NextSDS Logo
Po

Potassium standard solution 1000 g/ml (Plasma HIQU)

WARNING Liquid SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Potassium standard solution 1000 g/ml (Plasma HIQU)
Product Code
CL01.1101

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Reagent for analysis

Overview

Potassium standard solution 1000 g/ml (Plasma HIQU) is a liquid, colourless substance commonly used reagent for analysis.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Warning :)

Hazard Classifications

Skin Irrit. Category 2 H315

GHS Hazard Pictograms & Safety Symbols

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H315: Causes skin irritation.

Precautionary Statements

  • P280: Wear protective gloves, protective clothing, eye protection, face protection.
  • P305 + P351 + P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

CHEM-LAB NV

manufacturer

Industriezone De Arend 2 B-8210 ZEDELGEM - BELGIUM

BE

+32 50 78 26 54

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

CHEM-LAB NV

00 (32) 50.28.83.20

BE

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Hazardous Ingredients:

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Nitric acid 67 - 69% (Pico-Pure)
EC: 231-714-2
7697-37-2 2-5% Hazardous
Potassium nitrate a.r.
EC: 231-818-8
7757-79-1 0.1-1% Hazardous
Water (Ultra Pure)
EC: 231-791-2
7732-18-5 90% Non-hazardous
First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Fresh air.

Skin Contact

Wash off with plenty of water. Remove contaminated clothing.

Eye Contact

Rinse out with plenty of water for at least 10 minutes with the eyelid held wide open. lmmediately call an ophtalmologist.

Ingestion/Swallowing

Never give anything by mouth to an unconscious person. Immediately make victim drink water (two glasses at most). Call in physician.

Immediate Medical Attention Required

No data available

Medical Treatment

No data available

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Boiling Point
101C
Critical Property
Solidification Point
Not available
Kinematic Viscosity
Not available
Freezing Point
Not available
Explosive Limits
Not available
Vapor Density
Not available
Lower Explosive Limit
Not available
Form
Liquid
Appearance
Liquid, Colourless
Flammability
Not available
Upper Explosive Limit
Not available
Colour
Colourless
Density
1,02 g/ml
Critical Property
Solubility
Not available
Relative Density
Not available
Ph
pH < 1
Partition Coefficient
Not available
Odor
Odourless
Decomposition Temperature
Not available
Auto Ignition Temperature
Not available
Odor Threshold
Not available
Solubility In Water
soluble
Physical State Data
liquid
Voc Content
Not available
Relative Evaporation Rate
Not available
Metal Corrosion
Not available
Molecular Weight
Not available
Physical State
Liquid
Critical Property
Evaporation Rate
Not available
Solubility In Fat
Not available
Crystallisation Point
Not available
Cloud Point
Not available
Properties Status
Not available
Dynamic Viscosity
Not available
Colour Intensity
Not available
Vapor Pressure
Not available
Softening Point
Not available
Flash Point
Not available
Bulk Density
Not available
State Under Standard Conditions
Not available
Melting Point
-3C
Critical Property
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Protective clothing should be selected specificlly for the working place, depending on concentration and quantity of the hazardous substances handled. The resistance of the protective clothing to chemicals should be ascertained with the respective supplier. See section 7.1

Hand Protection

Required.

Eye Protection

Required.

Respiratory Protection

Required when vapours/aerosols are generated. The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

Skin/Body Protection

Required.

Environmental Exposure Controls

Do not allow to enter sewerage system.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

UN 3264

Proper Shipping Name

Corrosive liquid, acidic, inorganic, n.o.s. (Nitric acid solution)

Transport Hazard Class

8

Packing Group

III

ADR Transport Precautions

no

IMDG Maritime Transport Precautions

no

IATA Air Transport Precautions

no

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Potassium standard solution 1000 g/ml (Plasma HIQU)?

The signal word for this substance is "warning".

What is the physical form of Potassium standard solution 1000 g/ml (Plasma HIQU)?

Potassium standard solution 1000 g/ml (Plasma HIQU) is a liquid appearing as liquid, colourless with colourless color. It has odourless odor.

What is Potassium standard solution 1000 g/ml (Plasma HIQU) used for?

Reagent for analysis

What are the hazard statements for Potassium standard solution 1000 g/ml (Plasma HIQU)?

This substance has 1 hazard statements: H315: Causes skin irritation.

What is the melting point of Potassium standard solution 1000 g/ml (Plasma HIQU)?

The melting point is -3C and the boiling point is 101C.