Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- HPV 18 mRNA Probe
- Product Code
- 07658842001
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Laboratory chemicals, Refer to product literature for further details.
Manufacturers & Suppliers
Roche Diagnostics Deutschland GmbH
manufacturer
Sandhoferstrasse 116, 68305 Mannheim, Deutschland
+496217590
Emergency Contacts
Werkschutzzentrale Roche Diagnostics GmbH
+49(0)621-759-2203
Giftnotruf: Mainz
+49(0)6131-19240
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| formamide EC: 200-842-0 | 75-12-7 | 30 - 50% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. If unconscious, place in recovery position and seek medical advice. If symptoms persist, call a physician.
If on skin, rinse well with water.
Flush eyes with water as a precaution. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing. If eye irritation persists, consult a specialist.
Keep respiratory tract clear. Do not give milk or alcoholic beverages. Never give anything by mouth to an unconscious person. If symptoms persist, call a physician. Take victim immediately to hospital.
Immediate Medical Attention
Take victim immediately to hospital.
Medical Treatment
The first aid procedure should be established in consultation with the doctor responsible for industrial medicine.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
High volume water jet
Do not allow run-off from fire fighting to enter drains or water courses.
Firefighter Protection
Wear self-contained breathing apparatus for firefighting if necessary.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protective equipment. Refer to protective measures listed in sections 7 and 8.
Prevent product from entering drains. Prevent further leakage or spillage if safe to do so. Local authorities should be advised if significant spillages cannot be contained.
Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust).
Materials: inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Do not breathe vapours/dust. Avoid exposure - obtain special instructions before use. Avoid contact with skin and eyes. For personal protection see section 8. Smoking, eating and drinking should be prohibited in the application area. Dispose of rinse water in accordance with local and national regulations.
Keep container tightly closed in a dry and well-ventilated place. Electrical installations / working materials must comply with the technological safety standards.
When using do not eat or drink. When using do not smoke. Wash hands before breaks and at the end of workday.
Normal measures for preventive fire protection.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No data available
In case of contact through splashing: Material: Nitrile rubber, Break through time: > 30 min, Glove thickness: > 0,11 mm. In case of full contact: Material: butyl-rubber, Break through time: > 480 min, Glove thickness: > 0,4 mm. Remarks: The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it.
Use eye protection according to EN 166. Eye wash bottle with pure water. Tightly fitting safety goggles.
In the case of vapour formation use a respirator with an approved filter.
Impervious clothing. Choose body protection according to the amount and concentration of the dangerous substance at the work place.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
No dangerous reaction known under conditions of normal use.
No decomposition if stored and applied as directed.
No data available
No data available
No data available
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Send to a licensed waste management company.
Do not contaminate ponds, waterways or ditches with chemical or used container. Send to a licensed waste management company. Can be disposed as waste water, when in compliance with local regulations.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Chemical Safety Assessments for all substances in this product are either Complete or Not applicable.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for HPV 18 mRNA Probe?
The signal word is danger.
What is the physical form of HPV 18 mRNA Probe?
HPV 18 mRNA Probe is a liquid with no data available color. It has no data available odor.
What is the solubility of HPV 18 mRNA Probe?
completely miscible
What is HPV 18 mRNA Probe used for?
Laboratory chemicals, Refer to product literature for further details.
What are the hazard statements for HPV 18 mRNA Probe?
This substance has 3 hazard statements:
- H351: Suspected of causing cancer.
- H360D: May damage the unborn child.
- H373: May cause damage to organs through prolonged or repeated exposure.
What is the melting point of HPV 18 mRNA Probe?
The melting point is No data available and the boiling point is No data available.