Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Acrylamide : Bis-Acrylamide 29:1
- Product Code
- BP1408-1
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- K3S8-M3G9-8X04-54YR
Identified Uses
Laboratory chemicals.
Uses advised against
No Information available
Manufacturers & Suppliers
Fisher Scientific UK
distributor
Bishop Meadow Road, Loughborough, Leicestershire LE11 5RG, United Kingdom
Thermo Fisher Scientific
distributor
Janssen Pharmaceuticalaan 3a, 2440 Geel, Belgium
Emergency Contacts
Emergency Contact
001-800-227-6701
Emergency Contact
+32 14 57 52 11
Emergency Contact
001-201-796-7100
Emergency Contact
+32 14 57 52 99
CHEMTREC
001-800-424-9300
CHEMTREC
001-703-527-3887
National Poisons Information Centre (NPIC)
01 809 2166
8am-10pm, 7 days a week
Emergency Contact
+356 2395 2000
Emergency Contact
+357 2240 5611
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
GHS08
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air. If not breathing, give artificial respiration. Do not use mouth-to-mouth method if victim ingested or inhaled the substance; give artificial respiration with the aid of a pocket mask equipped with a one-way valve or other proper respiratory medical device. Immediate medical attention is required.
Symptoms: trouble breathing, dizziness, lightheadedness, chest pain
Wash off immediately with plenty of water for at least 15 minutes. Immediate medical attention is required.
Symptoms: allergic skin reaction, rash, itching, swelling, tingling of the hands and feet, muscle pain, flushing
In the case of contact with eyes, rinse immediately with plenty of water and seek medical advice.
Do NOT induce vomiting. Call a physician or poison control center immediately.
Immediate Medical Attention
Immediate medical attention is required.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray, carbon dioxide (CO2), dry chemical, alcohol-resistant foam.
No information available.
Thermal decomposition can lead to release of irritating gases and vapors.
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.
Firefighter Protection
Wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Ensure adequate ventilation. Use personal protective equipment as required. Keep people away from and upwind of spill/leak. Evacuate personnel to safe areas.
Should not be released into the environment.
Soak up with inert absorbent material.
Materials: inert absorbent material
Related Products
Similar products with comparable safety profiles
30% Acrylamide/Bis Solution, 29:1
---
Acrylamide/Bis Solution 37,5:1
---
Acrylamide / N,N'-Methylenebisacrylamide 37.5:1, 40% mix solution in water
UFI: 35S8-435P-JX0M-UGJT
Acrylamide
CAS: 79-06-1
Acrylamide
CAS: 79-06-1
Acrylamide
CAS: 79-06-1
Acrylamide
CAS: 79-06-1
Acrylamide (40%) Solutions
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Wear personal protective equipment/face protection. Do not get in eyes, on skin, or on clothing. Use only under a chemical fume hood. Do not breathe mist/vapors/spray. Do not ingest. If swallowed then seek immediate medical assistance.
Keep in a dry place. Keep container tightly closed. Protect from direct sunlight. Store under an inert atmosphere. To maintain product quality: Keep refrigerated.
Handle in accordance with good industrial hygiene and safety practice. Keep away from food, drink and animal feeding stuffs. Do not eat, drink or smoke when using this product. Remove and wash contaminated clothing and gloves, including the inside, before re-use. Wash hands before breaks and after work.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure adequate ventilation, especially in confined areas. Ensure that eyewash stations and safety showers are close to the workstation location. Wherever possible, engineering control measures such as the isolation or enclosure of the process, the introduction of process or equipment changes to minimise release or contact, and the use of properly designed ventilation systems, should be adopted to control hazardous materials at source
Protective gloves. Glove material: Nitrile rubber, Neoprene, Natural rubber, PVC. Breakthrough time: See manufacturers recommendations. EU standard: EN 374. (minimum requirement)
Goggles (European standard - EN 166)
When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. To protect the wearer, respiratory protective equipment must be the correct fit and be used and maintained properly. Large scale/emergency use: Use a NIOSH/MSHA or European Standard EN 136 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced Recommended Filter type: Organic gases and vapours filter Type A Brown conforming to EN14387. Small scale/Laboratory use: Use a NIOSH/MSHA or European Standard EN 149:2001 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended half mask:- Valve filtering: EN405; or; Half mask: EN140; plus filter, EN 141 When RPE is used a face piece Fit Test should be conducted
Long sleeved clothing. Inspect gloves before use. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. (Refer to manufacturer/supplier for information) Ensure gloves are suitable for the task: Chemical compatability, Dexterity, Operational conditions, User susceptibility, e.g. sensitisation effects, also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion. Remove gloves with care avoiding skin contamination.
Prevent product from entering drains.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Air sensitive. Light sensitive.
None known, based on information available
None under normal processing. Hazardous Polymerization: No information available.
Exposure to air. Exposure to light. Incompatible products.
Strong oxidizing agents.
Nitrogen oxides (NOx). Carbon monoxide (CO). Carbon dioxide (CO₂). Ammonia.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1. Toxicity
12.1. Toxicity
12.2. Persistence and degradability
12.3. Bioaccumulative potential
12.3. Bioaccumulative potential
12.3. Bioaccumulative potential
12.4. Mobility in soil
12.5. Results of PBT and vPvB assessment
12.6. Endocrine disrupting properties
12.7. Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Dispose of in accordance with the European Directives on waste and hazardous waste.
Dispose of in accordance with local regulations.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Safety, health and environmental regulations/legislation specific for the substance or mixture.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Acrylamide : Bis-Acrylamide 29:1?
The signal word is danger.
What is the physical form of Acrylamide : Bis-Acrylamide 29:1?
Acrylamide : Bis-Acrylamide 29:1 is a liquid appearing as clear . It has no information available odor.
What is the solubility of Acrylamide : Bis-Acrylamide 29:1?
No information available
What is Acrylamide : Bis-Acrylamide 29:1 used for?
Laboratory chemicals.
What are the hazard statements for Acrylamide : Bis-Acrylamide 29:1?
This substance has 8 hazard statements:
- H302: Harmful if swallowed
- H315: Causes skin irritation
- H317: May cause an allergic skin reaction
- H319: Causes serious eye irritation
- H340: May cause genetic defects
- H350: May cause cancer
- H361f: Suspected of damaging fertility
- H372: Causes damage to organs through prolonged or repeated exposure
What is the melting point of Acrylamide : Bis-Acrylamide 29:1?