NextSDS Logo
EV

EVAPO-RUST

NO SIGNAL WORD Liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
EVAPO-RUST
Product Code
BDS002699BU

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Rust remover

Overview

EVAPO-RUST commonly used rust remover.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

CRC Industries Europe B.V. company logo - Safety Data Sheet supplier organization

CRC Industries Europe B.V.

undefined

๐Ÿ“

Touwslagerstraat 1 9240 Zele Belgium

๐ŸŒ

BE

๐Ÿ“ 

+32(0)52/45.00.34

๐ŸŒ www.crcind.com

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

+32(0)52/45.60.11

๐ŸŒ

BE

๐Ÿ•’

Office hours: 9-17h CET

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
2,2',2"-nitrilotriethanol
EC: 203-049-8
102-71-6 1-5% โœ“ Non-hazardous
Salt of an aliphatic acid N/A 5% โš ๏ธ Hazardous
Aliphatic carboxylic acid N/A 3% โš ๏ธ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Remove person to fresh air and keep comfortable for breathing. If signs/symptoms develop, get medical attention.

๐Ÿ–๏ธ Skin Contact

Wash skin with plenty of water. Seek medical attention if irritation develops.

๐Ÿ‘๏ธ Eye Contact

Rinse eyes with water as a precaution. Seek medical attention if irritation develops.

๐Ÿฝ๏ธ Ingestion/Swallowing

Call a poison center or a doctor if you feel unwell.

๐Ÿšจ Immediate Medical Attention Required

Provide general supportive measures and treat symptomatically. Keep victim under observation. Symptoms may be delayed.

Medical Treatment

Provide general supportive measures and treat symptomatically.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
colourless to yellow.
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Neutral.
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
5,5
๐ŸงŠ Melting Point
Not applicable
Critical Property
๐Ÿ’จ Boiling Point
> 100
Critical Property
๐Ÿ”ฅ Flash Point
Not applicable
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
Not available
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
1,05 at 20
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
1,05 g/cm3 at 20
Critical Property
๐Ÿ”ฅ Flammability
Non flammable.
๐Ÿ“Š Upper Explosive Limit
Not applicable
๐Ÿ“Š Lower Explosive Limit
Not applicable
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
> 200
๐Ÿ“Š Decomposition Temperature
Not available
๐Ÿ’ง Solubility
soluble in water.
๐Ÿ“Š Partition Coefficient
Not applicable
๐Ÿ“Š Solubility In Water
soluble in water.
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Good general ventilation should be used. Ventilation rates should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits. If exposure limits have not been established, maintain airborne levels to an acceptable level.

๐Ÿงค Hand Protection

For incidental contact with the product wear chemical-resistant gloves (standard EN 374). The use of disposable gloves is acceptable provided that they are changed immediately after a splash or spill. Neoprene gloves are recommended.

๐Ÿ‘๏ธ Eye Protection

Use eye protection according to EN 166. Safety glasses with side shields.

๐Ÿ˜ท Respiratory Protection

No respiratory protection needed under normal use conditions. In case of insufficient ventilation, wear suitable respiratory equipment

๐Ÿฆบ Skin/Body Protection

Wear suitable protective clothing

๐ŸŒ Environmental Exposure Controls

Avoid release to the environment. Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for EVAPO-RUST?

The signal word for this substance is "no signal word".

What is the physical form of EVAPO-RUST?

EVAPO-RUST is a liquid with colourless to yellow. color. It has neutral. odor.

What is the solubility of EVAPO-RUST?

soluble in water.

What is EVAPO-RUST used for?

Rust remover

What is the melting point of EVAPO-RUST?

The melting point is Not applicable and the boiling point is > 100.