NextSDS Logo
He

Hematoxylin cryst. (C.I. 75290) for microscopy

NO SIGNAL WORD solid SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Hematoxylin cryst. (C.I. 75290) for microscopy
Product Code
104302

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
In vitro diagnostic reagent, Reagent for analysis

Overview

Hematoxylin cryst. (C.I. 75290) for microscopy commonly used in vitro diagnostic reagent, reagent for analysis.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Merck KGaA company logo - Safety Data Sheet supplier organization

Merck KGaA

manufacturer

64271 Darmstadt, Germany

DE

+49 6151 72-0

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
hematoxyline
EC: 208-237-3
517-28-2 Not specified Non-hazardous

Composition Notes

No components that are liable to disclose according to Regulation (EC) No. 1907/2006.

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

fresh air.

Skin Contact

wash off with plenty of water. Remove contaminated clothing.

Eye Contact

rinse out with plenty of water.

Ingestion/Swallowing

make victim drink water (two glasses at most). Consult doctor if feeling unwell.

Immediate Medical Attention Required

No information available.

Medical Treatment

No information available.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Molecular Weight
Not available
Odor Threshold
No information available.
Explosive Limits
Not available
Upper Explosive Limit
No information available.
Metal Corrosion
Not available
Freezing Point
Not available
Flammability
No information available.
State Under Standard Conditions
Not available
Solidification Point
Not available
Bulk Density
ca.500 kg/m
Solubility
Not available
Boiling Point
No information available.
Critical Property
Odor
odourless
Density
Not available
Solubility In Water
at 90 C soluble at 20 C slightly soluble
Vapor Density
Not available
Relative Evaporation Rate
Not available
Physical State
solid
Critical Property
Solubility In Fat
Not available
Relative Density
No information available.
Ph
No information available.
Form
solid
Softening Point
Not available
Cloud Point
Not available
Appearance
Not available
Kinematic Viscosity
Not available
Colour Intensity
Not available
Physical State Data
solid
Evaporation Rate
No information available.
Lower Explosive Limit
No information available.
Colour
beige
Auto Ignition Temperature
No information available.
Dynamic Viscosity
No information available.
Melting Point
ca. 140 C Elimination of water of crystallisation
Critical Property
Crystallisation Point
Not available
Decomposition Temperature
ca.120 C Elimination of water of crystallisation 240 C
Voc Content
Not available
Properties Status
Not available
Partition Coefficient
No information available.
Flash Point
No information available.
Critical Property
Vapor Pressure
No information available.
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Technical measures and appropriate working operations should be given priority over the use of personal protective equipment. See section 7.1.

Hand Protection

full contact: Glove material: Nitrile rubber Glove thickness: 0,11 mm Break through time: - 480 min splash contact: Glove material: Nitrile rubber Glove thickness: 0,11 mm Break through time: - 480 min The protective gloves to be used must comply with the specifications of EC Directive 89/686/EEC and the related standard EN374, for example KCL 741 Dermatril L (full contact), KCL 741 Dermatril L (splash contact). The breakthrough times stated above were determined by KCL in laboratory tests acc. to EN374 with samples of the recommended glove types. This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).

Eye Protection

Safety glasses

Respiratory Protection

required when dusts are generated. Recommended Filter type: Filter P 1 (acc. to DIN 3181) for solid particles of inert substances The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

Skin/Body Protection

Protective clothing needs to be selected specifically for the workplace, depending on concentrations and quantities of the hazardous substances handled. The chemical resistance of the protective equipment should be enquired at the respective supplier.

Environmental Exposure Controls

Do not let product enter drains.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Hematoxylin cryst. (C.I. 75290) for microscopy?

The signal word for this substance is "no signal word".

What is the physical form of Hematoxylin cryst. (C.I. 75290) for microscopy?

Hematoxylin cryst. (C.I. 75290) for microscopy is a solid with beige color. It has odourless odor.

What is Hematoxylin cryst. (C.I. 75290) for microscopy used for?

In vitro diagnostic reagent, Reagent for analysis

What is the melting point of Hematoxylin cryst. (C.I. 75290) for microscopy?

The melting point is ca. 140 C Elimination of water of crystallisation and the boiling point is No information available..