NextSDS Logo
In

Incidin OxyFoam S

NO SIGNAL WORD liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Incidin OxyFoam S
Product Code
116307E

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Surface Disinfectant. Surface disinfectant. Manual process
Uses Advised Against
Reserved for industrial and professional use.

Overview

Incidin OxyFoam S is a liquid substance commonly used surface disinfectant. surface disinfectant. manual process.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

Hazard Classifications

Not Classified

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Ecolab Ltd.

undefined

๐Ÿ“

PO Box 11; Winnington Avenue Northwich, Cheshire, United Kingdom CW8 4DX

๐ŸŒ

GB

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Ecolab Ltd.

๐Ÿ“ž

+44 (0)1606 74488

๐ŸŒ

GB

๐Ÿ’ก

Food & Beverage, Institutional, Agriculture, Textile Hygiene

Ecolab Ltd.

๐Ÿ“ž

+44 (0)113 232 2480

๐ŸŒ

GB

๐Ÿ’ก

Healthcare Leeds

Ecolab Ltd.

๐Ÿ“ž

+44 (0)1235 239670

๐ŸŒ

GB

๐Ÿ’ก

Healthcare Swansea

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Hydrogen peroxide
EC: 231-765-0
7722-84-1 1-2.5% โš ๏ธ Hazardous
Glycolic acid
EC: 201-180-5
79-14-1 1-2.5% โš ๏ธ Hazardous

Composition Notes

For the full text of the H-Statements mentioned in this Section, see Section 16.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Get medical attention if symptoms occur.

๐Ÿ–๏ธ Skin Contact

Rinse with plenty of water.

๐Ÿ‘๏ธ Eye Contact

Rinse with plenty of water.

๐Ÿฝ๏ธ Ingestion/Swallowing

Rinse mouth. Get medical attention if symptoms occur.

Medical Treatment

No specific measures identified.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
liquid
๐ŸŽจ Colour
clear, colourless
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
characteristic
๐Ÿ“Š Odor Threshold
Not applicable and/or not determined for the mixture
๐Ÿงช Ph
2.01 - 2.11, 100 %
๐ŸงŠ Melting Point
Not applicable and/or not determined for the mixture
Critical Property
๐Ÿ’จ Boiling Point
100 ยฐC
Critical Property
๐Ÿ”ฅ Flash Point
Not applicable., Does not sustain combustion.
Critical Property
๐Ÿ“Š Freezing Point
Not applicable and/or not determined for the mixture
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not applicable and/or not determined for the mixture
๐Ÿ’จ Vapor Pressure
Not applicable and/or not determined for the mixture
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
1.01 - 1.016
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not available
๐Ÿ”ฅ Flammability
Not applicable and/or not determined for the mixture
๐Ÿ“Š Upper Explosive Limit
Not applicable and/or not determined for the mixture
๐Ÿ“Š Lower Explosive Limit
Not applicable and/or not determined for the mixture
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Not applicable and/or not determined for the mixture
๐Ÿ“Š Decomposition Temperature
Not applicable and/or not determined for the mixture
๐Ÿ’ง Solubility
Not applicable and/or not determined for the mixture
๐Ÿ“Š Partition Coefficient
Not applicable and/or not determined for the mixture
๐Ÿ“Š Solubility In Water
soluble
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not applicable and/or not determined for the mixture
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Good general ventilation should be sufficient to control worker exposure to airborne contaminants.

๐Ÿงค Hand Protection

No special protective equipment required.

๐Ÿ‘๏ธ Eye Protection

No special protective equipment required.

๐Ÿ˜ท Respiratory Protection

None required if airborne concentrations are maintained below the exposure limit listed in Exposure Limit Information. Use certified respiratory protection equipment meeting EU requirements(89/656/EEC, 89/686/EEC ), or equivalent, when respiratory risks cannot be avoided or sufficiently limited by technical means of collective protection or by measures, methods or procedures of work organization.

๐Ÿฆบ Skin/Body Protection

No special protective equipment required.

๐ŸŒ Environmental Exposure Controls

Consider the provision of containment around storage vessels.

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

โœ… Chemical Stability

Stable under normal conditions.

โš—๏ธ Reactivity

No dangerous reaction known under conditions of normal use.

โš ๏ธ Hazardous Reactions

Do not mix with bleach or other chlorinated products โ€“ will cause chlorine gas.

๐Ÿšซ Conditions to Avoid

None known.

๐Ÿงช Incompatible Materials

None known.

๐Ÿ’จ Hazardous Decomposition Products

Decomposition products may include the following materials: Carbon oxides nitrogen oxides (NOx) Sulphur oxides Oxides of phosphorus

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

Not dangerous goods

๐Ÿ“ฆ Proper Shipping Name

Not dangerous goods

โš ๏ธ Transport Hazard Class

Not dangerous goods

๐Ÿ“‹ Packing Group

Not dangerous goods

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Incidin OxyFoam S?

The signal word for this substance is "no signal word".

What is the physical form of Incidin OxyFoam S?

Incidin OxyFoam S is a liquid appearing as liquid with clear, colourless color. It has characteristic odor.

What is the solubility of Incidin OxyFoam S?

Not applicable and/or not determined for the mixture

What is Incidin OxyFoam S used for?

Surface Disinfectant. Surface disinfectant. Manual process

What is the melting point of Incidin OxyFoam S?

The melting point is Not applicable and/or not determined for the mixture and the boiling point is 100 ยฐC.