NextSDS Logo
Safety Data Sheet EN

ISE Internal Standard Gen.2

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
ISE Internal Standard Gen.2
Product Code
04880455190

Regulatory Identifiers

CAS Number
N/A

Identified Uses

For professional users only.

Manufacturers & Suppliers

R

Roche Diagnostics Limited

national supplier

Charles Avenue, Burgess Hill, RH15 9RY West Sussex, United Kingdom

+44 1444 256000

Emergency Contacts

Roche Diagnostics Ltd. Health, Safety & Environment

+44 1444 256500

Roche Diagnostics Ltd. Health, Safety & Environment

+44 7802 260498

Roche Diagnostics Ltd. Product Safety / Vigilance

+44 1444 256561

Roche Diagnostics Ltd. Product Safety / Vigilance

+44 7710 391653

NPIS

+44 844 892 0111

NHS Direct

+44 845 4647

NHS 24

+44 8454 242424

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
reaction mass of 5-chloro-2-methyl-2H-isothiazol-3-one and 2-methyl-2H-isothiazol-3-one (3:1) 55965-84-9 0.0002 - 0.0015% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. If unconscious, place in recovery position and seek medical advice. If symptoms persist, call a physician.

Skin contact

If on skin, rinse well with water.

Eye contact

Immediately flush eye(s) with plenty of water. Remove contact lenses. Protect unharmed eye. If eye irritation persists, consult a specialist.

Ingestion

Keep respiratory tract clear. Do not give milk or alcoholic beverages. Never give anything by mouth to an unconscious person. If symptoms persist, call a physician. Rinse mouth with water.

Medical Treatment

The first aid procedure should be established in consultation with the doctor responsible for industrial medicine.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Specific hazards

No information available.

Instructions

Standard procedure for chemical fires.

Firefighter Protection

Wear self-contained breathing apparatus for firefighting if necessary.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Refer to protective measures listed in sections 7 and 8.

Environmental

Local authorities should be advised if significant spillages cannot be contained.

Cleanup methods

Wipe up with absorbent material (e.g. cloth, fleece). Keep in suitable, closed containers for disposal.

Materials: absorbent material (e.g. cloth, fleece)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

For personal protection see section 8. Smoking, eating and drinking should be prohibited in the application area.

Storage

See label, package insert or internal guidelines

Hygiene

Handle in accordance with good industrial hygiene and safety practice.

Fire prevention

Normal measures for preventive fire protection.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No data available

Hands

Material: In case of contact through splashing: Nitrile rubber, Break through time: > 30 min, Glove thickness: > 0,11 mm. Material: In case of full contact: butyl-rubber, Break through time: > 480 min, Glove thickness: > 0,4 mm. The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374.

Eyes

Safety glasses. Use eye protection according to EN 166.

Respiratory

No personal respiratory protective equipment normally required.

Skin/Body

Protective suit

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
No data available
Colour Intensity
---
Form
---
Odor
No data available
Odor Threshold
No data available
Ph
7,6
Melting Point
No data available
Boiling Point
No data available
Flash Point
does not flash
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No data available
Vapor Pressure
No data available
Vapor Density
---
Relative Density
No data available
Bulk Density
---
Density
---
Flammability
---
Upper Explosive Limit
No data available
Lower Explosive Limit
No data available
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
No data available
Solubility
---
Partition Coefficient
No data available
Solubility In Water
completely miscible
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
No data available
Kinematic Viscosity
No data available
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

No dangerous reaction known under conditions of normal use.

Hazardous reactions

Stable under recommended storage conditions. No hazards to be specially mentioned.

Avoid

No data available

Incompatible

No data available

Decomposition

No data available

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Can be disposed as waste water, when in compliance with local regulations.

Disposal

Can be disposed as waste water, when in compliance with local regulations.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessments for all substances in this product are either Complete or Not applicable.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for ISE Internal Standard Gen.2?

The signal word is no signal word.

What is the physical form of ISE Internal Standard Gen.2?

ISE Internal Standard Gen.2 is a liquid with no data available color. It has no data available odor.

What is ISE Internal Standard Gen.2 used for?

For professional users only.

What is the melting point of ISE Internal Standard Gen.2?

The melting point is No data available and the boiling point is No data available.