NextSDS Logo
GR

GRF GASLEAKDETECTOR AE 400ML*12 L313

WARNING Aerosol SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
GRF GASLEAKDETECTOR AE 400ML*12 L313
Product Code
L313

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Metal-working product

Overview

GRF GASLEAKDETECTOR AE 400ML*12 L313 is a form: aerosol substance commonly used metal-working product.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Warning)

Hazard Classifications

Aerosol Category 3 H229

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H229: Pressurised container: May burst if heated.

Precautionary Statements

  • P101: If medical advice is needed, have product container or label at hand.
  • P102: Keep out of reach of children.
  • P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
  • P251: Do not pierce or burn, even after use.
  • P410 + P412: Protect from sunlight. Do not expose to temperatures exceeding 50 C/122 F.
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Bison International

manufacturer

Dr.A.F.Philipsstraat 9 NL-4462 EW Goes PO Box 160 NL-4460 AD Goes

NL

+31 88 3235800

PSRA

undefined

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Bison and Griffon products

+31 88 3235700

NL

mo-fr 08:00h-17:00h (CET)

UHU products

+ 49 (0) 30/19240

DE

mo-fr 08:00h-17:00h (CET)

(Notruf)

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Metal working product

Additional Information

For the wording of the listed hazard phrases refer to section 16.

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Supply fresh air; consult doctor in case of complaints. No special measures required.

Eye Contact

Rinse opened eye for several minutes under running water.

Ingestion/Swallowing

If symptoms persist consult doctor.

Immediate Medical Attention Required

No further relevant information available.

Medical Treatment

No further relevant information available.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Solidification Point
Not available
Molecular Weight
18.02 g/mol
Vapor Pressure
23 hPa Vapour pressure at 50 C: 123 hPa
Kinematic Viscosity
Not determined.
Solubility
water: Not miscible or difficult to mix.
Odor Threshold
Not determined.
Appearance
Form: Aerosol
Flash Point
Not applicable, as aerosol.
Critical Property
Freezing Point
0 C
Melting Point
0 C
Critical Property
Metal Corrosion
Void
Colour
According to product specification
Upper Explosive Limit
12.6 Vol %
State Under Standard Conditions
Not available
Colour Intensity
Not available
Solubility In Fat
Not available
Auto Ignition Temperature
Product is not selfigniting.
Vapor Density
Not determined.
Bulk Density
Not available
Density
1.04 g/cm
Critical Property
Form
Aerosol
Physical State
Aerosol
Critical Property
Relative Density
Not determined.
Lower Explosive Limit
2.6 Vol %
Crystallisation Point
Not available
Relative Evaporation Rate
Not available
Cloud Point
Not available
Boiling Point
100 C
Critical Property
Softening Point
Not available
Explosive Limits
Not available
Dynamic Viscosity
0.952 mPas
Flammability
Not applicable.
Odor
Characteristic
Ph
Not determined.
Evaporation Rate
Not applicable.
Physical State Data
aerosol
Decomposition Temperature
Not determined.
Solubility In Water
Not miscible or difficult to mix.
Partition Coefficient
Not determined.
Properties Status
Not available
Voc Content
0.40 %
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

No further data; see section 7.

Hand Protection

The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation Recommended thickness of the material: > 0,12 mm Nitrile rubber, NBR For the mixture of chemicals mentioned below the penetration time has to be at least 10 minutes (Permeation according to EN 374 Part 3: Level 1).

Eye Protection

Not required.

Respiratory Protection

Not required.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

UN1950

Proper Shipping Name

AEROSOLS

Packing Group

not regulated

ADR Transport Precautions

Warning: Gases.

IMDG Maritime Transport Precautions

Warning: Gases.

IATA Air Transport Precautions

Warning: Gases.

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for GRF GASLEAKDETECTOR AE 400ML*12 L313?

The signal word for this substance is "warning".

What is the physical form of GRF GASLEAKDETECTOR AE 400ML*12 L313?

GRF GASLEAKDETECTOR AE 400ML*12 L313 is a aerosol appearing as form: aerosol with according to product specification color. It has characteristic odor.

What is the solubility of GRF GASLEAKDETECTOR AE 400ML*12 L313?

water: Not miscible or difficult to mix.

What is GRF GASLEAKDETECTOR AE 400ML*12 L313 used for?

Metal-working product

What are the hazard statements for GRF GASLEAKDETECTOR AE 400ML*12 L313?

This substance has 1 hazard statements: H229: Pressurised container: May burst if heated.

What is the melting point of GRF GASLEAKDETECTOR AE 400ML*12 L313?

The melting point is 0 C and the boiling point is 100 C.