Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- EvoFluid HLP 32
- Product Code
- A100286
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Industrial use
Manufacturers & Suppliers
oelheld GmbH
manufacturer
Ulmer Str. 133-139, 70188 Stuttgart, GERMANY
+49-(0)711-16863-0
http://www.oelheld.de
Emergency Contacts
Dr. Schnödt
+49 71 11 68 63-997
out of office hours
DE, EN
Mr Philipp Storr
+49 71 11 68 63-992
out of office hours
DE, EN
Mr Martin Storr
+49 71 11 68 63-993
out of office hours
DE, EN
Mr Speth
+49 71 11 68 63-994
out of office hours
DE, EN
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Mixture of solventrefined mineral oil and additives.
Note L is valid for this product or one or many of its ingredients. Note L: The classification as a carcinogen need not apply if it can be shown that the substance contains less than 3 % DMSO extract as measured by IP 346 'Determination of polycyclic aromatics in unused lubricating base oils and asphaltene free petroleum fractions - Dimethyl sulphoxide extraction refractive index method', Institute of Petroleum, London. This note applies only to certain complex oil-derived substances in Annex VI. For the wording of the listed risk phrases refer to section 16.
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air; consult doctor in case of complaints.
Wash with water and soap and rinse thoroughly.
Symptoms: Generally the product does not irritate the skin.
Rinse opened eye for several minutes under running water. Then consult a doctor.
Do not induce vomiting
Immediate Medical Attention
call for medical help immediately
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, powder or water spray. Fight larger fire with alcohol resistant foam.
Water with full jet
Under certain fire conditions, traces of other toxic gases cannot be excluded, e.g.: Carbon monoxide (CO)
Do not inhale explosion gases or combustion gases.
Firefighter Protection
Wear self-contained respiratory protective device.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Keep contaminated washing water and dispose of appropriately.
Absorb with liquid-binding material
Materials: sand, diatomite, acid binders, universal binders, sawdust
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Open and handle receptacle with care.
Store in cool, dry conditions in well sealed receptacles. Protect from heat, direct sunlight and UV-rays.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Protective gloves or protective skin cream. Material of gloves: Nitrile rubber, NBR. Penetration time of glove material: At a glove thickness of about 0,4 mm the value of the permeation breakthrough in accordance with EN 374 is for chemically similar products according to the manufacturer: >480 min. (Degradation EN 374 rating class 6). These statements are based on laboratory test methods which could not simulate working conditions exactly. The responsibility rests with the end user for choosing the right gloves for his application.
Goggles recommended during refilling
Not necessary if room is well-ventilated.
Protective work clothing
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No further relevant information available.
No dangerous reactions known.
Strong oxidizing agents
No decomposition if used according to specifications. No dangerous decomposition products known.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for EvoFluid HLP 32?
The signal word is no signal word.
What is the physical form of EvoFluid HLP 32?
EvoFluid HLP 32 is a fluid appearing as fluid with yellow color. It has characteristic odor.
What is EvoFluid HLP 32 used for?
Industrial use
What is the melting point of EvoFluid HLP 32?
The melting point is Undetermined. and the boiling point is >250°C.