Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Isobutanol for analysis EMSURE® ACS, Reag. Ph Eur
- Product Code
- 100984
- Chemical Name
- Isobutanol
Regulatory Identifiers
- CAS Number
- 78-83-1 Check regulations →
- REACH No.
- 01-2119484609-23-xxxx
Identified Uses
Reagent for analysis, Chemical production
Manufacturers & Suppliers
Merck KGaA
manufacturer
64271 Darmstadt, Germany
+49 6151 72-0
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS05
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| iso-butanol EC: 201-148-0 | 78-83-1 | 100% | Yes |
The Safety Data Sheets for catalogue items are available at www.merckgroup.com
Notes
Substance does not meet the criteria for PBT or vPvB according to Regulation (EC) No 1907/2006, Annex XIII.
First Aid Measures
Emergency procedures for chemical exposure incidents
fresh air. Call in physician.
Symptoms: Cough, Shortness of breath, respiratory paralysis, Dizziness, Unconsciousness, narcosis, inebriation, Headache, Coma
Take off immediately all contaminated clothing. Rinse skin with water/ shower.
Symptoms: Irritation and corrosion
rinse out with plenty of water. Immediately call in ophthalmologist. Remove contact lenses.
Symptoms: Irritation and corrosion, Risk of serious damage to eyes, Risk of corneal clouding.
caution if victim vomits. Risk of aspiration! Keep airways free. Pulmonary failure possible after aspiration of vomit. Call a physician immediately.
Immediate Medical Attention
Call in physician. Immediately call in ophthalmologist. Call a physician immediately.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Carbon dioxide (CO2), Foam, Dry powder
For this substance/mixture no limitations of extinguishing agents are given.
Combustible. Vapours are heavier than air and may spread along floors. Forms explosive mixtures with air at elevated temperatures. Development of hazardous combustion gases or vapours possible in the event of fire.
Remove container from danger zone and cool with water.
Firefighter Protection
Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not breathe vapours, aerosols. Avoid substance contact. Ensure adequate ventilation. Keep away from heat and sources of ignition. Evacuate the danger area, observe emergency procedures, consult an expert.
Do not let product enter drains. Risk of explosion.
Take up with liquid-absorbent material (e.g. Chemizorb®). Dispose of properly. Clean up affected area.
Materials: liquid-absorbent material (e.g. Chemizorb®)
Related Products
Similar products with comparable safety profiles
1-Butanol for analysis EMSURE® ACS, ISO, Reag. Ph Eur
CAS: 71-36-3
tert-Butanol for analysis EMSURE® ACS
CAS: 75-65-0
Ethyl acetate for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 141-78-6
n-Butyl acetate for analysis EMSURE®
CAS: 123-86-4
Chloroform for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 67-66-3
Ethanolamine for analysis EMSURE®
CAS: 141-43-5
Ethanol 96% EMSURE® Reag. Ph Eur
CAS: 64-17-5
Sodium acetate trihydrate for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 6131-90-4
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Work under hood. Do not inhale substance/mixture. Avoid generation of vapours/aerosols.
Keep container tightly closed in a dry and well-ventilated place. Keep away from heat and sources of ignition.
Immediately change contaminated clothing. Apply preventive skin protection. Wash hands and face after working with substance.
Keep away from open flames, hot surfaces and sources of ignition. Take precautionary measures against static discharge.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Technical measures and appropriate working operations should be given priority over the use of personal protective equipment. See section 7.1.
full contact: Glove material: Nitrile rubber, Glove thickness: 0,40 mm, Break through time: 480 min; splash contact: Glove material: Nitrile rubber, Glove thickness: 0,11 mm, Break through time: 10 min. The protective gloves to be used must comply with the specifications of EC Directive 89/686/EEC and the related standard EN374, for example KCL 730 Camatril® -Velours (full contact), KCL 741 Dermatril® L (splash contact).
Tightly fitting safety goggles
required when vapours/aerosols are generated. Recommended Filter type: Filter A (acc. to DIN 3181) for vapours of organic compounds. The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer.
Flame retardant antistatic protective clothing.
Do not let product enter drains. Risk of explosion.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature).
Vapour/air-mixtures are explosive at intense warming.
Exothermic reaction with: Acid chlorides, strong reducing agents. Risk of ignition or formation of inflammable gases or vapours with: chromium(VI) oxide, Strong oxidizing agents, Aluminium. Violent reactions possible with: Alkali metals, Alkaline earth metals
Heating.
Aluminium, rubber, various plastics
no information available
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
See www.retrologistik.com for processes regarding the return of chemicals and containers, or contact us there if you have further questions.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1212
- Shipping Name
- ISOBUTANOL
- Transport Class
- 3
- Packing Group
- III
yes
yes
no
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Major Accident Hazard SEVESO III Legislation FLAMMABLE LIQUIDS P5c. Occupational restrictions: Take note of Dir 94/33/EC on the protection of young people at work.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Isobutanol for analysis EMSURE® ACS, Reag. Ph Eur?
The signal word is danger.
What is the physical form of Isobutanol for analysis EMSURE® ACS, Reag. Ph Eur?
Isobutanol for analysis EMSURE® ACS, Reag. Ph Eur is a liquid with colourless color. It has alcohol-like odor.
What is Isobutanol for analysis EMSURE® ACS, Reag. Ph Eur used for?
Reagent for analysis, Chemical production
What are the hazard statements for Isobutanol for analysis EMSURE® ACS, Reag. Ph Eur?
This substance has 5 hazard statements:
- H226: Flammable liquid and vapour.
- H315: Causes skin irritation.
- H318: Causes serious eye damage.
- H335: May cause respiratory irritation.
- H336: May cause drowsiness or dizziness.
What is the melting point of Isobutanol for analysis EMSURE® ACS, Reag. Ph Eur?
The melting point is -108 °C and the boiling point is 106 - 108 °C.