NextSDS Logo
IC

ICP solvent

DANGER liquid SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
ICP solvent
Product Code
54362
Chemical Name
Light Hydrotreated Distillate

Regulatory Identifiers

CAS Number

Chemical Abstracts Service registry number - unique identifier for chemical substances

EC Number

European Community number - used for regulatory compliance in EU/EEA

Uses Information

Identified Uses
Laboratory chemicals, Manufacture of substances

Overview

ICP solvent (CAS: 64742-47-8 ) commonly used laboratory chemicals, manufacture of substances.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Asp. Tox. Category 1 H304

GHS Hazard Pictograms & Safety Symbols

GHS08 GHS Hazard Pictogram: Serious health hazard - Carcinogenic, mutagenic, or toxic to organs

GHS08

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H304: May be fatal if swallowed and enters airways.

Precautionary Statements

  • P301 + P310: IF SWALLOWED: Immediately call a POISON CENTER/ doctor.
  • P331: Do NOT induce vomiting.
  • P405: Store locked up.
  • P501: Dispose of contents/ container to an approved waste disposal plant.
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Merck Life Science BV/SRL

national supplier

Brusselsesteenweg 288 B-3090 OVERIJSE

BE

+32 (0)3 899-1301

+32 (0)3 899-1311

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

CHEMTREC

+(32) 28 083237

BE

Anti-poison centre

070 245245

BE

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

substance

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Distillates (petroleum), hydrotrated light, kerosene
EC: 265-149-8
64742-47-8 100% Hazardous
First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

After inhalation: fresh air.

Skin Contact

In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/ shower.

Eye Contact

After eye contact: rinse out with plenty of water. Remove contact lenses.

Ingestion/Swallowing

Call a physician immediately.

Symptoms:

caution if victim vomits. Risk of aspiration! Keep airways free. Pulmonary failure possible after aspiration of vomit.

Immediate Medical Attention Required

No data available

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Physical State
liquid
Critical Property
Physical State Data
liquid
State Under Standard Conditions
Not available
Appearance
Not available
Colour
colorless
Colour Intensity
Not available
Form
Not available
Odor
odorless
Odor Threshold
Not available
Ph
No data available
Melting Point
0 C at 1.013 hPa - ISO 3016
Critical Property
Boiling Point
218 - 800 C at 1.013 hPa
Critical Property
Flash Point
70 C
Critical Property
Freezing Point
Not available
Softening Point
Not available
Solidification Point
Not available
Cloud Point
Not available
Crystallisation Point
Not available
Relative Evaporation Rate
Not available
Evaporation Rate
Not available
Vapor Pressure
0,4 hPa
Vapor Density
Not available
Relative Density
No data available
Bulk Density
Not available
Density
0,82 g/cm3
Critical Property
Flammability
No data available
Upper Explosive Limit
6 %(V)
Lower Explosive Limit
0,6 %(V)
Explosive Limits
Not available
Auto Ignition Temperature
325 - 355 C - ASTM E-659
Decomposition Temperature
No data available
Solubility
Not available
Partition Coefficient
log Pow: 6,0 - 8,2
Solubility In Water
No data available
Solubility In Fat
Not available
Molecular Weight
Not available
Voc Content
Not available
Metal Corrosion
Not available
Dynamic Viscosity
No data available
Kinematic Viscosity
> 3 mm2/s at 40 C - ISO 3219
Properties Status
Not available
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Eye Protection

Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses

Respiratory Protection

required when vapours/aerosols are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system. Recommended Filter type: Filter type ABEK The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

Skin/Body Protection

required protective clothing

Environmental Exposure Controls

Do not let product enter drains.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for ICP solvent?

The signal word for this substance is "danger".

What is the physical form of ICP solvent?

ICP solvent is a liquid with colorless color. It has odorless odor.

What is ICP solvent used for?

Laboratory chemicals, Manufacture of substances

What are the hazard statements for ICP solvent?

This substance has 1 hazard statements: H304: May be fatal if swallowed and enters airways.

What is the melting point of ICP solvent?

The melting point is 0 C at 1.013 hPa - ISO 3016 and the boiling point is 218 - 800 C at 1.013 hPa.