Product Name
LUBRICANT FOR PIPE THREADING AND METAL FORMING
Product Code
11931, 11531, 16951, 27521, 41585

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Lubricant

Overview

LUBRICANT FOR PIPE THREADING AND METAL FORMING commonly used lubricant.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word (Void)

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

RIDGE TOOL EUROPE N.V.

manufacturer

๐Ÿ“

Interleuvenlaan 50 3001 Heverlee Belgium

๐ŸŒ

BE

๐Ÿ“ž

0032 (0) 16 380 280

๐Ÿ“ 

0032 (0) 16 380 381

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Mixtures

General Composition

A blend of highly refined mineral oils with multifunctional additives.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Nonionic surfactant
EC: 500-195-7
68131-39-5 2.5% โš ๏ธ Hazardous

Additional Information

For the wording of the listed risk phrases refer to section 16.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Supply fresh air; consult doctor in case of complaints.

๐Ÿ–๏ธ Skin Contact

Immediately wash with water and soap and rinse thoroughly.

Symptoms:

skin irritation

๐Ÿ‘๏ธ Eye Contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

๐Ÿฝ๏ธ Ingestion/Swallowing

Do not induce vomiting; call for medical help immediately.

๐Ÿšจ Immediate Medical Attention Required

No further relevant information available.

Medical Treatment

No further relevant information available.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Fluid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Brown
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Fluid
๐Ÿ‘ƒ Odor
Pleasant
๐Ÿ“Š Odor Threshold
Not determined.
๐Ÿงช Ph
Not determined.
๐ŸงŠ Melting Point
Undetermined.
Critical Property
๐Ÿ’จ Boiling Point
> 250
Critical Property
๐Ÿ”ฅ Flash Point
> 100
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not determined.
๐Ÿ’จ Vapor Pressure
Not determined.
๐Ÿ“Š Vapor Density
Not determined.
๐Ÿ“Š Relative Density
Not determined.
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
0.89 g/cm3
Critical Property
๐Ÿ”ฅ Flammability
Not applicable.
๐Ÿ“Š Upper Explosive Limit
Not determined.
๐Ÿ“Š Lower Explosive Limit
Not determined.
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
>250
๐Ÿ“Š Decomposition Temperature
Not determined.
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not determined.
๐Ÿ“Š Solubility In Water
Fully miscible.
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not determined.
๐Ÿ“Š Kinematic Viscosity
30 cSt
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿงค Hand Protection

The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.

๐Ÿ‘๏ธ Eye Protection

Goggles recommended during refilling

๐Ÿ˜ท Respiratory Protection

Not required.

๐Ÿฆบ Skin/Body Protection

Oil resistant protective clothing

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

Void

๐Ÿ“ฆ Proper Shipping Name

Void

โš ๏ธ Transport Hazard Class

Void

๐Ÿ“‹ Packing Group

Void

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for LUBRICANT FOR PIPE THREADING AND METAL FORMING?

The signal word for this substance is "no signal word".

What is the physical form of LUBRICANT FOR PIPE THREADING AND METAL FORMING?

LUBRICANT FOR PIPE THREADING AND METAL FORMING is a fluid with brown color. It has pleasant odor.

What is LUBRICANT FOR PIPE THREADING AND METAL FORMING used for?

Lubricant

What is the melting point of LUBRICANT FOR PIPE THREADING AND METAL FORMING?

The melting point is Undetermined. and the boiling point is > 250.