Oleic acid

CAS 112-80-1
EC 204-007-1

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Oleic acid
Product Code
O/0200/15, O/0200/17, O/0200/27
Chemical Name
Oleic acid
Synonyms
cis-9-Octadecenoic acid

Regulatory Identifiers

CAS Number
112-80-1 Check regulations →
EC Number
204-007-1 Check regulations →

Identified Uses

Laboratory chemicals.

Uses advised against

No Information available

Manufacturers & Suppliers

F

Fisher Scientific UK

distributor

Bishop Meadow Road, Loughborough, Leicestershire LE11 5RG, United Kingdom

A

Acros Organics BVBA

distributor

Janssen Pharmaceuticalaan 3a, 2440 Geel, Belgium

Emergency Contacts

Fisher Scientific UK

01509 231166

Chemtrec US

(800) 424-9300

Chemtrec EU

001 (202) 483-7616

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
Oleic acid EC: 204-007-1 112-80-1 70% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove to fresh air. If not breathing, give artificial respiration. Get medical attention if symptoms occur.

Skin contact

Wash off immediately with plenty of water for at least 15 minutes. If skin irritation persists, call a physician.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.

Ingestion

Clean mouth with water and drink afterwards plenty of water.

Immediate Medical Attention

Get medical attention for eye contact. Get medical attention if inhalation symptoms occur. If skin irritation persists, call a physician. If symptoms persist, call a physician.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray, carbon dioxide (CO2), dry chemical, alcohol-resistant foam.

Unsuitable media

No information available.

Specific hazards

Thermal decomposition can lead to release of irritating gases and vapors.

Instructions

Keep product and empty container away from heat and sources of ignition.

Firefighter Protection

As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protective equipment as required. Ensure adequate ventilation.

Environmental

Should not be released into the environment.

Cleanup methods

Soak up with inert absorbent material.

Materials: inert absorbent material

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Wear personal protective equipment/face protection. Ensure adequate ventilation. Avoid ingestion and inhalation. Do not get in eyes, on skin, or on clothing.

Storage

Keep container tightly closed in a dry and well-ventilated place. To maintain product quality: Store in freezer. Store under an inert atmosphere.

Hygiene

Handle in accordance with good industrial hygiene and safety practice. Keep away from food, drink and animal feeding stuffs. Do not eat, drink or smoke when using this product. Remove and wash contaminated clothing and gloves, including the inside, before re-use. Wash hands before breaks and after work.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure adequate ventilation, especially in confined areas. Ensure that eyewash stations and safety showers are close to the workstation location. Wherever possible, engineering control measures such as the isolation or enclosure of the process, the introduction of process or equipment changes to minimise release or contact, and the use of properly designed ventilation systems, should be adopted to control hazardous materials at source

Hands

Protective gloves Glove material Breakthrough time Glove thickness EU standard Glove comments Butyl rubber See manufacturers - (minimum requirement) Natural rubber Nitrile rubber Neoprene PVC recommendations EN 374 Inspect gloves before use. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. (Refer to manufacturer/supplier for information) Ensure gloves are suitable for the task: Chemical compatability, Dexterity, Operational conditions, User susceptibility, e.g. sensitisation effects, also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion. Remove gloves with care avoiding skin contamination.

Eyes

Goggles (European standard - EN 166)

Respiratory

When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. To protect the wearer, respiratory protective equipment must be the correct fit and be used and maintained properly Large scale/emergency use Use a NIOSH/MSHA or European Standard EN 136 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced Recommended Filter type: Particulates filter conforming to EN 143 or Acid gases filter Type E Yellow conforming to EN14387 Small scale/Laboratory use Use a NIOSH/MSHA or European Standard EN 149:2001 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended half mask:- Valve filtering: EN405; or; Half mask: EN140; plus filter, EN 141 When RPE is used a face piece Fit Test should be conducted

Skin/Body

Long sleeved clothing.

Environmental

No information available.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Colorless
Colour
Colorless
Colour Intensity
---
Form
---
Odor
fatty odor
Odor Threshold
No data available
Ph
No information available
Melting Point
13 C / 55.4 F
Boiling Point
360 C / 680 F @ 760 mmHg
Flash Point
189 C / 372.2 F
Freezing Point
---
Softening Point
No data available
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
1 mmHg @ 176 C
Vapor Density
9.7 (Air = 1.0)
Relative Density
0.890
Bulk Density
Not applicable Liquid
Density
0.890
Flammability
No data available
Upper Explosive Limit
No data available
Lower Explosive Limit
No data available
Explosive Limits
---
Auto Ignition Temperature
363 C / 685.4 F
Decomposition Temperature
- 80C
Solubility
No information available
Partition Coefficient
Oleic acid 7.73
Solubility In Water
Insoluble
Solubility In Fat
---
Molecular Weight
282.46
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
39.1 mPa.s at 20 C
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1. Toxicity Ecotoxicity effects

Component | Freshwater Fish | Water Flea | Freshwater Algae --- | --- | --- | --- Oleic acid | LC50: = 205 mg/L, 96h static (Pimephales promelas) | |

12.2. Persistence and degradability Persistence

May persist.

The substance may persist in the environment.

12.3. Bioaccumulative potential

Product has a high potential to bioconcentrate | Component | log Pow | Bioconcentration factor (BCF) | | --- | --- | --- | | Oleic acid | 7.73 | 44000 |

Product has a high potential to bioconcentrate

12.4. Mobility in soil

Hydrolyses Spillage unlikely to penetrate soil The product is insoluble and floats on water. Is not likely mobile in the environment due its low water solubility. Is not likely mobile in the environment due its low water solubility and propensity to bind to soil particles

The product is insoluble, floats on water, and is not likely mobile in the environment due to low water solubility and propensity to bind to soil particles.

12.5. Results of PBT and vPvB assessment

No data available for assessment.

No data available for assessment.

12.6. Endocrine disrupting properties

Endocrine Disruptor Information This product does not contain any known or suspected endocrine disruptors

The product does not contain any known or suspected endocrine disruptors.

12.7. Other adverse effects

Persistent Organic Pollutant Ozone Depletion Potential This product does not contain any known or suspected substance This product does not contain any known or suspected substance

The product does not contain any known or suspected substances classified as Persistent Organic Pollutants or having Ozone Depletion Potential.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is Oleic acid known by?

Oleic acid is also known as: cis-9-Octadecenoic acid

What is the hazard signal word for Oleic acid?

The signal word is no signal word.

What is the physical form of Oleic acid?

Oleic acid is a liquid appearing as colorless with colorless color. It has fatty odor odor.

What is the solubility of Oleic acid?

No information available

What is Oleic acid used for?

Laboratory chemicals.

What is the melting point of Oleic acid?

The melting point is 13 C / 55.4 F and the boiling point is 360 C / 680 F @ 760 mmHg.