01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Oleic acid
Product Code
O1383

Regulatory Identifiers

CAS Number
112-80-1 Check regulations →
REACH No.
A registration number is not available for this substance as the substance or its uses are exempted from registration, the annual tonnage does not require a registration or the registration is envisaged for a later registration deadline.

Identified Uses

Laboratory chemicals, Manufacture of substances

Manufacturers & Suppliers

S

Sigma-Aldrich BVBA/SPRL

manufacturer

Pegasuslaan 5, B-1831 DIEGEM

+32 3 899 1301

Emergency Contacts

Emergency Contact

070 245245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Skin Irrit. Cat. 2 H315

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H315 Causes skin irritation.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
Oleic acid EC: 204-007-1 112-80-1 100% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.

Skin contact

Wash off with soap and plenty of water. Consult a physician.

Eye contact

Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.

Ingestion

Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.

Specific hazards

Carbon oxides

Firefighter Protection

Wear self contained breathing apparatus for fire fighting if necessary.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protective equipment. Avoid breathing vapours, mist or gas. Ensure adequate ventilation.

Environmental

Do not let product enter drains.

Cleanup methods

Soak up with inert absorbent material and dispose of as hazardous waste.

Materials: inert absorbent material

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid contact with skin and eyes. Avoid inhalation of vapour or mist.

Storage

Store in cool place. Keep container tightly closed in a dry and well-ventilated place.

Fire prevention

Normal measures for preventive fire protection.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it. Full contact Material: Nitrile rubber Minimum layer thickness: 0,4 mm Break through time: 480 min Material tested:Camatril® (KCL 730 / Aldrich Z677442, Size M) Splash contact Material: Nitrile rubber Minimum layer thickness: 0,2 mm Break through time: 30 min Material tested:Dermatril® P (KCL 743 / Aldrich Z677388, Size M) data source: KCL GmbH, D-36124 Eichenzell, phone +49 (0)6659 87300, e-mail sales@kcl.de, test method: EN374 If used in solution, or mixed with other substances, and under conditions which differ from EN 374, contact the supplier of the CE approved gloves. This recommendation is advisory only and must be evaluated by an industrial hygienist and safety officer familiar with the specific situation of anticipated use by our customers. It should not be construed as offering an approval for any specific use scenario.

Eyes

Safety glasses with side-shields conforming to EN166 Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).

Respiratory

Where risk assessment shows air-purifying respirators are appropriate use a full-face respirator with multi-purpose combination (US) or type ABEK (EN 14387) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).

Skin/Body

impervious clothing, The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.

Environmental

Do not let product enter drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Form: liquid, clear Colour: colourless
Colour
colourless
Colour Intensity
---
Form
liquid
Odor
no data available
Odor Threshold
no data available
Ph
no data available
Melting Point
13 - 14 °C - lit.
Boiling Point
194 - 195 °C at 1,6 hPa - lit.
Flash Point
113 °C - closed cup
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
no data available
Vapor Pressure
1 hPa at 176 °C
Vapor Density
no data available
Relative Density
0,89 g/cm3 at 25 °C
Bulk Density
---
Density
---
Flammability
no data available
Upper Explosive Limit
no data available
Lower Explosive Limit
no data available
Explosive Limits
---
Auto Ignition Temperature
no data available
Decomposition Temperature
no data available
Solubility
---
Partition Coefficient
no data available
Solubility In Water
no data available
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
no data available
Kinematic Viscosity
no data available
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended storage conditions.

Reactivity

no data available

Hazardous reactions

no data available

Avoid

no data available

Incompatible

Strong oxidizing agents

Decomposition

Other decomposition products - no data available. In the event of fire: see section 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

12.1 Toxicity

12.1 Toxicity

Toxicity to fish LC50 - Pimephales promelas (fathead minnow) - 205 mg/l - 96 h

12.2 Persistence and degradability

no data available

12.3 Bioaccumulative potential

no data available

12.4 Mobility in soil

no data available

12.5 Results of PBT and vPvB assessment

PBT/vPvB assessment not available as chemical safety assessment not required/not conducted

12.6 Other adverse effects

no data available
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Offer surplus and non-recyclable solutions to a licensed disposal company. Contact a licensed professional waste disposal service to dispose of this material.

Disposal

Offer surplus and non-recyclable solutions to a licensed disposal company. Contact a licensed professional waste disposal service to dispose of this material.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

Shipping Name
Not dangerous goods
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

no data available

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Oleic acid?

The signal word is warning.

What is the physical form of Oleic acid?

Oleic acid is a liquid appearing as form: liquid, clear colour: colourless with colourless color. It has no data available odor.

What is Oleic acid used for?

Laboratory chemicals, Manufacture of substances

What are the hazard statements for Oleic acid?

This substance has 1 hazard statement:

  • H315: Causes skin irritation.

What is the melting point of Oleic acid?

The melting point is 13 - 14 °C - lit. and the boiling point is 194 - 195 °C at 1,6 hPa - lit..