NextSDS Logo
Safety Data Sheet EN

RENOFORM ALUROL

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
RENOFORM ALUROL

Regulatory Identifiers

CAS Number
N/A

Manufacturers & Suppliers

F

FUCHS EUROPE SCHMIERSTOFFE GMBH

manufacturer

Friesenheimer Str. 15 D-68169 Mannheim

++49 (0)621/3701-0

Emergency Contacts

Emergency Contact

++49 (0)621/3701-333

Switch Board

++49 (0)621/3701-0

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified na: r-phrases

Hazard Classifications

Aquatic Acute

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mixture of synthetic base oils with additives.

Chemical Name CAS Number Concentration Hazardous
Höhere Fettalkohole --- 50 - 99% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of symptoms. (eventually by inhaling the overheated product)

Eye contact

Rinse opened eye for several minutes under running water.

Ingestion

In case of persistent symptoms consult doctor.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, extinguishing powder or water jet. Fight larger fires with water jet or alcohol-resistant foam. Use fire fighting measures that suit the environment.

Unsuitable media

Water with a full water jet.

Firefighter Protection

In case of fire fighting: wear self containing breathing apparatus

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Particular danger of slipping on leaked/ spilled product.

Environmental

Do not allow to enter drainage system, surface or ground water. Prevent from spreading (e.g. by binding or oil barriers). Do not allow to enter the ground/ soil.

Cleanup methods

Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust). Dispose of the material collected according to regulations.

Materials: sand, diatomite, acid binders, universal binders, sawdust

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Prevent formation of aerosols.

Storage

No special requirements.

Fire prevention

Do not heat up to temperatures close to the flash point.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No further data; see item 7.

Hands

Protective gloves and protective skin cream.

Eyes

Safety glasses recommended during refilling.

Respiratory

Not required.

Skin/Body

Protective work clothing.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Fluid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Yellow
Colour Intensity
---
Form
Fluid
Odor
Characteristic
Odor Threshold
---
Ph
---
Melting Point
Not determined
Boiling Point
not applicable or not determined
Flash Point
130°C
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
---
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
0.85 g/cm³
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
Product is not selfigniting.
Decomposition Temperature
Not determined
Solubility
Not miscible or difficult to mix
Partition Coefficient
---
Solubility In Water
Not miscible or difficult to mix
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
8 mm²/s
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Hazardous reactions

No dangerous reactions known

Avoid

No decomposition if used according to specifications.

Decomposition

No dangerous decomposition products known

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Smaller quantities have to be disposed in line with local legislation. When storing used mineral oil products, ensure that the categories for waste oil and mixing instructions are observed. Delivery of waste oil only to officially authorized collectors.

Waste Codes

12 01 10 synthetic machining oils EWC
15 01 99 EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
3082
Shipping Name
ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID, N.O.S.
Transport Class
9
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Designation according to EU guidelines: The product has been classified and labelled in accordance with EC Directives until 2001/59/EC (28. ATP). Code letter and hazard designation of product: N Dangerous for the environment. Risk phrases: 50 Very toxic to aquatic organisms. Safety phrases: 61 Avoid release to the environment. Refer to special instructions/Safety data sheets.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for RENOFORM ALUROL?

The signal word is na: r-phrases.

What is the physical form of RENOFORM ALUROL?

RENOFORM ALUROL is a fluid with yellow color. It has characteristic odor.

What is the solubility of RENOFORM ALUROL?

Not miscible or difficult to mix

What is the melting point of RENOFORM ALUROL?

The melting point is Not determined and the boiling point is not applicable or not determined.