NextSDS Logo
Safety Data Sheet EN

Acrylamide

CAS 79-06-1
EC 201-173-7

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Acrylamide
Product Code
10674, 10675, 10678
Synonyms
2-Propenamide

Regulatory Identifiers

CAS Number
79-06-1 Check regulations →
EC Number
201-173-7 Check regulations →
REACH No.
01-2119463260-48

Identified Uses

Sector of Use: SU24 Scientific research and development; Product category: PC19 Intermediate, PC21 Laboratory chemicals; Process category: PROC15 Use as laboratory reagent, PROC 0: Other: Monomer for polymerisation; Environmental release category: ERC 0: Other: Laboratory Use; Application of the substance / the mixture: Laboratory chemicals

Manufacturers & Suppliers

S

SERVA Electrophoresis GmbH

manufacturer

Carl-Benz-Str. 7, D-69115 Heidelberg

+49/6221/13840-0

Emergency Contacts

Poison Information Center Mainz

+49 (0) 6131 19240

DE, EN

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Acute Tox. Cat. 3 H301
Muta. Cat. 1B H340
Carc. Cat. 1B H350
Repr. Cat. 2 H361f
STOT RE Cat. 1 H372
Acute Tox. Cat. 4 H312
Acute Tox. Cat. 4 H332
Skin Irrit. Cat. 2 H315
Eye Irrit. Cat. 2 H319
Skin Sens. Cat. 1 H317

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H301 Toxic if swallowed.
H312 + H332 Harmful in contact with skin or if inhaled.
H315 Causes skin irritation.
H317 May cause an allergic skin reaction.
H319 Causes serious eye irritation.
H340 May cause genetic defects.
H350 May cause cancer.
H361f Suspected of damaging fertility.
H372 Causes damage to organs through prolonged or repeated exposure.

Precautionary Statements

P201 Obtain special instructions before use.
P280 Wear protective gloves/protective clothing/eye protection/face protection/hearing protection.
P301 + P310 IF SWALLOWED: Immediately call a POISON CENTER/ doctor.
P302 + P352 IF ON SKIN: Wash with plenty of water.
P304 + P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
acrylamide EC: 201-173-7 79-06-1 --- No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air and to be sure call for a doctor. In case of irregular breathing or respiratory arrest provide artificial respiration.

Skin contact

Immediately wash with water and soap and rinse thoroughly. Consult doctor if you feel unwell.

Eye contact

Rinse opened eye for several minutes under running water. Remove present contact lenses, if easy to do, and continue rinsing. Consult ophthalmologist In case of complaints.

Ingestion

Wash out mouth. Call a doctor immediately. Do not induce vomiting!

Immediate Medical Attention

Call a doctor immediately. Consult doctor if you feel unwell. Consult ophthalmologist In case of complaints.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO₂, extinguishing powder or water spray. Fight larger fires with water spray or alcohol resistant foam.

Specific hazards

In case of fire or strong heating formation of acrid smoke and fumes.

Firefighter Protection

Wear self-contained respiratory protective device.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Do not allow to enter sewers/ surface or ground water.

Cleanup methods

Pick up mechanically.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Residues sublimate easily. Do not inhale vapours. Skin absorbable. Avoid contact with eyes and skin. Open and handle receptacle with care. Keep respiratory protective device available.

Storage

Store at +2 to +8 °C. Store under lock and key and with access restricted to technical experts or their assistants only. Keep receptacle tightly sealed and store in dry conditions. Protect from exposure to the light.

Hygiene

Ensure cleanliness at the workplace.

Fire prevention

Keep ignition sources away - Do not smoke.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No further data; see item 7.

Hands

PVC gloves; Neoprene gloves. Internal tests have shown that some rubber gloves may be subject to permeability to acrylamide. We suggest using neoprene gloves. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Protective gloves. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. Penetration time of glove material: The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed. For the permanent contact of a maximum of 15 minutes gloves made of the following materials are suitable: PVC gloves, Neoprene gloves.

Eyes

Tightly sealed goggles.

Respiratory

Short term filter device: Filter P3. In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use respiratory protective device that is independent of circulating air.

Skin/Body

Protective work clothing.

Environmental

Ecological informations see section 12. Do not exceed PNEC.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Solid.
Physical State Data
solid
State Under Standard Conditions
---
Appearance
---
Colour
White
Colour Intensity
---
Form
Crystalline
Odor
Odourless
Odor Threshold
Not determined.
Ph
5-8
Melting Point
84-85 °C
Boiling Point
polymerizes below boiling point.
Flash Point
not applicable: solid, polymerizes below boiling point.
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
0.009 hPa
Vapor Density
---
Relative Density
Not determined.
Bulk Density
---
Density
1.02 g/cm³
Flammability
no information available
Upper Explosive Limit
Not determined.
Lower Explosive Limit
Not determined.
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
no information available
Solubility
---
Partition Coefficient
Not determined.
Solubility In Water
2040 g/l
Solubility In Fat
---
Molecular Weight
71.1 g/mol
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
Not applicable.
Kinematic Viscosity
Not applicable.
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Reactivity

No further relevant informations available

Hazardous reactions

polymerizes when heated

Avoid

heated

Incompatible

oxidizing agents

Decomposition

In case of fire: See Section 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN2074
Shipping Name
ACRYLAMIDE, SOLID
Transport Class
6.1
Packing Group
III
ADR

Warning: Toxic substances.

IMDG

Warning: Toxic substances. Stowage Category A. Stowage Code SWI Protected from sources of heat. Handling Code H2 Keep as cool as reasonably practicable

IATA

Warning: Toxic substances.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is Acrylamide known by?

Acrylamide is also known as: 2-Propenamide

What is the hazard signal word for Acrylamide?

The signal word is danger.

What is the physical form of Acrylamide?

Acrylamide is a solid. with white color. It has odourless odor.

What is Acrylamide used for?

Sector of Use: SU24 Scientific research and development; Product category: PC19 Intermediate, PC21 Laboratory chemicals; Process category: PROC15 Use as laboratory reagent, PROC 0: Other: Monomer for polymerisation; Environmental release category: ERC 0: Other: Laboratory Use; Application of the substance / the mixture: Laboratory chemicals

What are the hazard statements for Acrylamide?

This substance has 9 hazard statements:

  • H301: Toxic if swallowed.
  • H312 + H332: Harmful in contact with skin or if inhaled.
  • H315: Causes skin irritation.
  • H317: May cause an allergic skin reaction.
  • H319: Causes serious eye irritation.
  • H340: May cause genetic defects.
  • H350: May cause cancer.
  • H361f: Suspected of damaging fertility.
  • H372: Causes damage to organs through prolonged or repeated exposure.

What is the melting point of Acrylamide?

The melting point is 84-85 °C and the boiling point is polymerizes below boiling point..