Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- MOISTURE GUARD Clear Spray
- Product Form
- Mixture
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- 7170-D091-300X-NCSG
Identified Uses
Corrosion inhibitors
Uses advised against
Acetone is listed as a reportable explosives precursor in Annex II of EU regulation 2019/1148
Manufacturers & Suppliers
ROCOL a division of ITW Ltd
manufacturer
Rocol House Wakefield Rd, Swillington, LS26 8BS Leeds – West Yorkshire, United Kingdom
+44 (0)113 232 2600
http://www.rocol.com
Emergency Contacts
Emergency Contact
+44 (0)113 232 2600
National Poisons Information Service (Birmingham Centre) City Hospital
0344 892 0111
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| HYDROCARBON AEROSOL PROPELLANT (<0.1% 1,3-BUTADIENE) EC: 270-704-2 | 68476-85-7 | 50 - 70% | Yes |
| HEPTANE & ISOMERS EC: 927-510-4 | 64742-49-0 | 15 - 30% | Yes |
| ACETONE EC: 200-662-2 | 67-64-1 | 5 - 10% | Yes |
Full text of H- and EUH-statements: see section 16
Notes
Product subject to CLP Article 1.1.3.7. The disclosure rules of the components is modified in this case.
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove person to fresh air and keep comfortable for breathing. Call a POISON CENTER/doctor if you feel unwell.
Symptoms: May cause drowsiness or dizziness.
Rinse immediately with plenty of water. Obtain medical attention if pain, blinking or redness persists.
Rinse mouth. Do NOT induce vomiting. Obtain emergency medical attention.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Foam. Dry powder. Carbon dioxide. Water spray. Sand.
Do not use a heavy water stream.
Use water spray or fog for cooling exposed containers. Exercise caution when fighting any chemical fire.
Firefighter Protection
Do not enter fire area without proper protective equipment, including respiratory protection.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Evacuate unnecessary personnel. Ventilate area.
Prevent entry to sewers and public waters. Avoid release to the environment.
Soak up spills with inert solids, such as clay or diatomaceous earth as soon as possible. Collect spillage.
Materials: inert solids, such as clay or diatomaceous earth
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work. Provide good ventilation in process area to prevent formation of vapour. Avoid breathing dust/fume/gas/mist/vapours/spray. Use only outdoors or in a well-ventilated area.
Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Keep container tightly closed.
Wash hands, forearms and face thoroughly after handling.
Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Wear protective gloves. Nitrile rubber gloves
Chemical goggles or safety glasses
In case of inadequate ventilation wear respiratory protection. Wear a respirator conforming to EN140 with Type A filter or better
Wear suitable protective clothing
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Not established.
Extremely flammable aerosol.
Not established.
Direct sunlight. Extremely high or low temperatures.
Strong acids. Strong bases.
fume. Carbon monoxide. Carbon dioxide.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Dispose in a safe manner in accordance with local/national regulations. Dispose of contents/container to hazardous or special waste collection point, in accordance with local, regional, national and/or international regulation.
Dispose in a safe manner in accordance with local/national regulations. Dispose of contents/container to hazardous or special waste collection point, in accordance with local, regional, national and/or international regulation.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1950
- Shipping Name
- AEROSOLS
- Transport Class
- 2.1
- Packing Group
- Not applicable
Special provisions for carriage - Packages (ADR) : V14; Special provisions for carriage - Loading, unloading and handling (ADR) : CV9, CV12; Special provisions for carriage - Operation (ADR) : S2
63, 190, 277, 327, 344, 381, 959
ERG code (IATA) : 10L
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for MOISTURE GUARD Clear Spray?
The signal word is danger.
What is the physical form of MOISTURE GUARD Clear Spray?
MOISTURE GUARD Clear Spray is a liquid with brown. color. It has characteristic odour. odor.
What is the solubility of MOISTURE GUARD Clear Spray?
insoluble in water.
What is MOISTURE GUARD Clear Spray used for?
Corrosion inhibitors
What are the hazard statements for MOISTURE GUARD Clear Spray?
This substance has 5 hazard statements:
- H222: Extremely flammable aerosol.
- H229: Pressurised container: May burst if heated.
- H315: Causes skin irritation.
- H336: May cause drowsiness or dizziness.
- H412: Harmful to aquatic life with long lasting effects.
What is the melting point of MOISTURE GUARD Clear Spray?
The melting point is Not available and the boiling point is < 0 °C.