Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Adex-K
- Product Form
- Powder
- Synonyms
- None.
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Firefighting Powder for use on Class A, B, C and E fires.
Uses advised against
None known.
Manufacturers & Suppliers
UTC CCS Manufacturing Polska sp.z o.o.
manufacturer
ul.Kolejowa 24, 39-100 Ropczyce, Poland
0048 (17) 22 10 211
Emergency Contacts
Emergency Contact
112
Emergency Contact
0048 667 660 611
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Ammonium sulphate EC: 231-984-1 | 7783-20-2 | 64 - 70% | No |
| Mica | 12001-26-2 | 2% | No |
| Ammonium dihydrogenorthophosphate EC: 231-764-5 | 7722-76-1 | 20 - 23% | No |
Notes
All concentrations are in percent by weight unless ingredient is a gas. Gas concentrations are in percent by volume.
First Aid Measures
Emergency procedures for chemical exposure incidents
If symptomatic, move to fresh air. Get medical attention if symptoms persist.
Symptoms: Dust irritates the respiratory system, and may cause coughing and difficulties in breathing.
Wash area with soap and water. Get medical attention if irritation develops or persists.
Do not rub eyes. Flush thoroughly with water. If irritation occurs, get medical assistance.
Symptoms: Dust in the eyes
Rinse mouth thoroughly with water and give large amounts of milk or water to people not unconscious. Get medical attention if symptoms occur.
Immediate Medical Attention
Get medical attention if symptoms persist or occur.
Medical Treatment
Provide general supportive measures and treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
No specific measures are required as this product is a fire extinguishing medium.
Not applicable.
Not a fire hazard.
No specific precautions.
Firefighter Protection
Self-contained breathing apparatus, operated in positive pressure mode and full protective clothing must be worn in case of fire.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
For non-emergency personnel: Avoid inhalation of dust and contact with skin and eyes. For emergency responders: Avoid formation of dust. Use personal protection recommended in section 8 of the SDS.
Avoid discharge to the aquatic environment.
Vacuum up the spilled material.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid inhalation of dust and contact with skin and eyes. Wear appropriate personal protective equipment.
Store in original container. Store in a cool, dry, well-ventilated place. Store extinguisher in an upright position not more than three high. Read and follow manufacturer's recommendations.
Wash hands after handling. Observe good industrial hygiene practices.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide sufficient ventilation for operations causing dust formation. Observe occupational exposure limits and minimise the risk of exposure.
It is a good industrial hygiene practice to minimise skin contact. For prolonged or repeated skin contact use suitable protective gloves.
Wear approved safety goggles.
In case of inadequate ventilation or risk of inhalation of dust, use suitable respiratory equipment with particle filter (type P2). If engineering controls do not maintain airborne concentrations below recommended exposure limits (where applicable) or to an acceptable level (in countries where exposure limits have not been established), an approved respirator must be worn.
Wear suitable protective clothing. It is a good industrial hygiene practice to minimise skin contact.
Contain spills and prevent releases and observe national regulations on emissions.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal temperature conditions.
The product is stable and non reactive under normal conditions of use, storage and transport.
Hazardous polymerisation does not occur.
Temperatures above melting point. Contact with alkalis.
Strong acids. Strong bases. Strong oxidising agents. Alkali metals. Magnesium. Water.
Ammonia. Sulphur oxides. Oxides of phosphorus. Carbon oxides.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Dispose of waste and residues in accordance with local authority requirements.
Dispose of waste and residues in accordance with local authority requirements.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The product does not need to be labelled in accordance with EC directives or respective national laws. This Safety Data Sheet complies with the requirements of Regulation (EC) No 1907/2006.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is Adex-K known by?
Adex-K is also known as: None.
What is the hazard signal word for Adex-K?
The signal word is no signal word.
What is the physical form of Adex-K?
Adex-K is a solid. appearing as solid. fine powder. various. with various. color. It has odourless. odor.
What is the solubility of Adex-K?
Soluble in water, but silicon additive delays dissolution.
What is Adex-K used for?
Firefighting Powder for use on Class A, B, C and E fires.
What are the hazard statements for Adex-K?
This substance has 1 hazard statement:
- The mixture does not meet the criteria for classification.
What is the melting point of Adex-K?
The melting point is Not available. and the boiling point is Not applicable..