01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
EvoFluid HLP 32
Product Code
A100286

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Industrial use

Manufacturers & Suppliers

oelheld GmbH logo

oelheld GmbH

manufacturer

Ulmer Str. 133-139, 70188 Stuttgart, GERMANY

+49-(0)711-16863-0

http://www.oelheld.de

Emergency Contacts

Dr. Schnödt

+49 71 11 68 63-997

out of office hours

DE, EN

Mr Philipp Storr

+49 71 11 68 63-992

out of office hours

DE, EN

Mr Martin Storr

+49 71 11 68 63-993

out of office hours

DE, EN

Mr Speth

+49 71 11 68 63-994

out of office hours

DE, EN

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mixture of solventrefined mineral oil and additives.

Note L is valid for this product or one or many of its ingredients. Note L: The classification as a carcinogen need not apply if it can be shown that the substance contains less than 3 % DMSO extract as measured by IP 346 'Determination of polycyclic aromatics in unused lubricating base oils and asphaltene free petroleum fractions - Dimethyl sulphoxide extraction refractive index method', Institute of Petroleum, London. This note applies only to certain complex oil-derived substances in Annex VI. For the wording of the listed risk phrases refer to section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of complaints.

Skin contact

Wash with water and soap and rinse thoroughly.

Symptoms: Generally the product does not irritate the skin.

Eye contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

Ingestion

Do not induce vomiting

Immediate Medical Attention

call for medical help immediately

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, powder or water spray. Fight larger fire with alcohol resistant foam.

Unsuitable media

Water with full jet

Specific hazards

Under certain fire conditions, traces of other toxic gases cannot be excluded, e.g.: Carbon monoxide (CO)

Instructions

Do not inhale explosion gases or combustion gases.

Firefighter Protection

Wear self-contained respiratory protective device.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Keep contaminated washing water and dispose of appropriately.

Cleanup methods

Absorb with liquid-binding material

Materials: sand, diatomite, acid binders, universal binders, sawdust

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Open and handle receptacle with care.

Storage

Store in cool, dry conditions in well sealed receptacles. Protect from heat, direct sunlight and UV-rays.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Protective gloves or protective skin cream. Material of gloves: Nitrile rubber, NBR. Penetration time of glove material: At a glove thickness of about 0,4 mm the value of the permeation breakthrough in accordance with EN 374 is for chemically similar products according to the manufacturer: >480 min. (Degradation EN 374 rating class 6). These statements are based on laboratory test methods which could not simulate working conditions exactly. The responsibility rests with the end user for choosing the right gloves for his application.

Eyes

Goggles recommended during refilling

Respiratory

Not necessary if room is well-ventilated.

Skin/Body

Protective work clothing

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Fluid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Fluid
Colour
Yellow
Colour Intensity
---
Form
---
Odor
Characteristic
Odor Threshold
Not determined.
Ph
Not applicable.
Melting Point
Undetermined.
Boiling Point
>250°C
Flash Point
>190°C
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not applicable.
Vapor Pressure
Not determined.
Vapor Density
Not determined.
Relative Density
---
Bulk Density
---
Density
0.87 g/cm³
Flammability
Product is not explosive. However formation of explosive air/vapour mixtures above the flash point or in case of strong misting is possible.
Upper Explosive Limit
Not determined.
Lower Explosive Limit
Not determined.
Explosive Limits
---
Auto Ignition Temperature
Not determined.
Decomposition Temperature
Not determined.
Solubility
---
Partition Coefficient
Not determined.
Solubility In Water
Not miscible or difficult to mix.
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
32 mm²/s
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Reactivity

No further relevant information available.

Hazardous reactions

No dangerous reactions known.

Incompatible

Strong oxidizing agents

Decomposition

No decomposition if used according to specifications. No dangerous decomposition products known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for EvoFluid HLP 32?

The signal word is no signal word.

What is the physical form of EvoFluid HLP 32?

EvoFluid HLP 32 is a fluid appearing as fluid with yellow color. It has characteristic odor.

What is EvoFluid HLP 32 used for?

Industrial use

What is the melting point of EvoFluid HLP 32?

The melting point is Undetermined. and the boiling point is >250°C.