Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Iodine solution according to Wijs
- Product Code
- 270570000; 270570010; 270570025
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Laboratory chemicals.
Uses advised against
No Information available
Manufacturers & Suppliers
Fisher Scientific UK
distributor
Bishop Meadow Road, Loughborough, Leicestershire LE11 5RG, United Kingdom
Thermo Fisher Scientific
distributor
Janssen Pharmaceuticalaan 3a, 2440 Geel, Belgium
Emergency Contacts
Emergency Contact
001-800-227-6701
Emergency Contact
+32 14 57 52 11
Emergency Contact
001-201-796-7100
Emergency Contact
+32 14 57 52 99
CHEMTREC
001-800-424-9300
CHEMTREC
001-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS05
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
If not breathing, give artificial respiration. Remove from exposure, lie down. Do not use mouth-to-mouth method if victim ingested or inhaled the substance; give artificial respiration with the aid of a pocket mask equipped with a one-way valve or other proper respiratory medical device.
Wash off immediately with plenty of water for at least 15 minutes. Remove and wash contaminated clothing and gloves, including the inside, before re-use.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes.
Do NOT induce vomiting. Clean mouth with water. Never give anything by mouth to an unconscious person.
Symptoms: Ingestion causes severe swelling, severe damage to the delicate tissue and danger of perforation
Immediate Medical Attention
Immediate medical attention is required. Call a physician immediately.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Carbon dioxide (CO₂). Dry chemical. Chemical foam. Water mist may be used to cool closed containers. CO₂, dry chemical, dry sand, alcohol-resistant foam.
No information available.
Thermal decomposition can lead to release of irritating gases and vapors. The product causes burns of eyes, skin and mucous membranes. Flammable. Containers may explode when heated. Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back.
Firefighter Protection
Wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Ensure adequate ventilation. Use personal protective equipment as required. Evacuate personnel to safe areas. Keep people away from and upwind of spill/leak.
Should not be released into the environment.
Keep in suitable, closed containers for disposal.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Wear personal protective equipment/face protection. Do not get in eyes, on skin, or on clothing. Use only under a chemical fume hood. Do not breathe mist/vapors/spray. Do not ingest. If swallowed then seek immediate medical assistance. Keep away from open flames, hot surfaces and sources of ignition. Use only non-sparking tools. Take precautionary measures against static discharges.
Keep containers tightly closed in a dry, cool and well-ventilated place.
Handle in accordance with good industrial hygiene and safety practice. Keep away from food, drink and animal feeding stuffs. Do not eat, drink or smoke when using this product. Remove and wash contaminated clothing and gloves, including the inside, before re-use. Wash hands before breaks and after work.
Keep away from open flames, hot surfaces and sources of ignition. Use only non-sparking tools. Take precautionary measures against static discharges.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use explosion-proof electrical/ventilating/lighting equipment. Ensure that eyewash stations and safety showers are close to the workstation location. Use only under a chemical fume hood. Ensure adequate ventilation, especially in confined areas. Wherever possible, engineering control measures such as the isolation or enclosure of the process, the introduction of process or equipment changes to minimise release or contact, and the use of properly designed ventilation systems, should be adopted to control hazardous materials at source
Protective gloves. Glove material: Butyl rubber. Breakthrough time: See manufacturers recommendations. Glove thickness: -. EU standard: EN 374. Glove comments: (minimum requirement).
Goggles (European standard - EN 166)
When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. Large scale/emergency use: Use a NIOSH/MSHA or European Standard EN 136 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Small scale/Laboratory use: Maintain adequate ventilation
Long sleeved clothing.
Prevent product from entering drains.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
None known, based on information available
None under normal processing. Hazardous Polymerization: No information available.
Keep away from open flames, hot surfaces and sources of ignition. Incompatible products. Exposure to moist air or water.
Strong oxidizing agents. Metals. Finely powdered metals.
Carbon monoxide (CO). Carbon dioxide (CO₂). Hydrogen iodide. Hydrogen chloride gas.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1. Toxicity
12.2. Persistence and degradability
Persistence is unlikely. Contains substances known to be hazardous to the environment or not degradable in waste water treatment plants.
12.3. Bioaccumulative potential
Bioaccumulation is unlikely.
12.3. Bioaccumulative potential
12.4. Mobility in soil
12.5. Results of PBT and vPvB assessment
12.6. Endocrine disrupting properties
12.7. Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Dispose of in accordance with the European Directives on waste and hazardous waste. Dispose of in accordance with local regulations.
Dispose of in accordance with the European Directives on waste and hazardous waste. Dispose of in accordance with local regulations.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN2920
- Shipping Name
- Corrosive liquid, flammable, n.o.s.
- Transport Class
- 8
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Iodine solution according to Wijs?
The signal word is danger.
What is the physical form of Iodine solution according to Wijs?
Iodine solution according to Wijs is a liquid appearing as brown . It has odorless odor.
What is the solubility of Iodine solution according to Wijs?
No information available
What is Iodine solution according to Wijs used for?
Laboratory chemicals.
What are the hazard statements for Iodine solution according to Wijs?
This substance has 2 hazard statements:
- H226: Flammable liquid and vapor
- H314: Causes severe skin burns and eye damage
What is the melting point of Iodine solution according to Wijs?
The melting point is No data available and the boiling point is No information available.