NextSDS Logo
Safety Data Sheet EN

ultraView Universal DAB Detection Kit

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
ultraView Universal DAB Detection Kit
Product Code
05269806001

Regulatory Identifiers

CAS Number
N/A

Manufacturers & Suppliers

R

Roche Diagnostics

manufacturer

9115 Hague Road, 46250 Indianapolis IN

1-800-428-5074

Emergency Contacts

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
hydrogen peroxide 7722-84-1 1 - 5% Yes
Tri-potassiumphosphate-trihydrate 22763-03-7 1 - 5% Yes
Polyethylene glycol 25322-68-3 5 - 10% Yes
biphenyl-3,3',4,4'-tetrayltetraammonium tetra-chloride 7411-49-6 0.1 - 1% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. If unconscious place in recovery position and seek medical advice. If symptoms persist, call a physician.

Skin contact

If skin irritation persists, call a physician. If on skin, rinse well with water. If on clothes, remove clothes.

Symptoms: skin irritation

Eye contact

In the case of contact with eyes, rinse immediately with plenty of water and seek medical advice. Continue rinsing eyes during transport to hospital. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing. If eye irritation persists, consult a specialist.

Symptoms: Small amounts splashed into eyes can cause irreversible tissue damage and blindness.

Ingestion

Clean mouth with water and drink afterwards plenty of water. Keep respiratory tract clear. Do NOT induce vomiting. Do not give milk or alcoholic beverages. Never give anything by mouth to an unconscious person. If symptoms persist, call a physician. Take victim immediately to hospital. Rinse mouth with water.

Immediate Medical Attention

Take victim immediately to hospital.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Unsuitable media

High volume water jet

Specific hazards

Do not allow run-off from fire fighting to enter drains or water courses.

Firefighter Protection

Wear self-contained breathing apparatus for firefighting if necessary.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protective equipment. Refer to protective measures listed in sections 7 and 8.

Environmental

Prevent product from entering drains. Prevent further leakage or spillage if safe to do so. If the product contaminates rivers and lakes or drains inform respective authorities.

Cleanup methods

Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust).

Materials: inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Do not breathe vapours/dust. Avoid exposure - obtain special instructions before use. Avoid contact with skin and eyes.

Fire prevention

Normal measures for preventive fire protection.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No data available

Hands

Material: Protective gloves. Remarks: The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it. This recommendation is only valid for the product mentioned in the safety data sheet and provided by us and for the application specified by us. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time. The suitability for a specific workplace should be discussed with the producers of the protective gloves.

Eyes

Eye wash bottle with pure water, Tightly fitting safety goggles, Wear face-shield and protective suit for abnormal processing problems.

Respiratory

In the case of vapour formation use a respirator with an approved filter.

Skin/Body

impervious clothing, Choose body protection according to the amount and concentration of the dangerous substance at the work place.

Environmental

Dispose of rinse water in accordance with local and national regulations. To prevent leaks or spillages from spreading, provide a suitable liquid retention system.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
liquid
Colour
colourless
Colour Intensity
---
Form
---
Odor
slight
Odor Threshold
No data available
Ph
4.18
Melting Point
No data available
Boiling Point
No data available
Flash Point
does not flash
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No data available
Vapor Pressure
No data available
Vapor Density
---
Relative Density
No data available
Bulk Density
---
Density
1.1 g/cm3
Flammability
The product is not flammable.
Upper Explosive Limit
No data available
Lower Explosive Limit
No data available
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
No data available
Solubility
completely miscible
Partition Coefficient
No data available
Solubility In Water
completely miscible
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

No dangerous reaction known under conditions of normal use.

Hazardous reactions

Reacts with the following substances: Acids, Bases, Oxidizing agents, Reducing agents, Metals. Do not allow to dry. No decomposition if stored and applied as directed.

Avoid

No data available

Incompatible

Acids and bases, Oxidizing agents, Reducing agents, Metals

Decomposition

In case of fire hazardous decomposition products may be produced such as: Carbon oxides

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Send to a licensed waste management company.

Disposal

The product should not be allowed to enter drains, water courses or the soil. Do not contaminate ponds, waterways or ditches with chemical or used container.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for ultraView Universal DAB Detection Kit?

The signal word is no signal word.

What is the physical form of ultraView Universal DAB Detection Kit?

ultraView Universal DAB Detection Kit is a liquid appearing as liquid with colourless color. It has slight odor.

What is the solubility of ultraView Universal DAB Detection Kit?

completely miscible

What is the melting point of ultraView Universal DAB Detection Kit?

The melting point is No data available and the boiling point is No data available.