NextSDS Logo
Hy

Hydrochloric acid, 1.0N Standardized Solution

DANGER Liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Hydrochloric acid, 1.0N Standardized Solution
Product Code
35640

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

UFI Code
6ACQ-4W9Y-GU10-65DG

Unique Formula Identifier - for poison centres and emergency response

Uses Information

Identified Uses
Laboratory chemicals.
Uses Advised Against
No Information available

Overview

Hydrochloric acid, 1.0N Standardized Solution is a colorless substance commonly used laboratory chemicals..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Met. Corr. Category 1 H290
Skin Irr. Category 2 H315
Eye Dam. Category 1 H318

GHS Hazard Pictograms & Safety Symbols

GHS05 GHS Hazard Pictogram: Corrosive hazard - Materials that can cause severe skin burns and eye damage

GHS05

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H290: May be corrosive to metals
  • H315: Causes skin irritation
  • H318: Causes serious eye damage

Precautionary Statements

  • IF ON SKIN: Wash with plenty of soap and water
  • IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing
  • P310: Immediately call a POISON CENTER or doctor/physician
  • P280: Wear protective gloves/protective clothing/eye protection/face protection

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Thermo Fisher (Kandel) GmbH

manufacturer

๐Ÿ“

Erlenbachweg 2, 76870 Kandel, Germany

๐ŸŒ

DE

๐Ÿ“ž

+49 (0) 721 84007 280

๐Ÿ“ 

+49 (0) 721 84007 300

Fisher Scientific AG company logo - Safety Data Sheet supplier organization

Fisher Scientific AG

distributor

๐Ÿ“

Neuhofstrasse 11, CH 4153 Reinach

๐ŸŒ

CH

๐Ÿ“ž

+41 (0) 56 618 41 11

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

001-800-227-6701

๐ŸŒ

US

๐Ÿ’ก

For information

Emergency Contact

๐Ÿ“ž

+32 14 57 52 11

๐ŸŒ

BE

๐Ÿ’ก

For information

Emergency Contact

๐Ÿ“ž

001-201-796-7100

๐ŸŒ

US

Emergency Contact

๐Ÿ“ž

+32 14 57 52 99

๐ŸŒ

BE

CHEMTREC

๐Ÿ“ž

001-800-424-9300

๐ŸŒ

US

CHEMTREC

๐Ÿ“ž

001-703-527-3887

๐ŸŒ

US

Tox Info Suisse

๐Ÿ“ž

145

๐ŸŒ

CH

๐Ÿ•’

24hr

Tox Info Suisse

๐Ÿ“ž

+41-44 251 51 51

๐ŸŒ

CH

๐Ÿ’ก

from abroad

Chemtrec

๐Ÿ“ž

0800 564 402

๐ŸŒ

CH

๐Ÿ•’

24h

๐Ÿ’ก

Toll-Free

Chemtrec

๐Ÿ“ž

+41-43 508 20 11

๐ŸŒ

CH

๐Ÿ’ก

Local (Zurich)

National Poisons Information Centre (NPIC)

๐Ÿ“ž

01 809 2166

๐ŸŒ

IE

๐Ÿ•’

8am-10pm, 7 days a week

Poison Centre - Emergency information services

๐Ÿ“ž

+356 2395 2000

๐ŸŒ

MT

Poison Centre - Emergency information services

๐Ÿ“ž

+357 2240 5611

๐ŸŒ

CY

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Water
EC: 231-791-2
7732-18-5 90-99% โœ“ Non-hazardous
Hydrochloric acid
EC: 231-595-7
7647-01-0 1-10% โš ๏ธ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Remove to fresh air. If not breathing, give artificial respiration. Get medical attention if symptoms occur.

๐Ÿ–๏ธ Skin Contact

Wash off immediately with plenty of water for at least 15 minutes. If skin irritation persists, call a physician.

๐Ÿ‘๏ธ Eye Contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.

Symptoms:

Causes severe eye damage.

๐Ÿฝ๏ธ Ingestion/Swallowing

Clean mouth with water and drink afterwards plenty of water.

๐Ÿšจ Immediate Medical Attention Required

Get medical attention. If symptoms persist, call a physician. If skin irritation persists, call a physician.

Medical Treatment

Treat symptomatically.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Colorless
๐ŸŽจ Colour
Colorless
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Odorless
๐Ÿ“Š Odor Threshold
No data available
๐Ÿงช Ph
No information available
๐ŸงŠ Melting Point
No data available
Critical Property
๐Ÿ’จ Boiling Point
100 - 103 C / 212 - 217.4 F
Critical Property
๐Ÿ”ฅ Flash Point
Not applicable
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
No data available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
No data available
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
1.00-1.05
๐Ÿ“Š Bulk Density
Not applicable Liquid
โš–๏ธ Density
1.00-1.05
Critical Property
๐Ÿ”ฅ Flammability
No data available
๐Ÿ“Š Upper Explosive Limit
No data available
๐Ÿ“Š Lower Explosive Limit
No data available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
No data available
๐Ÿ“Š Decomposition Temperature
No data available
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
No data available
๐Ÿ“Š Solubility In Water
Miscible
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
No data available
๐Ÿ“Š Kinematic Viscosity
No data available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Ensure adequate ventilation, especially in confined areas. Wherever possible, engineering control measures such as the isolation or enclosure of the process, the introduction of process or equipment changes to minimise release or contact, and the use of properly designed ventilation systems, should be adopted to control hazardous materials at source

๐Ÿงค Hand Protection

Protective gloves. Inspect gloves before use. observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. (Refer to manufacturer/supplier for information) gloves are suitable for the task: Chemical compatability, Dexterity, Operational conditions, User susceptibility, e.g., sensitisation effects, also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion. gloves with care avoiding skin contamination.

๐Ÿ‘๏ธ Eye Protection

Goggles (European standard - EN 166)

๐Ÿ˜ท Respiratory Protection

Follow the OSHA respirator regulations found in 29 CFR 1910.134 or European Standard EN 149. Use a NIOSH/MSHA or European Standard EN 149 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. To protect the wearer, respiratory protective equipment must be the correct fit and be used and maintained properly. Large scale/emergency use: Use a NIOSH/MSHA or European Standard EN 136 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended Filter type: Particulates filter conforming to EN 143. Small scale/Laboratory use: No personal respiratory protective equipment normally required. When RPE is used a face piece Fit Test should be conducted

๐Ÿฆบ Skin/Body Protection

Wear appropriate protective gloves and clothing to prevent skin exposure.

๐ŸŒ Environmental Exposure Controls

No information available.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

UN1789

๐Ÿ“ฆ Proper Shipping Name

HYDROCHLORIC ACID, SOLUTION

โš ๏ธ Transport Hazard Class

8

๐Ÿ“‹ Packing Group

III

๐Ÿš› ADR Transport Precautions

No special precautions required.

๐Ÿšข IMDG Maritime Transport Precautions

No special precautions required.

โœˆ๏ธ IATA Air Transport Precautions

No special precautions required.

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Hydrochloric acid, 1.0N Standardized Solution?

The signal word for this substance is "danger".

What is the physical form of Hydrochloric acid, 1.0N Standardized Solution?

Hydrochloric acid, 1.0N Standardized Solution is a liquid appearing as colorless with colorless color. It has odorless odor.

What is Hydrochloric acid, 1.0N Standardized Solution used for?

Laboratory chemicals.

What are the hazard statements for Hydrochloric acid, 1.0N Standardized Solution?

This substance has 3 hazard statements: H290: May be corrosive to metals H315: Causes skin irritation H318: Causes serious eye damage

What is the melting point of Hydrochloric acid, 1.0N Standardized Solution?

The melting point is No data available and the boiling point is 100 - 103 C / 212 - 217.4 F.