Product Name
Incidin OxyFoam S
Product Code
116307E

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Surface disinfectant. Manual process

Uses advised against

Reserved for industrial and professional use.

Manufacturers & Suppliers

E

Ecolab Ltd.

manufacturer

PO Box 11; Winnington Avenue, Northwich, Cheshire, United Kingdom CW8 4DX

Emergency Contacts

Food & Beverage, Institutional, Agriculture, Textile Hygiene: Northwich

+44 (0)1606 74488

Healthcare Leeds

+44 (0)113 232 2480

Healthcare Swansea

+44 (0)1235 239670

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Hydrogen peroxide EC: 231-765-0 7722-84-1 1 - 2.5% Yes
Glycolic acid EC: 201-180-5 79-14-1 1 - 2.5% Yes

Notes

For the full text of the H-Statements mentioned in this Section, see Section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Get medical attention if symptoms occur.

Skin contact

Rinse with plenty of water.

Eye contact

Rinse with plenty of water.

Ingestion

Rinse mouth. Get medical attention if symptoms occur.

Medical Treatment

No specific measures identified.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Unsuitable media

None known.

Specific hazards

Not flammable or combustible.

Firefighter Protection

Use personal protective equipment.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Stop leak if safe to do so. Contain spillage, and then collect with non-combustible absorbent material, (e.g. sand, earth, diatomaceous earth, vermiculite) and place in container for disposal according to local / national regulations (see section 13). Flush away traces with water. For large spills, dike spilled material or otherwise contain material to ensure runoff does not reach a waterway.

Large spill

For large spills, dike spilled material or otherwise contain material to ensure runoff does not reach a waterway.

Environmental

No special environmental precautions required.

Cleanup methods

collect with non-combustible absorbent material, (e.g. sand, earth, diatomaceous earth, vermiculite) and place in container for disposal according to local / national regulations (see section 13). Flush away traces with water.

Materials: non-combustible absorbent material, (e.g. sand, earth, diatomaceous earth, vermiculite)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Do not mix with bleach or other chlorinated products – will cause chlorine gas.

Storage

Keep out of reach of children. Keep container tightly closed. Store in suitable labeled containers.

Hygiene

Wash hands before breaks and immediately after handling the product.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Good general ventilation should be sufficient to control worker exposure to airborne contaminants.

Hands

No special protective equipment required.

Eyes

No special protective equipment required.

Respiratory

None required if airborne concentrations are maintained below the exposure limit listed in Exposure Limit Information. Use certified respiratory protection equipment meeting EU requirements(89/656/EEC, 89/686/EEC), or equivalent, when respiratory risks cannot be avoided or sufficiently limited by technical means of collective protection or by measures, methods or procedures of work organization.

Skin/Body

No special protective equipment required.

Environmental

Consider the provision of containment around storage vessels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Freezing Point
Not applicable and/or not determined for the mixture
Crystallisation Point
---
Solubility In Fat
---
Solubility In Water
soluble
Melting Point
Not applicable and/or not determined for the mixture
Colour
clear, colourless
Flash Point
Not applicable., Does not sustain combustion.
Solubility
Not applicable and/or not determined for the mixture
Boiling Point
100 °C
Relative Density
1.01 - 1.016
Lower Explosive Limit
Not applicable and/or not determined for the mixture
Dynamic Viscosity
---
Explosive Limits
---
Appearance
liquid
Properties Status
---
Physical State Data
liquid
Evaporation Rate
Not applicable and/or not determined for the mixture
Vapor Pressure
Not applicable and/or not determined for the mixture
Molecular Weight
---
Density
---
Solidification Point
---
Partition Coefficient
Not applicable and/or not determined for the mixture
Auto Ignition Temperature
Not applicable and/or not determined for the mixture
Cloud Point
---
Ph
2.01 - 2.11, 100 %
Flammability
Not applicable and/or not determined for the mixture
Decomposition Temperature
Not applicable and/or not determined for the mixture
Softening Point
---
Upper Explosive Limit
Not applicable and/or not determined for the mixture
Voc Content
---
Bulk Density
---
Vapor Density
---
Odor Threshold
Not applicable and/or not determined for the mixture
Odor
characteristic
Metal Corrosion
---
Physical State
liquid
Relative Evaporation Rate
---
Colour Intensity
---
Kinematic Viscosity
Not applicable and/or not determined for the mixture
Form
---
State Under Standard Conditions
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

No dangerous reaction known under conditions of normal use.

Hazardous reactions

Do not mix with bleach or other chlorinated products – will cause chlorine gas.

Avoid

None known.

Incompatible

None known.

Decomposition

Decomposition products may include the following materials: Carbon oxides, nitrogen oxides (NOx), Sulphur oxides, Oxides of phosphorus

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Diluted product can be flushed to sanitary sewer.

Disposal

Dispose of in accordance with the European Directives on waste and hazardous waste.

Waste Codes

Not specified Inorganic wastes containing dangerous substances. EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
Not dangerous goods
Shipping Name
Not dangerous goods
Transport Class
Not dangerous goods
Packing Group
Not dangerous goods
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Contains: Disinfectants. Detergents composition: < 5% Oxygen-based bleaching agents, < 5% Anionic surfactants.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Incidin OxyFoam S?

The signal word is no signal word.

What is the physical form of Incidin OxyFoam S?

Incidin OxyFoam S is a liquid appearing as liquid with clear, colourless color. It has characteristic odor.

What is the solubility of Incidin OxyFoam S?

Not applicable and/or not determined for the mixture

What is Incidin OxyFoam S used for?

Surface disinfectant. Manual process

What is the melting point of Incidin OxyFoam S?

The melting point is Not applicable and/or not determined for the mixture and the boiling point is 100 °C.