Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- ultraView Universal DAB Detection Kit
- Product Code
- 05269806001
Regulatory Identifiers
- CAS Number
- N/A
Manufacturers & Suppliers
Roche Diagnostics
manufacturer
9115 Hague Road, 46250 Indianapolis IN
1-800-428-5074
Emergency Contacts
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| hydrogen peroxide | 7722-84-1 | 1 - 5% | Yes |
| Tri-potassiumphosphate-trihydrate | 22763-03-7 | 1 - 5% | Yes |
| Polyethylene glycol | 25322-68-3 | 5 - 10% | Yes |
| biphenyl-3,3',4,4'-tetrayltetraammonium tetra-chloride | 7411-49-6 | 0.1 - 1% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. If unconscious place in recovery position and seek medical advice. If symptoms persist, call a physician.
If skin irritation persists, call a physician. If on skin, rinse well with water. If on clothes, remove clothes.
Symptoms: skin irritation
In the case of contact with eyes, rinse immediately with plenty of water and seek medical advice. Continue rinsing eyes during transport to hospital. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing. If eye irritation persists, consult a specialist.
Symptoms: Small amounts splashed into eyes can cause irreversible tissue damage and blindness.
Clean mouth with water and drink afterwards plenty of water. Keep respiratory tract clear. Do NOT induce vomiting. Do not give milk or alcoholic beverages. Never give anything by mouth to an unconscious person. If symptoms persist, call a physician. Take victim immediately to hospital. Rinse mouth with water.
Immediate Medical Attention
Take victim immediately to hospital.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
High volume water jet
Do not allow run-off from fire fighting to enter drains or water courses.
Firefighter Protection
Wear self-contained breathing apparatus for firefighting if necessary.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protective equipment. Refer to protective measures listed in sections 7 and 8.
Prevent product from entering drains. Prevent further leakage or spillage if safe to do so. If the product contaminates rivers and lakes or drains inform respective authorities.
Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust).
Materials: inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Do not breathe vapours/dust. Avoid exposure - obtain special instructions before use. Avoid contact with skin and eyes.
Normal measures for preventive fire protection.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No data available
Material: Protective gloves. Remarks: The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it. This recommendation is only valid for the product mentioned in the safety data sheet and provided by us and for the application specified by us. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time. The suitability for a specific workplace should be discussed with the producers of the protective gloves.
Eye wash bottle with pure water, Tightly fitting safety goggles, Wear face-shield and protective suit for abnormal processing problems.
In the case of vapour formation use a respirator with an approved filter.
impervious clothing, Choose body protection according to the amount and concentration of the dangerous substance at the work place.
Dispose of rinse water in accordance with local and national regulations. To prevent leaks or spillages from spreading, provide a suitable liquid retention system.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
No dangerous reaction known under conditions of normal use.
Reacts with the following substances: Acids, Bases, Oxidizing agents, Reducing agents, Metals. Do not allow to dry. No decomposition if stored and applied as directed.
No data available
Acids and bases, Oxidizing agents, Reducing agents, Metals
In case of fire hazardous decomposition products may be produced such as: Carbon oxides
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Send to a licensed waste management company.
The product should not be allowed to enter drains, water courses or the soil. Do not contaminate ponds, waterways or ditches with chemical or used container.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for ultraView Universal DAB Detection Kit?
The signal word is no signal word.
What is the physical form of ultraView Universal DAB Detection Kit?
ultraView Universal DAB Detection Kit is a liquid appearing as liquid with colourless color. It has slight odor.
What is the solubility of ultraView Universal DAB Detection Kit?
completely miscible
What is the melting point of ultraView Universal DAB Detection Kit?
The melting point is No data available and the boiling point is No data available.