NextSDS Logo
Safety Data Sheet EN

MOISTURE GUARD Clear Spray

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
MOISTURE GUARD Clear Spray
Product Form
Mixture

Regulatory Identifiers

CAS Number
N/A
UFI Code
7170-D091-300X-NCSG

Identified Uses

Corrosion inhibitors

Uses advised against

Acetone is listed as a reportable explosives precursor in Annex II of EU regulation 2019/1148

Manufacturers & Suppliers

ROCOL a division of ITW Ltd logo

ROCOL a division of ITW Ltd

manufacturer

Rocol House Wakefield Rd, Swillington, LS26 8BS Leeds – West Yorkshire, United Kingdom

+44 (0)113 232 2600

http://www.rocol.com

Emergency Contacts

Emergency Contact

+44 (0)113 232 2600

National Poisons Information Service (Birmingham Centre) City Hospital

0344 892 0111

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Aerosol Cat. 1 H222
Skin Irrit. Cat. 2 H315
STOT SE Cat. 3 H336
Aquatic Chronic Cat. 3 H412

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

Hazard Statements

H222 Extremely flammable aerosol.
H229 Pressurised container: May burst if heated.
H315 Causes skin irritation.
H336 May cause drowsiness or dizziness.
H412 Harmful to aquatic life with long lasting effects.

Precautionary Statements

P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P211 Do not spray on an open flame or other ignition source.
P251 Do not pierce or burn, even after use.
P271 Use only outdoors or in a well-ventilated area.
P280 Wear protective gloves/protective clothing/eye protection/face protection/hearing protection.
P302 + P352 IF ON SKIN: Wash with plenty of water.
P410 + P412 Protect from sunlight. Do not expose to temperatures exceeding 50 °C/122 °F.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
HYDROCARBON AEROSOL PROPELLANT (<0.1% 1,3-BUTADIENE) EC: 270-704-2 68476-85-7 50 - 70% Yes
HEPTANE & ISOMERS EC: 927-510-4 64742-49-0 15 - 30% Yes
ACETONE EC: 200-662-2 67-64-1 5 - 10% Yes

Full text of H- and EUH-statements: see section 16

Notes

Product subject to CLP Article 1.1.3.7. The disclosure rules of the components is modified in this case.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove person to fresh air and keep comfortable for breathing. Call a POISON CENTER/doctor if you feel unwell.

Symptoms: May cause drowsiness or dizziness.

Eye contact

Rinse immediately with plenty of water. Obtain medical attention if pain, blinking or redness persists.

Ingestion

Rinse mouth. Do NOT induce vomiting. Obtain emergency medical attention.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Foam. Dry powder. Carbon dioxide. Water spray. Sand.

Unsuitable media

Do not use a heavy water stream.

Instructions

Use water spray or fog for cooling exposed containers. Exercise caution when fighting any chemical fire.

Firefighter Protection

Do not enter fire area without proper protective equipment, including respiratory protection.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Evacuate unnecessary personnel. Ventilate area.

Environmental

Prevent entry to sewers and public waters. Avoid release to the environment.

Cleanup methods

Soak up spills with inert solids, such as clay or diatomaceous earth as soon as possible. Collect spillage.

Materials: inert solids, such as clay or diatomaceous earth

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work. Provide good ventilation in process area to prevent formation of vapour. Avoid breathing dust/fume/gas/mist/vapours/spray. Use only outdoors or in a well-ventilated area.

Storage

Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Keep container tightly closed.

Hygiene

Wash hands, forearms and face thoroughly after handling.

Fire prevention

Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Wear protective gloves. Nitrile rubber gloves

Eyes

Chemical goggles or safety glasses

Respiratory

In case of inadequate ventilation wear respiratory protection. Wear a respirator conforming to EN140 with Type A filter or better

Skin/Body

Wear suitable protective clothing

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Solidification Point
---
Boiling Point
< 0 °C
Form
---
Vapor Density
---
Dynamic Viscosity
---
Partition Coefficient
Not available
Freezing Point
Not available
Physical State Data
liquid
Melting Point
Not available
Explosive Limits
---
Odor Threshold
Not available
Appearance
---
Solubility In Water
insoluble
Odor
Characteristic odour.
Flammability
Non flammable.
Voc Content
563 g/l
Kinematic Viscosity
Not available
Colour
brown.
Solubility In Fat
---
Metal Corrosion
---
Cloud Point
---
Decomposition Temperature
Not available
Evaporation Rate
---
Flash Point
< 100 °C
Crystallisation Point
---
Solubility
insoluble in water.
Softening Point
---
Colour Intensity
---
Density
Not available
Properties Status
---
Physical State
Liquid
Bulk Density
---
Relative Density
≈ 0.6
Auto Ignition Temperature
> 200 °C
State Under Standard Conditions
---
Molecular Weight
---
Upper Explosive Limit
Not available
Ph
Not available
Vapor Pressure
Not available
Lower Explosive Limit
Not available
Relative Evaporation Rate
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Not established.

Reactivity

Extremely flammable aerosol.

Hazardous reactions

Not established.

Avoid

Direct sunlight. Extremely high or low temperatures.

Incompatible

Strong acids. Strong bases.

Decomposition

fume. Carbon monoxide. Carbon dioxide.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Dispose in a safe manner in accordance with local/national regulations. Dispose of contents/container to hazardous or special waste collection point, in accordance with local, regional, national and/or international regulation.

Disposal

Dispose in a safe manner in accordance with local/national regulations. Dispose of contents/container to hazardous or special waste collection point, in accordance with local, regional, national and/or international regulation.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1950
Shipping Name
AEROSOLS
Transport Class
2.1
Packing Group
Not applicable
ADR

Special provisions for carriage - Packages (ADR) : V14; Special provisions for carriage - Loading, unloading and handling (ADR) : CV9, CV12; Special provisions for carriage - Operation (ADR) : S2

IMDG

63, 190, 277, 327, 344, 381, 959

IATA

ERG code (IATA) : 10L

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for MOISTURE GUARD Clear Spray?

The signal word is danger.

What is the physical form of MOISTURE GUARD Clear Spray?

MOISTURE GUARD Clear Spray is a liquid with brown. color. It has characteristic odour. odor.

What is the solubility of MOISTURE GUARD Clear Spray?

insoluble in water.

What is MOISTURE GUARD Clear Spray used for?

Corrosion inhibitors

What are the hazard statements for MOISTURE GUARD Clear Spray?

This substance has 5 hazard statements:

  • H222: Extremely flammable aerosol.
  • H229: Pressurised container: May burst if heated.
  • H315: Causes skin irritation.
  • H336: May cause drowsiness or dizziness.
  • H412: Harmful to aquatic life with long lasting effects.

What is the melting point of MOISTURE GUARD Clear Spray?

The melting point is Not available and the boiling point is < 0 °C.