NextSDS Logo
Safety Data Sheet EN

Ascusol PU 92

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Ascusol PU 92

Regulatory Identifiers

CAS Number
N/A

Identified Uses

At this time we do not yet have information on identified uses. They will be included in this safety data sheet when available.

Uses advised against

At this moment we have not identified any uses advised against

Manufacturers & Suppliers

B

Brenntag GmbH

national supplier

Messeallee 11, DE 45131 Essen

+49 (0)201 6496-0

Emergency Contacts

Emergency Contact

+49 (0)201-6496-0

24h/7d

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Asp. Tox. Cat. 1 H304
Flam. Liq. Cat. 3 H226

GHS Pictograms

GHS02 - Flammable

GHS02

GHS08 - Serious health hazard

GHS08

Hazard Statements

H226 Flammable liquid and vapour.
H304 May be fatal if swallowed and enters airways.

Precautionary Statements

P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P280 Wear protective gloves/ protective clothing/ eye protection/ face protection.
P301 + P310 IF SWALLOWED: Immediately call a POISON CENTER/doctor.
P303 + P361 + P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower.
P331 Do NOT induce vomiting.
P403 + P235 Store in a well-ventilated place. Keep cool.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Hydrocarbons, C10-C13, n-alkanes, isoalkanes, cyclics, < 2% aromatics EC: 918-481-9 --- 30 - 50% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove to fresh air. If symptoms persist, call a physician. If unconscious, place in recovery position and seek medical advice.

Symptoms: CNS-depression and narcosis.

Skin contact

Wash off immediately with soap and plenty of water. If skin irritation persists, call a physician.

Symptoms: Dries out the skin.

Eye contact

Rinse thoroughly with plenty of water, also under the eyelids. Consult a physician.

Ingestion

If swallowed, DO NOT induce vomiting. Risk of aspiration! Call a physician immediately. If a person vomits when lying on his back, place him in the recovery position.

Symptoms: Risk of aspiration! Risk of serious damage to the lungs (by aspiration). Aspiration may cause pulmonary oedema and pneumonitis.

Immediate Medical Attention

Call a physician immediately if swallowed. Seek medical advice if unconscious after inhalation. Consult a physician for eye contact or if symptoms persist after inhalation/skin contact.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.

Unsuitable media

High volume water jet

Specific hazards

Combustible liquid. Vapours may form explosive mixtures with air.

Instructions

Cool closed containers exposed to fire with water spray.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus. Wear appropriate body protection (full protective suit).

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protective equipment. Keep away unprotected persons. Provide adequate ventilation. Keep away from heat and sources of ignition. Avoid contact with skin and eyes. Do not breathe gas/fumes/vapour/spray.

Environmental

Do not flush into surface water or sanitary sewer system. Avoid subsoil penetration.

Cleanup methods

Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders). Keep in suitable, closed containers for disposal.

Materials: liquid-binding material (sand, diatomite, acid binders, universal binders)

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Keep container tightly closed. Provide sufficient air exchange and/or exhaust in work rooms. Do not breathe gas/fumes/vapour/spray. Avoid contact with the skin and the eyes.

Storage

Keep tightly closed in a dry and cool place. Keep in a well-ventilated place. Keep away from heat.

Hygiene

Take off all contaminated clothing immediately. Do not breathe gas/fumes/vapour/spray. Avoid contact with the skin and the eyes. Keep away from food, drink and animal feedingstuffs. Smoking, eating and drinking should be prohibited in the application area. Wash hands before breaks and at the end of workday.

Fire prevention

Combustible liquid. Possible formation of ignitable mixtures in air if heated above flash point and/or if sprayed (atomised). Take measures to prevent the build up of electrostatic charge. Remove all sources of ignition.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Solvent-resistant gloves The data about break through time/strength of material are standard values! The exact break through time/strength of material has to be obtained from the producer of the protective glove. Protective gloves should be replaced at first signs of wear. As the product is a mixture of several substances, the durability of the glove materials cannot be calculated in advance and has to be tested before use.

Eyes

Tightly fitting safety goggles

Respiratory

In case of insufficient ventilation, wear suitable respiratory equipment. When aerosol or mist is formed use suitable respiratory protection. Recommended Filter type: Combination filter: A-P2

Skin/Body

Solvent resistant protective clothing Flame retardant protective clothing

Environmental

Do not flush into surface water or sanitary sewer system. Avoid subsoil penetration. If the product contaminates rivers and lakes or drains inform respective authorities. Local authorities should be advised if significant spillages cannot be contained.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
colourless
Colour Intensity
---
Form
liquid
Odor
characteristic
Odor Threshold
no data available
Ph
Not applicable
Melting Point
no data available
Boiling Point
ca. 160 - 260 C
Flash Point
59 C
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
no data available
Vapor Pressure
no data available
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
0,875 g/cm3 (20 C)
Flammability
Flammable.
Upper Explosive Limit
7,0 %(V)
Lower Explosive Limit
0,6 %(V)
Explosive Limits
---
Auto Ignition Temperature
no data available
Decomposition Temperature
no data available
Solubility
---
Partition Coefficient
no data available
Solubility In Water
not respectively poorly mixable
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
no data available
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1. Toxicity

Component: Hydrocarbons, C10-C13, n-alkanes, isoalkanes, cyclics, < 2% aromatics Acute toxicity Fish LL0 : 1000 mg/l (Oncorhynchus mykiss (rainbow trout); 96 h) (Toxicity to fish) Toxicity to daphnia and other aquatic invertebrates EL0 : 1000 mg/l (Daphnia magna (Water flea); 48 h) (Toxicity to daphnia) algae EL0 : 1000 mg/l (Pseudokirchneriella subcapitata (green algae); 72 h) (Toxicity to algae)

12.2. Persistence and degradability

Data for the product Persistence and degradability Biodegradability Result : The individual components are readily biodegradable.

The individual components are readily biodegradable.

12.3. Bioaccumulative potential

Data for the product | Bioaccumulation | Result : no data available

No data available regarding the bioaccumulative potential of the product.

12.4. Mobility in soil

Data for the product Mobility Result : The product is partly soluble in water.

The product is partly soluble in water.

12.5. Results of PBT and vPvB assessment

Result : This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.

The substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.

12.6. Other adverse effects

Additional ecological information Result : Do not flush into surface water or sanitary sewer system.

Do not flush into surface water or sanitary sewer system.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1993
Shipping Name
FLAMMABLE LIQUID, N.O.S.
Packing Group
III
ADR

Not applicable.

IMDG

Not applicable.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Ascusol PU 92?

The signal word is danger.

What is the physical form of Ascusol PU 92?

Ascusol PU 92 is a liquid with colourless color. It has characteristic odor.

What is Ascusol PU 92 used for?

At this time we do not yet have information on identified uses. They will be included in this safety data sheet when available.

What are the hazard statements for Ascusol PU 92?

This substance has 2 hazard statements:

  • H226: Flammable liquid and vapour.
  • H304: May be fatal if swallowed and enters airways.

What is the melting point of Ascusol PU 92?

The melting point is no data available and the boiling point is ca. 160 - 260 C.