Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- KAPA HyperPlus (8rxn)
- Product Code
- 07962380001
Regulatory Identifiers
- CAS Number
- N/A
Manufacturers & Suppliers
Roche Diagnostics Deutschland GmbH
manufacturer
Sandhoferstrasse 116, 68305 Mannheim
+496217590
Emergency Contacts
Central Works Security
+49(0)621-759-2203
Mainz
+49(0)6131-19240
Munich
+49(0)89-19240
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. If unconscious place in recovery position and seek medical advice. If symptoms persist, call a physician.
If skin irritation persists, call a physician. If on skin, rinse well with water. If on clothes, remove clothes.
Immediately flush eye(s) with plenty of water. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing. If eye irritation persists, consult a specialist.
Clean mouth with water and drink afterwards plenty of water. Keep respiratory tract clear. Do not give milk or alcoholic beverages. Never give anything by mouth to an unconscious person. If symptoms persist, call a physician. Take victim immediately to hospital. Rinse mouth with water.
Medical Treatment
The first aid procedure should be established in consultation with the doctor responsible for industrial medicine.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
High volume water jet
No information available.
Standard procedure for chemical fires.
Firefighter Protection
Wear self-contained breathing apparatus for firefighting if necessary.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protective equipment. Refer to protective measures listed in sections 7 and 8.
Prevent product from entering drains. Prevent further leakage or spillage if safe to do so.
Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust). Keep in suitable, closed containers for disposal.
Materials: inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Do not breathe vapours/dust. Avoid exposure - obtain special instructions before use. Avoid contact with skin and eyes. For personal protection see section 8. Smoking, eating and drinking should be prohibited in the application area. Dispose of rinse water in accordance with local and national regulations.
Keep container tightly closed in a dry and well-ventilated place. Observe label precautions.
When using do not eat or drink. When using do not smoke. Wash hands before breaks and at the end of workday.
Normal measures for preventive fire protection.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No data available
Material: Protective gloves. Remarks: The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it. This recommendation is only valid for the product mentioned in the safety data sheet and provided by us and for the application specified by us. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time. The suitability for a specific workplace should be discussed with the producers of the protective gloves.
Eye wash bottle with pure water. Tightly fitting safety goggles
In the case of vapour formation use a respirator with an approved filter.
Impervious clothing. Choose body protection according to the amount and concentration of the dangerous substance at the work place.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
No dangerous reaction known under conditions of normal use.
Hazardous reactions: No decomposition if stored and applied as directed.
No data available
No data available
No data available
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Send to a licensed waste management company. Can be disposed as waste water, when in compliance with local regulations.
Do not contaminate ponds, waterways or ditches with chemical or used container. Send to a licensed waste management company.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
A Chemical Safety Assessment is not required for this substance when it is used in the specified applications.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for KAPA HyperPlus (8rxn)?
The signal word is warning.
What is the physical form of KAPA HyperPlus (8rxn)?
KAPA HyperPlus (8rxn) is a liquid appearing as liquid with colourless color. It has odourless odor.
What are the hazard statements for KAPA HyperPlus (8rxn)?
This substance has 1 hazard statement:
- H371: May cause damage to organs.
What is the melting point of KAPA HyperPlus (8rxn)?