NextSDS Logo
Ol

Oleic acid

NO SIGNAL WORD Liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Oleic acid
Product Code
O/0200/15, O/0200/17, O/0200/27

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Laboratory chemicals.
Uses Advised Against
No Information available

Overview

Oleic acid is a colorless substance commonly used laboratory chemicals..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Fisher Scientific UK

distributor

๐Ÿ“

Bishop Meadow Road, Loughborough, Leicestershire LE11 5RG, United Kingdom

๐ŸŒ

GB

Acros Organics BVBA

distributor

๐Ÿ“

Janssen Pharmaceuticalaan 3a 2440 Geel, Belgium

๐ŸŒ

BE

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

01509 231166

๐ŸŒ

GB

Chemtrec US

๐Ÿ“ž

(800) 424-9300

๐ŸŒ

US

Chemtrec EU

๐Ÿ“ž

001 (202) 483-7616

๐ŸŒ

US

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

substance

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Oleic acid
EC: 204-007-1
112-80-1 70% โœ“ Non-hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Remove to fresh air. If not breathing, give artificial respiration. Get medical attention if symptoms occur.

๐Ÿ–๏ธ Skin Contact

Wash off immediately with plenty of water for at least 15 minutes. If skin irritation persists, call a physician.

๐Ÿ‘๏ธ Eye Contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.

๐Ÿฝ๏ธ Ingestion/Swallowing

Clean mouth with water and drink afterwards plenty of water.

๐Ÿšจ Immediate Medical Attention Required

Get medical attention for eye contact. Get medical attention if inhalation symptoms occur. If skin irritation persists, call a physician. If symptoms persist, call a physician.

Medical Treatment

Treat symptomatically.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Colorless
๐ŸŽจ Colour
Colorless
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
fatty odor
๐Ÿ“Š Odor Threshold
No data available
๐Ÿงช Ph
No information available
๐ŸงŠ Melting Point
13 C / 55.4 F
Critical Property
๐Ÿ’จ Boiling Point
360 C / 680 F @ 760 mmHg
Critical Property
๐Ÿ”ฅ Flash Point
189 C / 372.2 F
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
No data available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
1 mmHg @ 176 C
๐Ÿ“Š Vapor Density
9.7 (Air = 1.0)
๐Ÿ“Š Relative Density
0.890
๐Ÿ“Š Bulk Density
Not applicable Liquid
โš–๏ธ Density
0.890
Critical Property
๐Ÿ”ฅ Flammability
No data available
๐Ÿ“Š Upper Explosive Limit
No data available
๐Ÿ“Š Lower Explosive Limit
No data available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
363 C / 685.4 F
๐Ÿ“Š Decomposition Temperature
- 80C
๐Ÿ’ง Solubility
No information available
๐Ÿ“Š Partition Coefficient
Oleic acid 7.73
๐Ÿ“Š Solubility In Water
Insoluble
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
282.46
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
39.1 mPa.s at 20 C
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Ensure adequate ventilation, especially in confined areas. Ensure that eyewash stations and safety showers are close to the workstation location. Wherever possible, engineering control measures such as the isolation or enclosure of the process, the introduction of process or equipment changes to minimise release or contact, and the use of properly designed ventilation systems, should be adopted to control hazardous materials at source

๐Ÿงค Hand Protection

Protective gloves Glove material Breakthrough time Glove thickness EU standard Glove comments Butyl rubber See manufacturers - (minimum requirement) Natural rubber Nitrile rubber Neoprene PVC recommendations EN 374 Inspect gloves before use. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. (Refer to manufacturer/supplier for information) Ensure gloves are suitable for the task: Chemical compatability, Dexterity, Operational conditions, User susceptibility, e.g. sensitisation effects, also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion. Remove gloves with care avoiding skin contamination.

๐Ÿ‘๏ธ Eye Protection

Goggles (European standard - EN 166)

๐Ÿ˜ท Respiratory Protection

When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. To protect the wearer, respiratory protective equipment must be the correct fit and be used and maintained properly Large scale/emergency use Use a NIOSH/MSHA or European Standard EN 136 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced Recommended Filter type: Particulates filter conforming to EN 143 or Acid gases filter Type E Yellow conforming to EN14387 Small scale/Laboratory use Use a NIOSH/MSHA or European Standard EN 149:2001 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended half mask:- Valve filtering: EN405; or; Half mask: EN140; plus filter, EN 141 When RPE is used a face piece Fit Test should be conducted

๐Ÿฆบ Skin/Body Protection

Long sleeved clothing.

๐ŸŒ Environmental Exposure Controls

No information available.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Oleic acid?

The signal word for this substance is "no signal word".

What is the physical form of Oleic acid?

Oleic acid is a liquid appearing as colorless with colorless color. It has fatty odor odor.

What is the solubility of Oleic acid?

No information available

What is Oleic acid used for?

Laboratory chemicals.

What is the melting point of Oleic acid?

The melting point is 13 C / 55.4 F and the boiling point is 360 C / 680 F @ 760 mmHg.