NextSDS Logo
Safety Data Sheet EN

Internal Standard

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Internal Standard
Product Code
2024

Regulatory Identifiers

CAS Number
N/A

Identified Uses

In vitro diagnostics, PC21 Laboratory chemicals, PROC15 Use as laboratory reagent

Manufacturers & Suppliers

Chromsystems Instruments & Chemicals GmbH logo

Chromsystems Instruments & Chemicals GmbH

manufacturer

Am Haag 12, 82166 Gräfelfing, Germany

+49 89 18930-0

http://www.chromsystems.com

Emergency Contacts

advisory service

+49 30 19240

DE, EN

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Met. Corr. Cat. 1 H290

GHS Pictograms

GHS05 - Corrosive

GHS05

GHS07 - Health hazard

GHS07

Hazard Statements

H290 May be corrosive to metals.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Aqueous solution

Chemical Name CAS Number Concentration Hazardous
hydrogen chloride EC: 231-595-7 7647-01-0 1 - 2.5% Yes

For the wording of the listed risk phrases refer to section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air.

Skin contact

Rinse with water.

Eye contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

Ingestion

Rinse out mouth and then drink plenty of water. If symptoms persist consult doctor.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

The product itself is non-combustible. Use fire extinguishing methods suitable to surrounding conditions.

Specific hazards

In case of fire, the following can be released: Hydrogen chloride (HCl)

Firefighter Protection

Wear self-contained respiratory protective device.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Do not allow to enter sewers/ surface or ground water.

Cleanup methods

Absorb with liquid-binding material (sand, diatomite, universal binders). Dispose of the material collected according to regulations.

Materials: sand, diatomite, universal binders

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

No special measures required.

Storage

Store at +2 to +8 °C.

Fire prevention

The product is not flammable.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Additional information about design of technical facilities: No further data; see item 7.

Hands

Protective gloves. The protective gloves to be used must comply with the specifications of EC Directive 89/686/EEC and the related standard EN374. For the permanent contact gloves made of the following materials are suitable: Nitrile rubber, NBR. Recommended thickness of the material: ≥ 0.11 mm. Penetration time: > 480 min. As protection from splashes gloves made of the following materials are suitable: Nitrile rubber, NBR. Recommended thickness of the material: ≥ 0.11 mm. Penetration time: > 480 min.

Eyes

Tightly sealed goggles

Respiratory

Use suitable respiratory protective device only when aerosol or mist is formed. Filter A/P2

Skin/Body

Light weight protective clothing

Environmental

Do not empty into drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Solidification Point
---
Relative Density
---
Dynamic Viscosity
---
Boiling Point
Undetermined.
Form
Fluid
Evaporation Rate
---
Crystallisation Point
---
Odor Threshold
---
Colour Intensity
---
Density
Not determined.
Solubility In Water
Fully miscible.
Physical State
Fluid
Ph
< 1
Flash Point
Not applicable.
Bulk Density
---
Kinematic Viscosity
---
Properties Status
---
Softening Point
---
Molecular Weight
---
Cloud Point
---
Flammability
Not applicable.
Decomposition Temperature
---
Voc Content
---
Partition Coefficient
---
Lower Explosive Limit
---
Auto Ignition Temperature
Product is not selfigniting.
Melting Point
Undetermined.
Relative Evaporation Rate
---
Metal Corrosion
---
Solubility
Fully miscible.
Odor
Odourless
Vapor Density
---
Freezing Point
---
Vapor Pressure
---
Solubility In Fat
---
Upper Explosive Limit
---
Colour
Colourless
Appearance
Form: Fluid, Colour: Colourless
State Under Standard Conditions
---
Physical State Data
liquid
Explosive Limits
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Reactivity

Corrosive in contact with metals

Hazardous reactions

Reacts with metals forming hydrogen.

Avoid

No further relevant information available.

Incompatible

Metals

Decomposition

Hydrogen chloride (HCl)

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Must not be disposed together with household garbage. Do not allow product to reach sewage system. Product residues are to be disposed of in compliance with Directive 2008/98/EC on Waste and national and local requirements, e.g. in a suitable incineration plant.

Disposal

Leave chemicals in original containers. Transfer small quantities to approved transport containers.

Waste Codes

16 05 06* laboratory chemicals, consisting of or containing dangerous substances, including mixtures of laboratory chemicals EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN1789
Shipping Name
HYDROCHLORIC ACID, solution
Transport Class
8
Packing Group
III
ADR

Warning: Corrosive substances.

IMDG

Warning: Corrosive substances.

IATA

Warning: Corrosive substances.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

No further relevant information available.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Internal Standard?

The signal word is warning.

What is the physical form of Internal Standard?

Internal Standard is a fluid appearing as form: fluid, colour: colourless with colourless color. It has odourless odor.

What is the solubility of Internal Standard?

Fully miscible.

What is Internal Standard used for?

In vitro diagnostics, PC21 Laboratory chemicals, PROC15 Use as laboratory reagent

What are the hazard statements for Internal Standard?

This substance has 1 hazard statement:

  • H290: May be corrosive to metals.

What is the melting point of Internal Standard?

The melting point is Undetermined. and the boiling point is Undetermined..