Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Multi Element ICP Standard sol. (22E)
- Product Code
- CL01.39160
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Reagent for analysis
Manufacturers & Suppliers
AnalytiChem Belgium NV
manufacturer
Industriezone "De Arend" 2, B-8210 ZEDELGEM - BELGIUM
(32)-50-288320
Emergency Contacts
Emergency Contact
00 (32) 50.28.83.20
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
GHS07
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Hydrochloric acid 34- 37% (Pico-Pure) | 7647-01-0 | 10 - 15% | Yes |
| Nitric acid 67 - 69% (Pico-Pure) | 7697-37-2 | 10 - 15% | Yes |
| Hydrofluoric acid 47 - 51% (Pico-Pure) | 7664-39-3 | 0.1% | Yes |
For the full text of H-Phrases mentioned in this Section, see Section 16.
First Aid Measures
Emergency procedures for chemical exposure incidents
Fresh air. If breathing stops immediately apply mechanical ventilation, if necessary oxygen mask. Immediately call in physician.
Wash off with plenty of water. Dab with polyethylene glycol 400. Remove contaminated clothing. Immediately call in physician.
Rinse out with plenty of water for at least 10 minutes with the eyelid held wide open. Immediately call an ophthalmologist.
Never give anything by mouth to an unconscious person. Make victim drink plenty of water. Avoid vomiting. Keep airways free. Call in physician.
Symptoms: In case of spontaneous vomiting, risk of aspiration. Pulmonary failure possible.
Immediate Medical Attention
Immediately call in physician.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
In adaption to materials stored in the immediate neighbourhood.
Prevent fire-fighting water from entering surface water or groundwater.
Non-combustible. Ambient fire may liberate hazardous vapours.
Do not stay in dangerous zone without self-contained breathing apparatus. In order to avoid contact with skin, keep a safety distance and wear suitable protective clothing.
Firefighter Protection
Do not stay in dangerous zone without self-contained breathing apparatus. In order to avoid contact with skin, keep a safety distance and wear suitable protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not inhale vapours/aerosols. Avoid substance contact. Ensure supply of fresh air in enclosed rooms.
Do not allow to enter sewerage system.
Absorb on vermiculite, sand or a pillow from Chemical Spill Center.
Materials: vermiculite, sand, pillow from Chemical Spill Center
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid all contact, do not inhale gas/fume/vapour/spray. For precautions see section 2.2
Closed in a cool ventilated place. Recommended storage temperature see product label.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Protective clothing should be selected specifically for the working place, depending on concentration and quantity of the hazardous substances handled. The resistance of the protective clothing to chemicals should be ascertained with the respective supplier. See section 7.1. Work under hood.
Required.
Required.
Required when vapours/aerosols are generated. The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.
Required.
Do not allow to enter sewerage system.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No further relevant information available.
See section 10.3
Dangerous reactions are not expected handling the product according to its intended use.
No further relevant information available.
No further relevant information available.
No further relevant information available.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxity
No further relevant information available.
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
No further relevant information available.
12.5 Results of PBT and vPvB assessment
12.6 Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Chemicals must be disposed of in compliance with the respective national regulations.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3264
- Shipping Name
- Corrosive liquid, acidic, inorganic, n.o.s. (Hydrochloric acid - Nitric acid solution)
- Transport Class
- 8
- Packing Group
- III
no
no
no
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Multi Element ICP Standard sol. (22E)?
The signal word is danger.
What is the physical form of Multi Element ICP Standard sol. (22E)?
Multi Element ICP Standard sol. (22E) is a liquid appearing as liquid, yellow, odourless with yellow color. It has odourless odor.
What is Multi Element ICP Standard sol. (22E) used for?
Reagent for analysis
What are the hazard statements for Multi Element ICP Standard sol. (22E)?
This substance has 4 hazard statements:
- H290: May be corrosive to metals.
- H314: Causes severe skin burns and eye damage.
- H315: Causes skin irritation.
- H335: May cause respiratory irritation.
What is the melting point of Multi Element ICP Standard sol. (22E)?