NextSDS Logo
Safety Data Sheet EN

HPV 16 mRNA Probe

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
HPV 16 mRNA Probe
Product Code
07658834001

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Laboratory chemicals, Refer to product literature for further details.

Manufacturers & Suppliers

R

Roche Diagnostics Deutschland GmbH

manufacturer

Sandhoferstrasse 116, 68305 Mannheim, Deutschland

+496217590

Emergency Contacts

Werkschutzzentrale Roche Diagnostics GmbH

+49(0)621-759-2203

Mainz

+49(0)6131-19240

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Carc. Cat. 2 H351
Repr. Cat. 1B H360D
STOT RE Cat. 2 H373

GHS Pictograms

GHS08 - Serious health hazard

GHS08

Hazard Statements

H351 Suspected of causing cancer.
H360D May damage the unborn child.
H373 May cause damage to organs through prolonged or repeated exposure.

Precautionary Statements

P201 Obtain special instructions before use.
P202 Do not handle until all safety precautions have been read and understood.
P260 Do not breathe mist or vapours.
P280 Wear protective gloves/ protective clothing/ eye protection/ face protection/ hearing protection.
P308 + P313 IF exposed or concerned: Get medical advice/ attention.
P501 Dispose of contents/ container to an approved waste disposal plant.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
formamide EC: 200-842-0 75-12-7 30 - 50% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. If unconscious, place in recovery position and seek medical advice. If symptoms persist, call a physician.

Skin contact

If on skin, rinse well with water.

Eye contact

Flush eyes with water as a precaution. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing. If eye irritation persists, consult a specialist.

Ingestion

Keep respiratory tract clear. Do not give milk or alcoholic beverages. Never give anything by mouth to an unconscious person. If symptoms persist, call a physician. Take victim immediately to hospital.

Immediate Medical Attention

Take victim immediately to hospital.

Medical Treatment

The first aid procedure should be established in consultation with the doctor responsible for industrial medicine.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Unsuitable media

High volume water jet

Specific hazards

Do not allow run-off from fire fighting to enter drains or water courses.

Firefighter Protection

Wear self-contained breathing apparatus for firefighting if necessary.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protective equipment. Refer to protective measures listed in sections 7 and 8.

Environmental

Prevent product from entering drains. Prevent further leakage or spillage if safe to do so. Local authorities should be advised if significant spillages cannot be contained.

Cleanup methods

Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust). Keep in suitable, closed containers for disposal.

Materials: inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Do not breathe vapours/dust. Avoid exposure - obtain special instructions before use. Avoid contact with skin and eyes. For personal protection see section 8. Smoking, eating and drinking should be prohibited in the application area. Dispose of rinse water in accordance with local and national regulations.

Storage

Keep container tightly closed in a dry and well-ventilated place.

Hygiene

When using do not eat or drink. When using do not smoke. Wash hands before breaks and at the end of workday.

Fire prevention

Normal measures for preventive fire protection.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No data available

Hands

In case of contact through splashing: Material: Nitrile rubber, Break through time: > 30 min, Glove thickness: > 0,11 mm. In case of full contact: Material: butyl-rubber, Break through time: > 480 min, Glove thickness: > 0,4 mm. The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it.

Eyes

Use eye protection according to EN 166. Eye wash bottle with pure water. Tightly fitting safety goggles.

Respiratory

In the case of vapour formation use a respirator with an approved filter.

Skin/Body

Impervious clothing. Choose body protection according to the amount and concentration of the dangerous substance at the work place.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Relative Density
No data available
Solubility In Fat
---
Odor Threshold
No data available
Decomposition Temperature
No data available
Molecular Weight
---
Colour Intensity
---
Bulk Density
---
State Under Standard Conditions
---
Crystallisation Point
---
Dynamic Viscosity
No data available
Auto Ignition Temperature
No data available
Properties Status
---
Boiling Point
No data available
Colour
No data available
Odor
No data available
Voc Content
---
Appearance
---
Cloud Point
---
Upper Explosive Limit
No data available
Kinematic Viscosity
No data available
Solubility In Water
completely miscible
Softening Point
---
Partition Coefficient
No data available
Evaporation Rate
No data available
Vapor Density
---
Freezing Point
---
Solidification Point
---
Flash Point
does not flash
Flammability
Does not sustain combustion.
Melting Point
No data available
Lower Explosive Limit
No data available
Ph
7,4
Solubility
---
Relative Evaporation Rate
---
Metal Corrosion
---
Physical State Data
liquid
Vapor Pressure
No data available
Density
1,19 g/cm3
Explosive Limits
---
Physical State
liquid
Form
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

No dangerous reaction known under conditions of normal use.

Hazardous reactions

No decomposition if stored and applied as directed.

Avoid

No data available

Incompatible

No data available

Decomposition

No data available

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Send to a licensed waste management company. Can be disposed as waste water, when in compliance with local regulations.

Disposal

Do not contaminate ponds, waterways or ditches with chemical or used container. Send to a licensed waste management company.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessments for all substances in this product are either Complete or Not applicable.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for HPV 16 mRNA Probe?

The signal word is danger.

What is the physical form of HPV 16 mRNA Probe?

HPV 16 mRNA Probe is a liquid with no data available color. It has no data available odor.

What is HPV 16 mRNA Probe used for?

Laboratory chemicals, Refer to product literature for further details.

What are the hazard statements for HPV 16 mRNA Probe?

This substance has 3 hazard statements:

  • H351: Suspected of causing cancer.
  • H360D: May damage the unborn child.
  • H373: May cause damage to organs through prolonged or repeated exposure.

What is the melting point of HPV 16 mRNA Probe?

The melting point is No data available and the boiling point is No data available.