NextSDS Logo
Safety Data Sheet EN

ICP solvent

CAS 64742-47-8

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
ICP solvent
Product Code
54362

Regulatory Identifiers

CAS Number
64742-47-8 Check regulations →
REACH No.
A registration number is not available for this substance as the substance or its uses are exempted from registration, the annual tonnage does not require a registration or the registration is envisaged for a later registration deadline.

Identified Uses

Laboratory chemicals, Manufacture of substances

Manufacturers & Suppliers

M

Merck Life Science BV/SRL

manufacturer

Brusselsesteenweg 288, B-3090 OVERIJSE

+32 (0)3 899-1301

Emergency Contacts

CHEMTREC

+(32) 28 083237

Anti-poison centre

070 245245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Asp. Tox. Cat. 1 H304

GHS Pictograms

GHS08 - Serious health hazard

GHS08

Hazard Statements

H304 May be fatal if swallowed and enters airways.

Precautionary Statements

P301 + P310 IF SWALLOWED: Immediately call a POISON CENTER/ doctor.
P331 Do NOT induce vomiting.
P405 Store locked up.
P501 Dispose of contents/ container to an approved waste disposal plant.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
Distillates (petroleum), hydrotrated light, kerosene EC: 265-149-8 64742-47-8 100% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

After inhalation: fresh air.

Skin contact

In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/ shower.

Eye contact

After eye contact: rinse out with plenty of water. Remove contact lenses.

Ingestion

Call a physician immediately.

Symptoms: caution if victim vomits. Risk of aspiration! Keep airways free. Pulmonary failure possible after aspiration of vomit.

Immediate Medical Attention

No data available

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Eyes

Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses

Respiratory

required when vapours/aerosols are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system. Recommended Filter type: Filter type ABEK The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

Skin/Body

required protective clothing

Environmental

Do not let product enter drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Metal Corrosion
---
Decomposition Temperature
No data available
Colour Intensity
---
Softening Point
---
Physical State Data
liquid
Vapor Pressure
0,4 hPa
Melting Point
0 C at 1.013 hPa - ISO 3016
Voc Content
---
Odor Threshold
---
Form
---
Partition Coefficient
log Pow: 6,0 - 8,2
Solubility
---
Upper Explosive Limit
6 %(V)
Ph
No data available
Crystallisation Point
---
Boiling Point
218 - 800 C at 1.013 hPa
Cloud Point
---
Auto Ignition Temperature
325 - 355 C - ASTM E-659
Density
0,82 g/cm3
Appearance
---
Solidification Point
---
Evaporation Rate
---
Solubility In Water
No data available
Properties Status
---
Solubility In Fat
---
State Under Standard Conditions
---
Molecular Weight
---
Odor
odorless
Explosive Limits
---
Vapor Density
---
Flammability
No data available
Kinematic Viscosity
> 3 mm2/s at 40 C - ISO 3219
Physical State
liquid
Colour
colorless
Flash Point
70 C
Freezing Point
---
Relative Density
No data available
Lower Explosive Limit
0,6 %(V)
Relative Evaporation Rate
---
Dynamic Viscosity
No data available
Bulk Density
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for ICP solvent?

The signal word is danger.

What is the physical form of ICP solvent?

ICP solvent is a liquid with colorless color. It has odorless odor.

What is ICP solvent used for?

Laboratory chemicals, Manufacture of substances

What are the hazard statements for ICP solvent?

This substance has 1 hazard statement:

  • H304: May be fatal if swallowed and enters airways.

What is the melting point of ICP solvent?

The melting point is 0 C at 1.013 hPa - ISO 3016 and the boiling point is 218 - 800 C at 1.013 hPa.