Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Papanicolaou's solution 3a polychromatic solution EA 31 for cytological cancer and cycle diagnosis
- Product Code
- 109271
Regulatory Identifiers
- CAS Number
- N/A
- REACH No.
- This product is a mixture. REACH Registration Number see section 3.
Identified Uses
In vitro diagnostic reagent, Reagent for analysis
Manufacturers & Suppliers
Merck KGaA
manufacturer
64271 Darmstadt, Germany
+49 6151 72-0
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
GHS08
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. Immediately call in physician. If breathing stops: immediately apply artificial respiration, if necessary also oxygen.
Wash off with plenty of water. Remove contaminated clothing. Consult a physician.
Rinse out with plenty of water with the eyelid held wide open. Call in ophthalmologist if necessary.
Move to fresh air. Make victim drink ethanol (e.g. 1 drinking glass of a 40% alcoholic beverage). Call a doctor immediately (mention methanol ingestion). Only in exceptional cases, if no medical care is available within one hour, induce vomiting (only in fully conscious persons) and make victim drink ethanol again (approx. 0.3 ml of a 40% alcoholic beverage/kg body weight/hour).
Immediate Medical Attention
No information available.
Medical Treatment
No information available.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Carbon dioxide (CO2), Foam, Dry powder
For this substance/mixture no limitations of extinguishing agents are given.
Combustible. Vapours are heavier than air and may spread along floors. Forms explosive mixtures with air at ambient temperatures. Pay attention to flashback. Development of hazardous combustion gases or vapours possible in the event of fire.
Remove container from danger zone and cool with water. Suppress (knock down) gases/vapours/mists with a water spray jet.
Firefighter Protection
Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not breathe vapours, aerosols. Avoid substance contact. Ensure adequate ventilation. Keep away from heat and sources of ignition. Evacuate the danger area, observe emergency procedures, consult an expert.
Do not let product enter drains. Risk of explosion.
Take up with liquid-absorbent and neutralising material (e.g. Chemizorb® H⁺, Merck Art. No. 101595).
Materials: liquid-absorbent and neutralising material (e.g. Chemizorb® H⁺, Merck Art. No. 101595)
Related Products
Similar products with comparable safety profiles
Papanicolaou's solution 3a polychromatic solution EA 31 for cytology
---
Papanicolaou's solution 2a Orange G solution (OG 6) for cytological cancer and cycle diagnosis
---
Papanicolaou's solution 1a Harris' hematoxylin solution for cytological cancer and cycle diagnosis
---
Giemsa's azur eosin methylene blue solution for microscopy
---
Giemsa's azur eosin methylene blue solution for microscopy
---
Giemsa's azur eosin methylene blue solution for microscopy
---
Giemsa's azur eosin methylene blue solution for microscopy
---
Giemsa Solution
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Work under hood. Do not inhale substance/mixture. Avoid generation of vapours/aerosols. Observe label precautions.
Keep container tightly closed in a dry and well-ventilated place. Keep locked up or in an area accessible only to qualified or authorised persons.
Immediately change contaminated clothing. Apply preventive skin protection. Wash hands and face after working with substance.
Keep away from open flames, hot surfaces and sources of ignition.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Technical measures and appropriate working operations should be given priority over the use of personal protective equipment. See section 7.1.
full contact: Glove material: butyl-rubber Glove thickness: 0,7 mm Break through time: - 480 min splash contact: Glove material: Viton (R) Glove thickness: 0,70 mm Break through time: - 120 min The protective gloves to be used must comply with the specifications of EC Directive 89/686/EEC and the related standard EN374, for example KCL 898 Butoject (full contact), KCL 890 Vitoject (splash contact). The breakthrough times stated above were determined by KCL in laboratory tests acc. to EN374 with samples of the recommended glove types. This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves (e.g., KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).
Safety glasses
required when vapours/aerosols are generated. Recommended Filter type: filter ABEK The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.
Flame retardant antistatic protective clothing
Do not let product enter drains. Risk of explosion.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature).
Vapours may form explosive mixture with air.
Risk of explosion with: chromium(VI) oxide, hydrogen peroxide, uranium hexafluoride, nitrogen dioxide, Nitric acid, Oxides of phosphorus, permanganic acid, perchloric acid, perchlorates, Fluorine, Ethylene oxide, chromyl chloride, halogen-halogen compounds, Strong oxidizing agents, alkali oxides, Alkaline earth metals, Alkali metals, potassium permanganate, sulphuric acid. Risk of ignition or formation of inflammable gases or vapours with: chromium(VI) oxide, hydrogen peroxide, uranium hexafluoride, nitrogen dioxide, Nitric acid, Oxides of phosphorus, permanganic acid, perchloric acid, perchlorates, Fluorine, Ethylene oxide, chromyl chloride, halogen-halogen compounds, Strong oxidizing agents, alkali oxides, Alkaline earth metals, Alkali metals, potassium permanganate, sulphuric acid.
Warming. A range from approx. 15 Kelvin below the flash point is to be rated as critical.
chromium(VI) oxide, hydrogen peroxide, uranium hexafluoride, nitrogen dioxide, Nitric acid, Oxides of phosphorus, permanganic acid, perchloric acid, perchlorates, Fluorine, Ethylene oxide, chromyl chloride, halogen-halogen compounds, Strong oxidizing agents, alkali oxides, Alkaline earth metals, Alkali metals, potassium permanganate, sulphuric acid
no information available
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
PBT/vPvB assessment not available as chemical safety assessment not required/not conducted.
12.1 Toxicity
12.2 Persistence and degradability
12.5 Results of PBT and vPvB assessment
12.7 Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
See www.retrologistik.com for processes regarding the return of chemicals and containers, or contact us there if you have further questions.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN 1992
- Shipping Name
- FLAMMABLE LIQUID, TOXIC, N.O.S. (CONT. METHANOL, ETHANOL)
- Transport Class
- 3
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Regulatory information regarding Seveso III, occupational restrictions, and chemical regulations.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Papanicolaou's solution 3a polychromatic solution EA 31 for cytological cancer and cycle diagnosis?
The signal word is danger.
What is the physical form of Papanicolaou's solution 3a polychromatic solution EA 31 for cytological cancer and cycle diagnosis?
Papanicolaou's solution 3a polychromatic solution EA 31 for cytological cancer and cycle diagnosis is a liquid with greenish-blue color. It has of ethanol odor.
What is Papanicolaou's solution 3a polychromatic solution EA 31 for cytological cancer and cycle diagnosis used for?
In vitro diagnostic reagent, Reagent for analysis
What are the hazard statements for Papanicolaou's solution 3a polychromatic solution EA 31 for cytological cancer and cycle diagnosis?
This substance has 3 hazard statements:
- H225: Highly flammable liquid and vapour.
- H302 + H312 + H332: Harmful if swallowed, in contact with skin or if inhaled
- H370: Causes damage to organs (Eyes).
What is the melting point of Papanicolaou's solution 3a polychromatic solution EA 31 for cytological cancer and cycle diagnosis?
The melting point is No information available. and the boiling point is No information available..