Chemical Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
European Community number - used for regulatory compliance in EU/EEA
Registration, Evaluation, Authorisation and Restriction of Chemicals - EU regulation compliance
Uses Information
Overview
Isobutanol for analysis EMSURE ACS,Reag. Ph Eur (CAS: 78-83-1 ) commonly used reagent for analysis, chemical production.
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
Hazard Classifications
GHS Hazard Pictograms & Safety Symbols
GHS02
GHS07
GHS05
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
- H226: Flammable liquid and vapour.
- H315: Causes skin irritation.
- H318: Causes serious eye damage.
- H335: May cause respiratory irritation.
- H336: May cause drowsiness or dizziness.
Precautionary Statements
- P210: Keep away from heat.
- P280: Wear eye protection.
- P302 + P352: IF ON SKIN: Wash with plenty of soap and water.
- P305 + P351 + P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P313: Get medical advice/ attention.
Chemical Manufacturers & Supply Chain
Authorized suppliers, manufacturers, and distribution network information
Merck KGaA
undefined
64271 Darmstadt * Germany
DE
+49 6151 72-0
24/7 Emergency Response & Poison Control
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
SubstanceChemical Components & Hazardous Substances
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| 2-Metylopropan-1-ol (izobutanol, alkohol izobutylowy) EC: 201-148-0 | 78-83-1 | 100% | โ ๏ธ Hazardous |
Additional Information
The Safety Data Sheets for catalogue items are available at www.merckgroup.com
Composition Notes
Substance does not meet the criteria for PBT or vPvB according to Regulation (EC) No 1907/2006, Annex XIII.
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
๐ซ Inhalation Exposure
fresh air. Call in physician.
๐๏ธ Skin Contact
Take off immediately all contaminated clothing. Rinse skin with water/shower.
๐๏ธ Eye Contact
rinse out with plenty of water. Immediately call in ophthalmologist. Remove contact lenses.
Symptoms:
Risk of serious damage to eyes. Risk of corneal clouding.
๐ฝ๏ธ Ingestion/Swallowing
caution if victim vomits. Risk of aspiration! Keep airways free. Pulmonary failure possible after aspiration of vomit. Call a physician immediately.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Exposure Controls & Personal Protective Equipment (PPE)
Occupational exposure limits, engineering controls, and required safety equipment
๐ญ Engineering Controls
Technical measures and appropriate working operations should be given priority over the use of personal protective equipment. See section 7.1.
๐งค Hand Protection
full contact: Glove material: Nitrile rubber Glove thickness: 0,40 mm Break through time: 480 min splash contact: Glove material: Nitrile rubber Glove thickness: 0,11 mm Break through time: 10 min The protective gloves to be used must comply with the specifications of EC Directive 89/686/EEC and the related standard EN374, for example KCL 730 Camatril -Velours (full contact), KCL 741 Dermatril L (splash contact). The breakthrough times stated above were determined by KCL in laboratory tests acc. to EN374 with samples of the recommended glove types. This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).
๐๏ธ Eye Protection
Tightly fitting safety goggles
๐ท Respiratory Protection
required when vapours/aerosols are generated. Recommended Filter type: Filter A (acc. to DIN 3181) for vapours of organic compounds The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.
๐ฆบ Skin/Body Protection
Flame retardant antistatic protective clothing.
๐ Environmental Exposure Controls
Do not let product enter drains.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
๐ท๏ธ UN Number
UN 1212
๐ฆ Proper Shipping Name
ISOBUTANOL
โ ๏ธ Transport Hazard Class
3
๐ Packing Group
III
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What other names is Isobutanol for analysis EMSURE ACS,Reag. Ph Eur known by?
Isobutanol for analysis EMSURE ACS,Reag. Ph Eur is also known as: Isobutyl alcohol
What is the hazard signal word for Isobutanol for analysis EMSURE ACS,Reag. Ph Eur?
The signal word for this substance is "danger".
What is the physical form of Isobutanol for analysis EMSURE ACS,Reag. Ph Eur?
Isobutanol for analysis EMSURE ACS,Reag. Ph Eur is a liquid with colourless color. It has alcohol-like odor.
What is Isobutanol for analysis EMSURE ACS,Reag. Ph Eur used for?
Reagent for analysis, Chemical production
What are the hazard statements for Isobutanol for analysis EMSURE ACS,Reag. Ph Eur?
This substance has 5 hazard statements: H226: Flammable liquid and vapour. H315: Causes skin irritation. H318: Causes serious eye damage. H335: May cause respiratory irritation. H336: May cause drowsiness or dizziness.
What is the melting point of Isobutanol for analysis EMSURE ACS,Reag. Ph Eur?
The melting point is -108 C and the boiling point is 106 - 108 C.