NextSDS Logo
Safety Data Sheet EN

Hematoxylin cryst. (C.I. 75290) for microscopy

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Hematoxylin cryst. (C.I. 75290) for microscopy
Product Code
104302

Regulatory Identifiers

CAS Number
N/A
REACH No.
A registration number is not available for this substance as the substance or its use are exempted from registration according to Article 2 REACH Regulation (EC) No 1907/2006, the annual tonnage does not require a registration or the registration is envisaged for a later registration deadline.

Identified Uses

In vitro diagnostic reagent, Reagent for analysis For additional information on uses please refer to the Merck Chemicals portal (www.merck-chemicals.com).

Manufacturers & Suppliers

M

Merck KGaA

manufacturer

64271 Darmstadt, Germany

+49 6151 72-0

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
Hematoxylin EC: 208-237-3 517-28-2 --- No

Notes

No components that are liable to disclose according to Regulation (EC) No. 1907/2006.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

fresh air.

Skin contact

wash off with plenty of water. Remove contaminated clothing.

Eye contact

rinse out with plenty of water.

Ingestion

make victim drink water (two glasses at most). Consult doctor if feeling unwell.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water, Foam, Carbon dioxide (CO2), Dry powder

Unsuitable media

For this substance/mixture no limitations of extinguishing agents are given.

Specific hazards

Development of hazardous combustion gases or vapours possible in the event of fire.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid inhalation of dusts. Evacuate the danger area, observe emergency procedures, consult an expert.

Environmental

Do not let product enter drains.

Cleanup methods

Take up dry. Clean up affected area.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Observe label precautions.

Storage

Tightly closed. Dry. Store at +5°C to +30°C.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Technical measures and appropriate working operations should be given priority over the use of personal protective equipment. See section 7.1.

Hands

full contact: Glove material: Nitrile rubber, Glove thickness: 0,11 mm, Break through time: > 480 min; splash contact: Glove material: Nitrile rubber, Glove thickness: 0,11 mm, Break through time: > 480 min. The protective gloves to be used must comply with the specifications of EC Directive 89/686/EEC and the related standard EN374, for example KCL 741 Dermatril® L (full contact), KCL 741 Dermatril® L (splash contact). The breakthrough times stated above were determined by KCL in laboratory tests acc. to EN374 with samples of the recommended glove types.

Eyes

Safety glasses

Respiratory

required when dusts are generated. Recommended Filter type: Filter P 1 (acc. to DIN 3181) for solid particles of inert substances. The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

Skin/Body

Protective clothing needs to be selected specifically for the workplace, depending on concentrations and quantities of the hazardous substances handled. The chemical resistance of the protective equipment should be enquired at the respective supplier.

Environmental

Do not let product enter drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Cloud Point
---
Flammability
No information available.
Density
---
Lower Explosive Limit
No information available.
Relative Density
No information available.
Freezing Point
---
Bulk Density
ca.500 kg/m³
Physical State Data
solid
Decomposition Temperature
ca.120 °C Elimination of water of crystallisation 240 °C
Crystallisation Point
---
Metal Corrosion
---
Odor Threshold
No information available.
Solubility
---
Kinematic Viscosity
---
Melting Point
ca. 140 °C
Relative Evaporation Rate
---
Molecular Weight
---
Flash Point
No information available.
Boiling Point
No information available.
Solubility In Fat
---
Voc Content
---
Dynamic Viscosity
No information available.
Explosive Limits
---
Solidification Point
---
Auto Ignition Temperature
No information available.
Solubility In Water
at 90 °C soluble; at 20 °C slightly soluble
Form
solid
Physical State
solid
Properties Status
---
Evaporation Rate
No information available.
State Under Standard Conditions
---
Colour
beige
Softening Point
---
Appearance
---
Vapor Pressure
No information available.
Colour Intensity
---
Partition Coefficient
No information available.
Upper Explosive Limit
No information available.
Vapor Density
---
Odor
odourless
Ph
No information available.
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Sensitivity to light. Sensitive to air. The product is chemically stable under standard ambient conditions (room temperature).

Reactivity

The following applies in general to flammable organic substances and preparations: in correspondingly fine distribution, when whirled up a dust explosion potential may generally be assumed.

Hazardous reactions

Strong oxidizing agents

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

See www.retrologistik.com for processes regarding the return of chemicals and containers, or contact us there if you have further questions.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The Safety Data Sheets for catalogue items are available at www.merck-chemicals.com

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Hematoxylin cryst. (C.I. 75290) for microscopy?

The signal word is no signal word.

What is the physical form of Hematoxylin cryst. (C.I. 75290) for microscopy?

Hematoxylin cryst. (C.I. 75290) for microscopy is a solid with beige color. It has odourless odor.

What is Hematoxylin cryst. (C.I. 75290) for microscopy used for?

In vitro diagnostic reagent, Reagent for analysis For additional information on uses please refer to the Merck Chemicals portal (www.merck-chemicals.com).

What is the melting point of Hematoxylin cryst. (C.I. 75290) for microscopy?

The melting point is ca. 140 °C and the boiling point is No information available..