Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Codeine 6-beta-D-Glucuronide 0.1 mg/ml in Water
Product Code
LGCAMP0004.20-34

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Reference material for laboratory use only

Uses advised against

No further relevant information available.

Manufacturers & Suppliers

LGC Limited logo

LGC Limited

manufacturer

Queens Road, Teddington, Middlesex TW11 0LY, UNITED KINGDOM

http://www.lgcstandards.com

Emergency Contacts

Emergency Contact

+44 (0) 20 8943 7000

Monday - Friday : 8am - 5pm

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mixture: consisting of the following components.

Chemical Name CAS Number Concentration Hazardous
Codeine-6-β-D-glucuronide 20736-11-2 0.1% Yes

For the wording of the listed risk phrases refer to section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of complaints.

Skin contact

Immediately wash with water and soap and rinse thoroughly.

Eye contact

Rinse opened eye for several minutes under running water.

Ingestion

Rinse mouth. Do not induce vomiting.

Medical Treatment

No further relevant information available.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.

Specific hazards

Formation of toxic gases is possible during heating or in case of fire.

Firefighter Protection

Wear self-contained respiratory protective device.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Dilute with plenty of water.

Cleanup methods

Absorb with liquid-binding material

Materials: sand, diatomite, acid binders, universal binders, sawdust

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Store in cool, dry place in tightly closed receptacles.

Storage

Store in a cool location. Please refer to the manufacturer's certificate for specific storage and transport temperature conditions. Keep container in a well-ventilated place.

Fire prevention

No special measures required. Keep away from sources of ignition and heat.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No further data; see item 7.

Hands

The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. The protective gloves to be used must comply with the specifications of EC Directive 89/686/EEC and the related standard EN374. Material of gloves: Nitrile rubber, NBR. Penetration time of glove material: The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eyes

Safety glasses

Respiratory

Not required.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Colourless liquid
Colour
Colourless
Colour Intensity
---
Form
Liquid
Odor
Odourless
Odor Threshold
Not determined.
Ph
Not determined.
Melting Point
Not determined.
Boiling Point
100 °C
Flash Point
Not applicable.
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not determined.
Vapor Pressure
23 hPa
Vapor Density
Not determined.
Relative Density
Not determined.
Bulk Density
---
Density
Not determined.
Flammability
Not determined.
Upper Explosive Limit
Not determined.
Lower Explosive Limit
Not determined.
Explosive Limits
---
Auto Ignition Temperature
Not determined.
Decomposition Temperature
Not determined.
Solubility
---
Partition Coefficient
Not determined.
Solubility In Water
Fully miscible.
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
Not determined.
Kinematic Viscosity
Not determined.
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

Stable under normal conditions.

Hazardous reactions

No dangerous reactions known.

Avoid

Heat.

Incompatible

Strong oxidizing agents.

Decomposition

Formation of toxic gases is possible during heating or in case of fire.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Must not be disposed of together with household garbage.

Waste Codes

Not specified Waste disposal key numbers from EWC have to be assigned depending on origin and processing. EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
Not applicable
Transport Class
Not applicable
Packing Group
Not applicable
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Codeine 6-beta-D-Glucuronide 0.1 mg/ml in Water?

The signal word is no signal word.

What is the physical form of Codeine 6-beta-D-Glucuronide 0.1 mg/ml in Water?

Codeine 6-beta-D-Glucuronide 0.1 mg/ml in Water is a liquid appearing as colourless liquid with colourless color. It has odourless odor.

What is Codeine 6-beta-D-Glucuronide 0.1 mg/ml in Water used for?

Reference material for laboratory use only

What is the melting point of Codeine 6-beta-D-Glucuronide 0.1 mg/ml in Water?

The melting point is Not determined. and the boiling point is 100 °C.