NextSDS Logo
3-

3-HYDROXYPROPIONIC ACID 30% SOLUTION IN WATER

DANGER liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
3-HYDROXYPROPIONIC ACID 30% SOLUTION IN WATER
Product Code
792659

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Laboratory chemicals, Manufacture of substances

Overview

3-HYDROXYPROPIONIC ACID 30% SOLUTION IN WATER commonly used laboratory chemicals, manufacture of substances.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Acute Tox. Category 4 H302
Skin Irrit. Category 2 H315
Eye Dam. Category 1 H318
STOT SE Category 3 H335

GHS Hazard Pictograms & Safety Symbols

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS05 GHS Hazard Pictogram: Corrosive hazard - Materials that can cause severe skin burns and eye damage

GHS05

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H302: Harmful if swallowed.
  • H315: Causes skin irritation.
  • H318: Causes serious eye damage.
  • H335: May cause respiratory irritation.

Precautionary Statements

  • P280: Wear eye protection/ face protection.
  • P302+P352: IF ON SKIN: Wash with plenty of water.
  • P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes.
  • P310: Immediately call a POISON CENTER/ doctor.
  • IF SWALLOWED: Call a POISON CENTER/ doctor if you feel unwell. Rinse mouth.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Merck Life Science BV/SRL

manufacturer

๐Ÿ“

Brusselsesteenweg 288 B-3090 OVERIJSE

๐ŸŒ

BE

๐Ÿ“ž

+32 (0)3 899-1301

๐Ÿ“ 

+32 (0)3 899-1311

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

CHEMTREC

๐Ÿ“ž

+(32) 28 083237

๐ŸŒ

BE

Anti-poison centre

๐Ÿ“ž

070 245245

๐ŸŒ

BE

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
3-hydroxypropionic acid
EC: 207-974-8
503-66-2 30-50% โš ๏ธ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.

๐Ÿ–๏ธ Skin Contact

Wash off with soap and plenty of water. Consult a physician.

๐Ÿ‘๏ธ Eye Contact

Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.

๐Ÿฝ๏ธ Ingestion/Swallowing

Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.

๐Ÿšจ Immediate Medical Attention Required

No data available

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Not available
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
liquid
๐Ÿ‘ƒ Odor
Not available
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
Not available
๐ŸงŠ Melting Point
Not available
๐Ÿ’จ Boiling Point
Not available
๐Ÿ”ฅ Flash Point
- 110 C
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
Not available
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
1,066 g/cm3 at 25 C
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not available
๐Ÿ”ฅ Flammability
Not available
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Lower Explosive Limit
Not available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Not available
๐Ÿ“Š Decomposition Temperature
Not available
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not available
๐Ÿ“Š Solubility In Water
Not available
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday.

๐Ÿงค Hand Protection

Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it.

๐Ÿ‘๏ธ Eye Protection

Tightly fitting safety goggles. Faceshield (8-inch minimum). Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).

๐Ÿ˜ท Respiratory Protection

Where risk assessment shows air-purifying respirators are appropriate use a fullface respirator with multi-purpose combination (US) or type ABEK (EN 14387) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).

๐Ÿฆบ Skin/Body Protection

Complete suit protecting against chemicals, The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.

๐ŸŒ Environmental Exposure Controls

Do not let product enter drains.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿ“ฆ Proper Shipping Name

Not dangerous goods

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for 3-HYDROXYPROPIONIC ACID 30% SOLUTION IN WATER?

The signal word for this substance is "danger".

What is the physical form of 3-HYDROXYPROPIONIC ACID 30% SOLUTION IN WATER?

3-HYDROXYPROPIONIC ACID 30% SOLUTION IN WATER is a liquid .

What is 3-HYDROXYPROPIONIC ACID 30% SOLUTION IN WATER used for?

Laboratory chemicals, Manufacture of substances

What are the hazard statements for 3-HYDROXYPROPIONIC ACID 30% SOLUTION IN WATER?

This substance has 4 hazard statements: H302: Harmful if swallowed. H315: Causes skin irritation. H318: Causes serious eye damage. H335: May cause respiratory irritation.