NextSDS Logo
Safety Data Sheet EN

STANTEX G 7607

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
STANTEX G 7607

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Fiber auxiliary, Raw material for industry

Manufacturers & Suppliers

P

Pulcra Chemicals, S.L.

national supplier

Polgono Industrial San Vicente, s/n 08755 Castellbisbal Spain

Emergency Contacts

Pulcra Chemicals, S.L.

+ 34 93 8177100

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Acute Tox. Cat. 4 H332
Eye Dam. Cat. 1 H318
Aquatic Chronic Cat. 2 H411

GHS Pictograms

GHS05 - Corrosive

GHS05

GHS07 - Health hazard

GHS07

GHS09 - Environmental hazard

GHS09

Hazard Statements

H318 Causes serious eye damage.
H332 Harmful if inhaled.
H411 Toxic to aquatic life with long lasting effects.

Precautionary Statements

P261 Avoid breathing mist or vapours.
P273 Avoid release to the environment.
P280 Wear eye protection/ face protection.
P391 Collect spillage.
IF INHALED: Remove person to fresh air and keep comfortable for breathing. Call a POISON CENTER/ doctor if you feel unwell.
IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER/ doctor.

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type Mixture

Mixture Fatty amine, ethoxylated additives

Chemical Name CAS Number Concentration Hazardous
Alcohols, C12-15, ethoxylated 68131-39-5 30 - 50% Yes
Talgalkylamin ethoxylat EC: 500-153-8 61791-26-2 1 - 20% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. If breathing is difficult, remove victim to fresh air and keep at rest in a position comfortable for breathing. Call a physician immediately. Contact a poison control center.

Skin contact

Wash with plenty of soap and water. Cover wound with sterile dressing. Take off contaminated clothing and shoes immediately. Call a physician immediately.

Symptoms: Skin irritation

Eye contact

If easy to do, remove contact lens, if worn. Rinse immediately with plenty of water, also under the eyelids. Get medical attention immediately.

Symptoms: burning or stinging of the eye

Ingestion

Rinse mouth. Do NOT induce vomiting. Immediately call a POISON CENTER/ doctor. If a person vomits when lying on his back, place him in the recovery position. Get medical attention immediately.

Immediate Medical Attention

Call a physician immediately (for inhalation and skin contact). Get medical attention immediately (for eye contact and ingestion). If you feel unwell, seek medical advice (show the label where possible). Show this safety data sheet to the doctor in attendance. Treat symptomatically. Basic medical care.

Medical Treatment

Treat symptomatically. Basic medical care.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Handle only in a place equipped with local exhaust (or other appropriate exhaust).

Hands

Material : Protective gloves complying with EN 374. Remarks : Gloves must be inspected prior to use. Wash hands before breaks and at the end of workday. Gloves should be discarded and replaced if there is any indication of degradation or chemical breakthrough. The suitability for a specific workplace should be discussed with the producers of the protective gloves. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time.

Eyes

Tightly fitting safety goggles Wear a faceshield or other full face protection if there is a potential for direct contact to the face with dusts, mists, or aerosols. Equipment should conform to EN 166

Respiratory

In case of inadequate ventilation wear respiratory protection. In case of mist, spray or aerosol exposure wear suitable personal respiratory protection and protective suit. Suitable respiratory equipment: Respirator with combination filter for vapour/particulate (EN 141) See information supplied by the manufacturer. Filter type : Combined particulates, inorganic and acidic gas/vapour, ammonia/amines and organic vapour type (ABEK-P)

Skin/Body

Choose body protection according to the amount and concentration of the dangerous substance at the work place. Additional body garments should be used based upon the task being performed (e.g., sleevelets, apron, gauntlets, disposable suits) to avoid exposed skin surfaces.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Kinematic Viscosity
No data available
Voc Content
---
Dynamic Viscosity
No data available
Relative Evaporation Rate
---
Properties Status
---
Lower Explosive Limit
No data available
Odor Threshold
No data available
Solubility In Water
(20 C) dispersible
Form
---
Bulk Density
---
Explosive Limits
---
Colour Intensity
---
Vapor Pressure
No data available
Flash Point
149 C
Molecular Weight
---
Density
0,947 g/cm3
Relative Density
No data available
Metal Corrosion
---
Crystallisation Point
---
Boiling Point
No data available
Auto Ignition Temperature
No data available
Odor
hydrocarbon-like
State Under Standard Conditions
---
Cloud Point
---
Appearance
---
Evaporation Rate
No data available
Freezing Point
No data available
Vapor Density
---
Physical State
liquid
Decomposition Temperature
No data available
Upper Explosive Limit
No data available
Ph
7,5 (20 C)
Solubility In Fat
---
Melting Point
No data available
Physical State Data
liquid
Colour
yellow
Flammability
---
Solubility
---
Softening Point
---
Solidification Point
---
Partition Coefficient
No data available
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN 3082
Shipping Name
ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID, N.O.S.
Transport Class
9
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for STANTEX G 7607?

The signal word is danger.

What is the physical form of STANTEX G 7607?

STANTEX G 7607 is a liquid with yellow color. It has hydrocarbon-like odor.

What is STANTEX G 7607 used for?

Fiber auxiliary, Raw material for industry

What are the hazard statements for STANTEX G 7607?

This substance has 3 hazard statements:

  • H318: Causes serious eye damage.
  • H332: Harmful if inhaled.
  • H411: Toxic to aquatic life with long lasting effects.

What is the melting point of STANTEX G 7607?

The melting point is No data available and the boiling point is No data available.

Compliance Scanner

Scan your compliance