NextSDS Logo
As

Ascusol PU 92

DANGER liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Ascusol PU 92

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
At this time we do not yet have information on identified uses. They will be included in this safety data sheet when available.
Uses Advised Against
At this moment we have not identified any uses advised against

Overview

Ascusol PU 92 commonly used at this time we do not yet have information on identified uses. they will be included in this safety data sheet when available..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Flam. Liq. Category 3 H226
Asp. Tox. Category 1 H304

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS08 GHS Hazard Pictogram: Serious health hazard - Carcinogenic, mutagenic, or toxic to organs

GHS08

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H226: Flammable liquid and vapour.
  • H304: May be fatal if swallowed and enters airways.

Precautionary Statements

  • P280: Wear protective gloves/ protective clothing/ eye protection/ face protection.
  • P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
  • P331: Do NOT induce vomiting.
  • IF SWALLOWED: Immediately call a POISON CENTER/doctor.
  • IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower.
  • Store in a well-ventilated place. Keep cool.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Brenntag GmbH

undefined

๐Ÿ“

Messeallee 11 DE 45131 Essen

๐ŸŒ

DE

๐Ÿ“ 

+49 (0)201 6496-2039

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

+49 (0)201-6496-0

๐ŸŒ

DE

๐Ÿ•’

Available 24h/7d

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Hydrocarbons, C10-C13, n-alkanes, isoalkanes, cyclics, < 2% aromatics
EC: 918-481-9
N/A 30-50% โš ๏ธ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Remove to fresh air. If symptoms persist, call a physician. If unconscious, place in recovery position and seek medical advice.

Symptoms:

CNS-depression and narcosis.

๐Ÿ–๏ธ Skin Contact

Wash off immediately with soap and plenty of water. If skin irritation persists, call a physician.

Symptoms:

Dries out the skin.

๐Ÿ‘๏ธ Eye Contact

Rinse thoroughly with plenty of water, also under the eyelids. Consult a physician.

๐Ÿฝ๏ธ Ingestion/Swallowing

If swallowed, DO NOT induce vomiting. Risk of aspiration! Call a physician immediately. If a person vomits when lying on his back, place him in the recovery position.

Symptoms:

Risk of aspiration! Risk of serious damage to the lungs (by aspiration). Aspiration may cause pulmonary oedema and pneumonitis.

๐Ÿšจ Immediate Medical Attention Required

Call a physician immediately if swallowed. Seek medical advice if unconscious after inhalation. Consult a physician for eye contact or if symptoms persist after inhalation/skin contact.

Medical Treatment

Treat symptomatically.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
colourless
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
liquid
๐Ÿ‘ƒ Odor
characteristic
๐Ÿ“Š Odor Threshold
no data available
๐Ÿงช Ph
Not applicable
๐ŸงŠ Melting Point
no data available
Critical Property
๐Ÿ’จ Boiling Point
ca. 160 - 260 C
Critical Property
๐Ÿ”ฅ Flash Point
59 C
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
no data available
๐Ÿ’จ Vapor Pressure
no data available
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
0,875 g/cm3 (20 C)
Critical Property
๐Ÿ”ฅ Flammability
Flammable.
๐Ÿ“Š Upper Explosive Limit
7,0 %(V)
๐Ÿ“Š Lower Explosive Limit
0,6 %(V)
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
no data available
๐Ÿ“Š Decomposition Temperature
no data available
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
no data available
๐Ÿ“Š Solubility In Water
not respectively poorly mixable
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
no data available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿงค Hand Protection

Solvent-resistant gloves The data about break through time/strength of material are standard values! The exact break through time/strength of material has to be obtained from the producer of the protective glove. Protective gloves should be replaced at first signs of wear. As the product is a mixture of several substances, the durability of the glove materials cannot be calculated in advance and has to be tested before use.

๐Ÿ‘๏ธ Eye Protection

Tightly fitting safety goggles

๐Ÿ˜ท Respiratory Protection

In case of insufficient ventilation, wear suitable respiratory equipment. When aerosol or mist is formed use suitable respiratory protection. Recommended Filter type: Combination filter: A-P2

๐Ÿฆบ Skin/Body Protection

Solvent resistant protective clothing Flame retardant protective clothing

๐ŸŒ Environmental Exposure Controls

Do not flush into surface water or sanitary sewer system. Avoid subsoil penetration. If the product contaminates rivers and lakes or drains inform respective authorities. Local authorities should be advised if significant spillages cannot be contained.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

1993

๐Ÿ“ฆ Proper Shipping Name

FLAMMABLE LIQUID, N.O.S.

๐Ÿ“‹ Packing Group

III

๐Ÿš› ADR Transport Precautions

Not applicable.

๐Ÿšข IMDG Maritime Transport Precautions

Not applicable.

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Ascusol PU 92?

The signal word for this substance is "danger".

What is the physical form of Ascusol PU 92?

Ascusol PU 92 is a liquid with colourless color. It has characteristic odor.

What is Ascusol PU 92 used for?

At this time we do not yet have information on identified uses. They will be included in this safety data sheet when available.

What are the hazard statements for Ascusol PU 92?

This substance has 2 hazard statements: H226: Flammable liquid and vapour. H304: May be fatal if swallowed and enters airways.

What is the melting point of Ascusol PU 92?

The melting point is no data available and the boiling point is ca. 160 - 260 C.