NextSDS Logo
Safety Data Sheet EN

GRF GASLEAKDETECTOR AE 400ML*12 L313

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
GRF GASLEAKDETECTOR AE 400ML*12 L313

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Metal-working product

Uses advised against

No further relevant information available.

Manufacturers & Suppliers

B

Bison International

manufacturer

Dr.A.F.Philipsstraat 9, NL-4462 EW Goes, PO Box 160, NL-4460 AD Goes

+31 88 3235700

Emergency Contacts

Bison and Griffon products

+31 88 3235700

mo-fr 08:00h-17:00h (CET)

UHU products

+ 49 (0) 30/19240

mo-fr 08:00h-17:00h (CET)

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Aerosol Cat. 3 H229

GHS Pictograms

GHS02 - Flammable

GHS02

Hazard Statements

H229 Pressurised container: May burst if heated.

Precautionary Statements

P101 If medical advice is needed, have product container or label at hand.
P102 Keep out of reach of children.
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P251 Do not pierce or burn, even after use.
P410 + P412 Protect from sunlight. Do not expose to temperatures exceeding 50 °C/122 °F.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Metal working product

For the wording of the listed hazard phrases refer to section 16.

Notes

Dangerous components: Void

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of complaints. No special measures required.

Eye contact

Rinse opened eye for several minutes under running water.

Ingestion

If symptoms persist consult doctor.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use fire extinguishing methods suitable to surrounding conditions.

Specific hazards

No further relevant information available.

Firefighter Protection

No special measures required.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Not required.

Environmental

No special measures required.

Cleanup methods

Absorb liquid components with liquid-binding material.

Materials: liquid-binding material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

No special precautions are necessary if used correctly.

Storage

Observe official regulations on storing packagings with pressurised containers.

Fire prevention

No special measures required.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No further data; see section 7.

Hands

The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: Nitrile rubber, NBR. Recommended thickness of the material: > 0,12 mm. Penetration time of glove material: For the mixture of chemicals mentioned below the penetration time has to be at least 10 minutes (Permeation according to EN 374 Part 3: Level 1).

Eyes

Not required.

Respiratory

Not required.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Explosive Limits
---
Lower Explosive Limit
2.6 Vol %
Partition Coefficient
Not determined.
Voc Content
0.40 %
Decomposition Temperature
Not determined.
Crystallisation Point
---
Cloud Point
---
Evaporation Rate
Not applicable.
State Under Standard Conditions
---
Physical State Data
aerosol
Kinematic Viscosity
Not determined.
Appearance
Form: Aerosol
Physical State
Aerosol
Relative Density
Not determined.
Molecular Weight
18.02 g/mol
Solubility In Water
Not miscible or difficult to mix.
Odor
Characteristic
Softening Point
---
Properties Status
---
Odor Threshold
Not determined.
Colour Intensity
---
Form
Aerosol
Ph
Not determined.
Flash Point
Not applicable, as aerosol.
Density
1.04 g/cm³
Auto Ignition Temperature
Product is not selfigniting.
Colour
According to product specification
Vapor Pressure
23 hPa (at 20 °C), 123 hPa (at 50 °C)
Vapor Density
Not determined.
Melting Point
0 °C
Metal Corrosion
Void
Solubility In Fat
---
Freezing Point
0 °C
Bulk Density
---
Solubility
water: Not miscible or difficult to mix.
Solidification Point
---
Boiling Point
100 °C
Flammability
Not applicable.
Relative Evaporation Rate
---
Upper Explosive Limit
12.6 Vol %
Dynamic Viscosity
0.952 mPas
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Reactivity

No further relevant information available.

Hazardous reactions

No dangerous reactions known.

Avoid

No further relevant information available.

Incompatible

No further relevant information available.

Decomposition

No dangerous decomposition products known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Must not be disposed together with household garbage. Do not allow product to reach sewage system. Disposal must be made according to official regulations.

Disposal

Must not be disposed together with household garbage. Do not allow product to reach sewage system.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1950
Shipping Name
AEROSOLS
Transport Class
2
Packing Group
not regulated
ADR

Warning: Gases.

IMDG

Warning: Gases. SW1 Protected from sources of heat. SW22 For AEROSOLS with a maximum capacity of 1 litre: Category A. For AEROSOLS with a capacity above 1 litre: Category B. For WASTE AEROSOLS: Category C, Clear of living quarters. SG69 For AEROSOLS with a maximum capacity of 1 litre: Segregation as for class 9. Stow 'separated from' class 1 except for division 1.4. For AEROSOLS with a capacity above 1 litre: Segregation as for the appropriate subdivision of class 2. For WASTE AEROSOLS: Segregation as for the appropriate subdivision of class 2.

IATA

Warning: Gases.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for GRF GASLEAKDETECTOR AE 400ML*12 L313?

The signal word is warning.

What is the physical form of GRF GASLEAKDETECTOR AE 400ML*12 L313?

GRF GASLEAKDETECTOR AE 400ML*12 L313 is a aerosol appearing as form: aerosol with according to product specification color. It has characteristic odor.

What is the solubility of GRF GASLEAKDETECTOR AE 400ML*12 L313?

water: Not miscible or difficult to mix.

What is GRF GASLEAKDETECTOR AE 400ML*12 L313 used for?

Metal-working product

What are the hazard statements for GRF GASLEAKDETECTOR AE 400ML*12 L313?

This substance has 1 hazard statement:

  • H229: Pressurised container: May burst if heated.

What is the melting point of GRF GASLEAKDETECTOR AE 400ML*12 L313?

The melting point is 0 °C and the boiling point is 100 °C.