NextSDS Logo
Safety Data Sheet EN

Neo-Mount® anhydrous mounting medium for microscopy

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Neo-Mount® anhydrous mounting medium for microscopy
Product Code
109016

Regulatory Identifiers

CAS Number
N/A
REACH No.
This product is a mixture. REACH Registration Number see section 3.

Identified Uses

In vitro diagnostic reagent, Reagent for analysis For additional information on uses please refer to the Merck Chemicals portal (www.merck-chemicals.com).

Manufacturers & Suppliers

M

Merck KGaA

manufacturer

64271 Darmstadt, Germany

+49 6151 72-0

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. Cat. 2 H225
STOT SE Cat. 3 H336

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

Hazard Statements

H225 Highly flammable liquid and vapour.
H336 May cause drowsiness or dizziness.

Precautionary Statements

P210 Keep away from heat/sparks/open flames/hot surfaces. - No smoking.
P240 Ground/bond container and receiving equipment.
P403 + P235 Store in a well-ventilated place. Keep cool.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
naphtha (petroleum) (143° bis 190°C) 64742-49-0 50 - 100% Yes
isobutyl methacrylate 97-86-9 0.25 - 1% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

After inhalation: fresh air. Consult doctor if feeling unwell.

Symptoms: Drowsiness, Headache, Dizziness, narcosis

Skin contact

After skin contact: wash off with plenty of water. Remove contaminated clothing.

Symptoms: Drying-out effect resulting in rough and chapped skin., Dermatitis

Eye contact

After eye contact: rinse out with plenty of water with the eyelid held wide open. Call in ophthalmologist if necessary.

Symptoms: irritant effects

Ingestion

After swallowing: immediately make victim drink water (two glasses at most). Consult a physician.

Immediate Medical Attention

Consult doctor if feeling unwell (inhalation), Call in ophthalmologist if necessary (eyes), Consult a physician (swallowing).

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Carbon dioxide (CO2), Foam, Dry powder

Unsuitable media

For this substance/mixture no limitations of extinguishing agents are given.

Specific hazards

Combustible. Pay attention to flashback. Vapours are heavier than air and may spread along floors. Forms explosive mixtures with air at ambient temperatures.

Instructions

Cool closed containers exposed to fire with water spray.

Firefighter Protection

Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid substance contact. Do not breathe vapours, aerosols. Evacuate the danger area, observe emergency procedures, consult an expert.

Environmental

Do not empty into drains. Risk of explosion.

Cleanup methods

Take up with liquid-absorbent material (e.g. Chemizorb®).

Materials: liquid-absorbent material (e.g. Chemizorb®)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Work under hood. Do not inhale substance/mixture. Avoid generation of vapours/aerosols. Observe label precautions.

Storage

Keep container tightly closed in a dry and well-ventilated place. Keep away from heat and sources of ignition. Store at +15°C to +25°C.

Hygiene

Change contaminated clothing. Preventive skin protection recommended. Wash hands after working with substance.

Fire prevention

Keep away from open flames, hot surfaces and sources of ignition. Take precautionary measures against static discharge.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Technical measures and appropriate working operations should be given priority over the use of personal protective equipment.

Hands

full contact: Glove material: Nitrile rubber, Glove thickness: 0,40 mm, Break through time: > 480 min; splash contact: Glove material: polychloroprene, Glove thickness: 0,65 mm, Break through time: > 30 min. The protective gloves to be used must comply with the specifications of EC Directive 89/686/EEC and the related standard EN374, for example KCL 730 Camatril® -Velours (full contact), KCL 720 Camapren® (splash contact).

Eyes

Safety glasses

Respiratory

required when vapours/aerosols are generated. Recommended Filter type: Filter A (acc. to DIN 3181) for vapours of organic compounds. The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer.

Skin/Body

Flame retardant antistatic protective clothing

Environmental

Do not empty into drains. Risk of explosion.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
viscous
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
colourless
Colour Intensity
---
Form
viscous
Odor
slightly petrol-like
Odor Threshold
No information available.
Ph
No information available.
Melting Point
No information available.
Boiling Point
No information available.
Flash Point
19,5 °C
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No information available.
Vapor Pressure
No information available.
Vapor Density
---
Relative Density
0,819 - 0,822 g/cm³ at 20 °C
Bulk Density
---
Density
---
Flammability
No information available.
Upper Explosive Limit
No information available.
Lower Explosive Limit
No information available.
Explosive Limits
---
Auto Ignition Temperature
No information available.
Decomposition Temperature
No information available.
Solubility
---
Partition Coefficient
No information available.
Solubility In Water
insoluble
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
250 - 350 mPa.s at 20 °C
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable under standard ambient conditions (room temperature).

Reactivity

Vapours may form explosive mixture with air.

Hazardous reactions

Violent reactions possible with: Strong oxidizing agents

Avoid

Warming.

Incompatible

no information available

Decomposition

no information available

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1268
Shipping Name
PETROLEUM DISTILLATES, N.O.S.
Transport Class
3
Packing Group
II
ADR

yes

IMDG

yes

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Neo-Mount® anhydrous mounting medium for microscopy?

The signal word is danger.

What is the physical form of Neo-Mount® anhydrous mounting medium for microscopy?

Neo-Mount® anhydrous mounting medium for microscopy is a viscous with colourless color. It has slightly petrol-like odor.

What is Neo-Mount® anhydrous mounting medium for microscopy used for?

In vitro diagnostic reagent, Reagent for analysis For additional information on uses please refer to the Merck Chemicals portal (www.merck-chemicals.com).

What are the hazard statements for Neo-Mount® anhydrous mounting medium for microscopy?

This substance has 2 hazard statements:

  • H225: Highly flammable liquid and vapour.
  • H336: May cause drowsiness or dizziness.

What is the melting point of Neo-Mount® anhydrous mounting medium for microscopy?

The melting point is No information available. and the boiling point is No information available..