Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Entellan new rapid mounting medium for microscopy
- Product Code
- 1.07961
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
In vitro diagnostic reagent, Reagent for analysis
Manufacturers & Suppliers
Merck KGaA
manufacturer
Frankfurter Str. 250 D-64271 DARMSTADT
+49 (0)6151 72-0
Emergency Contacts
CHEMTREC (GB)
+(44)-870-8200418
CHEMTREC Ireland
+(353)-19014670
CHEMTREC India
001-803-017-9114
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS08
GHS07
Hazard Statements
Precautionary Statements
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Xyleen (mengsel) EC: 215-535-7 | 1330-20-7 | 50 - 70% | Yes |
| Acrylate Polymer | --- | 30 - 50% | No |
| METHYL METHACRYLATE EC: 201-297-1 | 80-62-6 | 0.1 - 1% | Yes |
| Butyl methacrylate EC: 202-615-1 | 97-88-1 | 0.1 - 1% | Yes |
For the full text of the H-Statements mentioned in this Section, see Section 16.
First Aid Measures
Emergency procedures for chemical exposure incidents
After inhalation: fresh air. Immediately call in physician. If breathing stops: immediately apply artificial respiration, if necessary also oxygen.
In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/ shower. Consult a physician.
After eye contact: rinse out with plenty of water. Call in ophthalmologist. Remove contact lenses.
After swallowing: caution if victim vomits. Keep airways free. Call a physician immediately.
Symptoms: Risk of aspiration! Pulmonary failure possible after aspiration of vomit.
Immediate Medical Attention
No data available
Medical Treatment
No data available
Related Substances
Similar chemicals with comparable safety profiles
Fluorescence Mounting Medium
---
Faramount Aqueous Mounting Medium
---
Dako Mounting Medium
---
Tissue-Tek Glas Mounting Medium
---
Neo-Clear (xylene substitute) for microscopy
CAS: 64741-65-7
3M Photomount (PL 9479)
---
VECTASHIELD Mounting Medium
---
Glutardialdehyde solution 25% for electron microscopy, acc. to P.J. Anderson (purified and filled under nitrogen)
---
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de). Splash contact: Material: Viton, Minimum layer thickness: 0,7 mm, Break through time: 480 min, Material tested: Vitoject (KCL 890 / Aldrich Z677698, Size M). Full contact: Material: Viton, Minimum layer thickness: 0,7 mm, Break through time: 480 min, Material tested: Vitoject (KCL 890 / Aldrich Z677698, Size M).
Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses
Recommended Filter type: Filter A (acc. to DIN 3181) for vapours of organic compounds. The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.
Flame retardant antistatic protective clothing.
Do not let product enter drains. Risk of explosion.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1307
- Shipping Name
- XYLENES, SOLUTION
- Transport Class
- 3
- Packing Group
- III
No data available
No data available
No data available
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Entellan new rapid mounting medium for microscopy?
The signal word is danger.
What is the physical form of Entellan new rapid mounting medium for microscopy?
Entellan new rapid mounting medium for microscopy is a liquid appearing as form: liquid color: colorless with colorless color. It has of xylene odor.
What is Entellan new rapid mounting medium for microscopy used for?
In vitro diagnostic reagent, Reagent for analysis
What are the hazard statements for Entellan new rapid mounting medium for microscopy?
This substance has 9 hazard statements:
- H226: Flammable liquid and vapor.
- H304: May be fatal if swallowed and enters airways.
- H312 + H332: Harmful in contact with skin or if inhaled.
- H315: Causes skin irritation.
- H317: May cause an allergic skin reaction.
- H319: Causes serious eye irritation.
- H335: May cause respiratory irritation.
- H373: May cause damage to organs (Central nervous system, Liver, Kidney) through prolonged or repeated exposure if inhaled.
- H412: Harmful to aquatic life with long lasting effects.
What is the melting point of Entellan new rapid mounting medium for microscopy?
The melting point is No data available and the boiling point is 137 - 143 C at 1.013 hPa.