Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Ascusol PU 92
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
At this time we do not yet have information on identified uses. They will be included in this safety data sheet when available.
Uses advised against
At this moment we have not identified any uses advised against
Manufacturers & Suppliers
Brenntag GmbH
national supplier
Messeallee 11, DE 45131 Essen
+49 (0)201 6496-0
Emergency Contacts
Emergency Contact
+49 (0)201-6496-0
24h/7d
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS08
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Hydrocarbons, C10-C13, n-alkanes, isoalkanes, cyclics, < 2% aromatics EC: 918-481-9 | --- | 30 - 50% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air. If symptoms persist, call a physician. If unconscious, place in recovery position and seek medical advice.
Symptoms: CNS-depression and narcosis.
Wash off immediately with soap and plenty of water. If skin irritation persists, call a physician.
Symptoms: Dries out the skin.
Rinse thoroughly with plenty of water, also under the eyelids. Consult a physician.
If swallowed, DO NOT induce vomiting. Risk of aspiration! Call a physician immediately. If a person vomits when lying on his back, place him in the recovery position.
Symptoms: Risk of aspiration! Risk of serious damage to the lungs (by aspiration). Aspiration may cause pulmonary oedema and pneumonitis.
Immediate Medical Attention
Call a physician immediately if swallowed. Seek medical advice if unconscious after inhalation. Consult a physician for eye contact or if symptoms persist after inhalation/skin contact.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
High volume water jet
Combustible liquid. Vapours may form explosive mixtures with air.
Cool closed containers exposed to fire with water spray.
Firefighter Protection
In the event of fire, wear self-contained breathing apparatus. Wear appropriate body protection (full protective suit).
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protective equipment. Keep away unprotected persons. Provide adequate ventilation. Keep away from heat and sources of ignition. Avoid contact with skin and eyes. Do not breathe gas/fumes/vapour/spray.
Do not flush into surface water or sanitary sewer system. Avoid subsoil penetration.
Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders). Keep in suitable, closed containers for disposal.
Materials: liquid-binding material (sand, diatomite, acid binders, universal binders)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Keep container tightly closed. Provide sufficient air exchange and/or exhaust in work rooms. Do not breathe gas/fumes/vapour/spray. Avoid contact with the skin and the eyes.
Keep tightly closed in a dry and cool place. Keep in a well-ventilated place. Keep away from heat.
Take off all contaminated clothing immediately. Do not breathe gas/fumes/vapour/spray. Avoid contact with the skin and the eyes. Keep away from food, drink and animal feedingstuffs. Smoking, eating and drinking should be prohibited in the application area. Wash hands before breaks and at the end of workday.
Combustible liquid. Possible formation of ignitable mixtures in air if heated above flash point and/or if sprayed (atomised). Take measures to prevent the build up of electrostatic charge. Remove all sources of ignition.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Solvent-resistant gloves The data about break through time/strength of material are standard values! The exact break through time/strength of material has to be obtained from the producer of the protective glove. Protective gloves should be replaced at first signs of wear. As the product is a mixture of several substances, the durability of the glove materials cannot be calculated in advance and has to be tested before use.
Tightly fitting safety goggles
In case of insufficient ventilation, wear suitable respiratory equipment. When aerosol or mist is formed use suitable respiratory protection. Recommended Filter type: Combination filter: A-P2
Solvent resistant protective clothing Flame retardant protective clothing
Do not flush into surface water or sanitary sewer system. Avoid subsoil penetration. If the product contaminates rivers and lakes or drains inform respective authorities. Local authorities should be advised if significant spillages cannot be contained.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The data for this section has not been processed yet.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1. Toxicity
12.2. Persistence and degradability
The individual components are readily biodegradable.
12.3. Bioaccumulative potential
No data available regarding the bioaccumulative potential of the product.
12.4. Mobility in soil
The product is partly soluble in water.
12.5. Results of PBT and vPvB assessment
The substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.
12.6. Other adverse effects
Do not flush into surface water or sanitary sewer system.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1993
- Shipping Name
- FLAMMABLE LIQUID, N.O.S.
- Packing Group
- III
Not applicable.
Not applicable.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Ascusol PU 92?
The signal word is danger.
What is the physical form of Ascusol PU 92?
Ascusol PU 92 is a liquid with colourless color. It has characteristic odor.
What is Ascusol PU 92 used for?
At this time we do not yet have information on identified uses. They will be included in this safety data sheet when available.
What are the hazard statements for Ascusol PU 92?
This substance has 2 hazard statements:
- H226: Flammable liquid and vapour.
- H304: May be fatal if swallowed and enters airways.
What is the melting point of Ascusol PU 92?
The melting point is no data available and the boiling point is ca. 160 - 260 C.