C) 3,6 mm2/s (100C)
Physical State
Liquid
Critical Property
Upper Explosive Limit
There is no information available on this parameter.
Ph
Mixture is non-soluble (in water).
Vapor Pressure
There is no information available on this parameter.
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Ensure good ventilation. This can be achieved by local suction or general air extraction. If this is insufficient to maintain the concentration under the WEL or AGW values, suitable breathing protection should be worn. Applies only if maximum permissible exposure values are listed here. Suitable assessment methods for reviewing the effectiveness of protection measures adopted include metrological and non-metrological investigative techniques. These are specified by e.g. EN 14042. EN 14042 "Workplace atmospheres. Guide for the application and use of procedures for the assessment of exposure to chemical and biological agents".

Hand Protection

Chemical resistant protective gloves (EN ISO 374). If applicable Protective Neoprene / polychloroprene gloves (EN ISO 374). Protective nitrile gloves (EN ISO 374). Minimum layer thickness in mm: 0,17 Permeation time (penetration time) in minutes: >= 60 The breakthrough times determined in accordance with EN 16523-1 were not obtained under practical conditions. The recommended maximum wearing time is 50% of breakthrough time. Protective PVC gloves (EN ISO 374). Protective hand cream recommended. Additional information on hand protection - No tests have been performed. In the case of mixtures, the selection has been made according to the knowledge available and the information about the contents. Selection of materials derived from glove manufacturer's indications. Final selection of glove material must be made taking the breakthrough times, permeation rates and degradation into account. Selection of a suitable glove depends not only on the material but also on other quality characteristics and varies from manufacturer to manufacturer. In the case of mixtures, the resistance of glove materials cannot be predicted and must therefore be tested before use. The exact breakthrough time of the glove material can be requested from the protective glove manufacturer and must be observed.

Eye Protection

Tight fitting protective goggles (EN 166) with side protection, with danger of splashes.

Respiratory Protection

Normally not necessary. With oil mist formation: Filter A2 P2 (EN 14387), code colour brown, white Observe wearing time limitations for respiratory protection equipment.

Skin/Body Protection

Protective working garments (e.g. safety shoes EN ISO 20345, long-sleeved protective working garments).

Environmental Exposure Controls

No information available at present.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Meguin Hydraulikoel HLP 15?

The signal word for this substance is "danger".

What is the physical form of Meguin Hydraulikoel HLP 15?

Meguin Hydraulikoel HLP 15 is a liquid with yellow color. It has characteristic odor.

What is the solubility of Meguin Hydraulikoel HLP 15?

Insoluble

What is Meguin Hydraulikoel HLP 15 used for?

Hydraulic oil

What are the hazard statements for Meguin Hydraulikoel HLP 15?

This substance has 1 hazard statements: H304: May be fatal if swallowed and enters airways.

What is the melting point of Meguin Hydraulikoel HLP 15?

The melting point is There is no information available on this parameter. and the boiling point is There is no information available on this parameter..