Chemical Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Uses Information
Overview
HPV 6 mRNA Probe commonly used laboratory chemicals, refer to product literature for further details..
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
Hazard Classifications
GHS Hazard Pictograms & Safety Symbols
GHS08
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
- H351: Suspected of causing cancer.
- H360D: May damage the unborn child.
- H373: May cause damage to organs through prolonged or repeated exposure.
Precautionary Statements
- P201: Obtain special instructions before use.
- P202: Do not handle until all safety precautions have been read and understood.
- P260: Do not breathe mist or vapours.
- P280: Wear protective gloves/ protective clothing/ eye protection/ face protection/ hearing protection.
- P308 + P313: IF exposed or concerned: Get medical advice/ attention.
- P501: Dispose of contents/ container to an approved waste disposal plant.
Chemical Manufacturers & Supply Chain
Authorized suppliers, manufacturers, and distribution network information
Roche Diagnostics Deutschland GmbH
national supplier
Sandhoferstrasse 116 68305 Mannheim Deutschland
DE
+496217590
+496217592890
24/7 Emergency Response & Poison Control
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
Central Works Security Roche Diagnostics GmbH
+49(0)621-759-2203
DE
Centre for detoxification: Mainz
+49(0)6131-19240
DE
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
mixtureChemical Components & Hazardous Substances
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| formamide EC: 200-842-0 | 75-12-7 | 30-50% | โ ๏ธ Hazardous |
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
๐ซ Inhalation Exposure
Move to fresh air. If unconscious, place in recovery position and seek medical advice. If symptoms persist, call a physician.
๐๏ธ Skin Contact
If on skin, rinse well with water.
๐๏ธ Eye Contact
Flush eyes with water as a precaution. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing. If eye irritation persists, consult a specialist.
๐ฝ๏ธ Ingestion/Swallowing
Keep respiratory tract clear. Never give anything by mouth to an unconscious person. If symptoms persist, call a physician. Take victim immediately to hospital.
๐จ Immediate Medical Attention Required
The first aid procedure should be established in consultation with the doctor responsible for industrial medicine.
Medical Treatment
The first aid procedure should be established in consultation with the doctor responsible for industrial medicine.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Exposure Controls & Personal Protective Equipment (PPE)
Occupational exposure limits, engineering controls, and required safety equipment
๐ญ Engineering Controls
No data available
๐งค Hand Protection
In case of contact through splashing: Material : Nitrile rubber Break through time : - 30 min Glove thickness : - 0,11 mm In case of full contact: Material : butyl-rubber Break through time : - 480 min Glove thickness : - 0,4 mm Remarks : The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it. This recommendation is only valid for the product mentioned in the safety data sheet and provided by us and for the application specified by us. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time. The suitability for a specific workplace should be discussed with the producers of the protective gloves.
๐๏ธ Eye Protection
Use eye protection according to EN 166. Eye wash bottle with pure water Tightly fitting safety goggles
๐ท Respiratory Protection
In the case of vapour formation use a respirator with an approved filter.
๐ฆบ Skin/Body Protection
Impervious clothing Choose body protection according to the amount and concentration of the dangerous substance at the work place.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for HPV 6 mRNA Probe?
The signal word for this substance is "danger".
What is the physical form of HPV 6 mRNA Probe?
HPV 6 mRNA Probe is a liquid with no data available color. It has no data available odor.
What is the solubility of HPV 6 mRNA Probe?
completely miscible
What is HPV 6 mRNA Probe used for?
Laboratory chemicals, Refer to product literature for further details.
What are the hazard statements for HPV 6 mRNA Probe?
This substance has 3 hazard statements: H351: Suspected of causing cancer. H360D: May damage the unborn child. H373: May cause damage to organs through prolonged or repeated exposure.
What is the melting point of HPV 6 mRNA Probe?
The melting point is No data available and the boiling point is No data available.