NextSDS Logo
Safety Data Sheet EN

Oleic acid

CAS 112-80-1
EC 204-007-1

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Oleic acid
Product Code
O/0200/27
Chemical Name
cis-9-Octadecenoic acid
Synonyms
cis-9-Octadecenoic acid

Regulatory Identifiers

CAS Number
112-80-1 Check regulations →
EC Number
204-007-1 Check regulations →

Identified Uses

Laboratory chemicals.

Uses advised against

No Information available

Manufacturers & Suppliers

F

Fisher Scientific UK

distributor

Bishop Meadow Road, Loughborough, Leicestershire LE11 5RG, United Kingdom

A

Acros Organics BVBA

distributor

Janssen Pharmaceuticalaan 3a 2440 Geel, Belgium

Emergency Contacts

Emergency Contact

01509 231166

Chemtrec US

(800) 424-9300

Chemtrec EU

001 (202) 483-7616

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
cis-9-Octadecenoic acid EC: 204-007-1 112-80-1 70% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove to fresh air. If not breathing, give artificial respiration. Get medical attention if symptoms occur.

Skin contact

Wash off immediately with plenty of water for at least 15 minutes. If skin irritation persists, call a physician.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.

Ingestion

Clean mouth with water and drink afterwards plenty of water.

Immediate Medical Attention

Get medical attention for eye contact. Get medical attention if inhalation symptoms occur. If skin irritation persists, call a physician. If symptoms persist, call a physician.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure adequate ventilation, especially in confined areas. Ensure that eyewash stations and safety showers are close to the workstation location. Wherever possible, engineering control measures such as the isolation or enclosure of the process, the introduction of process or equipment changes to minimise release or contact, and the use of properly designed ventilation systems, should be adopted to control hazardous materials at source

Hands

Protective gloves Glove material Breakthrough time Glove thickness EU standard Glove comments Butyl rubber See manufacturers - (minimum requirement) Natural rubber Nitrile rubber Neoprene PVC recommendations EN 374 Inspect gloves before use. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. (Refer to manufacturer/supplier for information) Ensure gloves are suitable for the task: Chemical compatability, Dexterity, Operational conditions, User susceptibility, e.g. sensitisation effects, also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion. Remove gloves with care avoiding skin contamination.

Eyes

Goggles (European standard - EN 166)

Respiratory

When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. To protect the wearer, respiratory protective equipment must be the correct fit and be used and maintained properly Large scale/emergency use Use a NIOSH/MSHA or European Standard EN 136 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced Recommended Filter type: Particulates filter conforming to EN 143 or Acid gases filter Type E Yellow conforming to EN14387 Small scale/Laboratory use Use a NIOSH/MSHA or European Standard EN 149:2001 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended half mask:- Valve filtering: EN405; or; Half mask: EN140; plus filter, EN 141 When RPE is used a face piece Fit Test should be conducted

Skin/Body

Long sleeved clothing.

Environmental

No information available.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Colorless
Colour
Colorless
Colour Intensity
---
Form
---
Odor
fatty odor
Odor Threshold
No data available
Ph
No information available
Melting Point
13 C / 55.4 F
Boiling Point
360 C / 680 F @ 760 mmHg
Flash Point
189 C / 372.2 F
Freezing Point
---
Softening Point
No data available
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
1 mmHg @ 176 C
Vapor Density
9.7 (Air = 1.0)
Relative Density
0.890
Bulk Density
Not applicable Liquid
Density
0.890
Flammability
No data available
Upper Explosive Limit
No data available
Lower Explosive Limit
No data available
Explosive Limits
---
Auto Ignition Temperature
363 C / 685.4 F
Decomposition Temperature
- 80C
Solubility
No information available
Partition Coefficient
Oleic acid 7.73
Solubility In Water
Insoluble
Solubility In Fat
---
Molecular Weight
282.46
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
39.1 mPa.s at 20 C
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is Oleic acid known by?

Oleic acid is also known as: cis-9-Octadecenoic acid

What is the hazard signal word for Oleic acid?

The signal word is no signal word.

What is the physical form of Oleic acid?

Oleic acid is a liquid appearing as colorless with colorless color. It has fatty odor odor.

What is the solubility of Oleic acid?

No information available

What is Oleic acid used for?

Laboratory chemicals.

What is the melting point of Oleic acid?

The melting point is 13 C / 55.4 F and the boiling point is 360 C / 680 F @ 760 mmHg.

Compliance Scanner