Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Acrylamide/Bis Solution 37,5:1
Product Code
10688

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Laboratory chemicals

Uses advised against

No further relevant information available.

Manufacturers & Suppliers

S

SERVA Electrophoresis GmbH

manufacturer

Carl-Benz-Str. 7 D-69115 Heidelberg

+49 6221 13840-0

Emergency Contacts

Poison Information Center Mainz

+49 (0) 6131 19240

DE, EN

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Muta. Cat. 1B H340
Carc. Cat. 1B H350
Repr. Cat. 2 H361
STOT RE Cat. 1 H372
Acute Tox. Cat. 4 H302
Skin Irrit. Cat. 2 H315
Eye Irrit. Cat. 2 H319
Skin Sens. Cat. 1 H317

GHS Pictograms

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

Hazard Statements

H302 Harmful if swallowed.
H315 Causes skin irritation.
H317 May cause an allergic skin reaction.
H319 Causes serious eye irritation.
H340 May cause genetic defects.
H350 May cause cancer.
H361 Suspected of damaging fertility.
H372 Causes damage to organs through prolonged or repeated exposure.

Precautionary Statements

P201 Obtain special instructions before use.
P264 Wash thoroughly after handling.
P280 Wear protective gloves/protective clothing/eye protection/face protection.
P301 + P312 IF SWALLOWED: Call a POISON CENTER/doctor if you feel unwell.
P302 + P352 IF ON SKIN: Wash with plenty of soap and water.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mixture of the substances listed below with harmless additions.

Chemical Name CAS Number Concentration Hazardous
acrylamide EC: 201-173-7 79-06-1 15 - 30% Yes
N,N'-methylenediacrylamide EC: 203-750-9 110-26-9 1 - 3% Yes

For the wording of the listed hazard phrases refer to section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

In case of unconsciousness place patient stably in side position for transportation. Supply fresh air and to be sure call for a doctor.

Skin contact

Immediate wash with copious amounts of water and soap; rinse thoroughly; seek medical advice.

Eye contact

Rinse opened eye for several minutes under running water. Remove present contact lenses, if easy to do, and continue rinsing. Consult ophthalmologist immediately.

Ingestion

Wash out mouth instantly. Drink copious amounts of water and provide fresh air. Call for doctor immediately.

Immediate Medical Attention

Consult ophthalmologist immediately. Call for doctor immediately.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No further data; see item 7.

Hands

Neoprene gloves PVC gloves Protective gloves. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation PVC (0.5 mm) Butyl (0.5 mm) max. 8 h The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed. For the permanent contact of a maximum of 15 minutes gloves made of the following materials are suitable: PVC gloves Neoprene gloves

Eyes

Tightly sealed goggles.

Respiratory

Short term filter device: Filter A/P3

Skin/Body

Protective work clothing.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Dynamic Viscosity
Not determined.
Upper Explosive Limit
Not determined.
Ph
6-8
Solubility
Fully miscible in Water
Explosive Limits
---
Appearance
Solution Colourless
Metal Corrosion
---
Cloud Point
---
Solubility In Water
Fully miscible
Boiling Point
undetermined
Solubility In Fat
---
Density
1.04 g/cm³
Physical State Data
liquid
State Under Standard Conditions
---
Vapor Pressure
Not determined.
Partition Coefficient
Not determined.
Lower Explosive Limit
Not determined.
Auto Ignition Temperature
Product is not selfigniting.
Evaporation Rate
Not determined.
Form
Solution
Colour
Colourless
Flammability
Not applicable.
Crystallisation Point
---
Vapor Density
Not determined.
Solidification Point
---
Colour Intensity
---
Kinematic Viscosity
Not determined.
Odor
Characteristic
Voc Content
---
Odor Threshold
Not determined.
Physical State
Solution
Softening Point
---
Bulk Density
---
Flash Point
Not applicable
Freezing Point
undetermined
Melting Point
undetermined
Relative Evaporation Rate
---
Molecular Weight
---
Decomposition Temperature
Not determined.
Properties Status
---
Relative Density
Not determined.
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN3426
Shipping Name
ACRYLAMIDE SOLUTION
Transport Class
6.1 Toxic substances.
Packing Group
III
ADR

Warning: Toxic substances.

IMDG

Warning: Toxic substances.

IATA

Warning: Toxic substances.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Acrylamide/Bis Solution 37,5:1?

The signal word is danger.

What is the physical form of Acrylamide/Bis Solution 37,5:1?

Acrylamide/Bis Solution 37,5:1 is a solution appearing as solution colourless with colourless color. It has characteristic odor.

What is the solubility of Acrylamide/Bis Solution 37,5:1?

Fully miscible in Water

What is Acrylamide/Bis Solution 37,5:1 used for?

Laboratory chemicals

What are the hazard statements for Acrylamide/Bis Solution 37,5:1?

This substance has 8 hazard statements:

  • H302: Harmful if swallowed.
  • H315: Causes skin irritation.
  • H317: May cause an allergic skin reaction.
  • H319: Causes serious eye irritation.
  • H340: May cause genetic defects.
  • H350: May cause cancer.
  • H361: Suspected of damaging fertility.
  • H372: Causes damage to organs through prolonged or repeated exposure.

What is the melting point of Acrylamide/Bis Solution 37,5:1?