Chemical Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Uses Information
Overview
MOLYKOTE(R) P-37 ANTISEIZE PASTE .
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
Hazard Classifications
GHS Hazard Pictograms & Safety Symbols
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
Precautionary Statements
Chemical Manufacturers & Supply Chain
Authorized suppliers, manufacturers, and distribution network information
Dow Corning Silicone Trading (Shanghai) Co., Ltd.
manufacturer
No.268, De Lin Road, WaiGaoQiao Free Trade Zone, Shanghai 200131, China
CN
(86 21)37747110
(86 21) 57741162
24/7 Emergency Response & Poison Control
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
Dow Corning Silicone Trading (Shanghai) Co., Ltd.
(86 21) 37741000
CN
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
MixtureChemical Components & Hazardous Substances
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| calcium hydroxide EC: 215-137-3 | 1305-62-0 | 10-30% | โ ๏ธ Hazardous |
Composition Notes
*According to European Commission Directive 1999/45/EC (Article 3 [3])
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
๐ซ Inhalation Exposure
No first aid should be needed.
๐๏ธ Skin Contact
No first aid should be needed.
๐๏ธ Eye Contact
Immediately flush with water for 15 minutes.
๐ฝ๏ธ Ingestion/Swallowing
Get medical attention.
๐จ Immediate Medical Attention Required
Get medical attention.
Medical Treatment
Treat according to person's condition and specifics of exposure. Treat symptomatically.
Fire Fighting Measures & Emergency Response
Fire suppression methods, extinguishing media, and firefighting safety procedures
โ Suitable Extinguishing Media
On large fires use dry chemical, foam or water spray. On small fires use carbon dioxide (CO2), dry chemical or water spray. Water can be used to cool fire exposed containers.
โ Unsuitable Extinguishing Media
None established.
โ ๏ธ Specific Fire Hazards
None.
๐ฅ Fire Fighting Instructions
Determine the need to evacuate or isolate the area according to your local emergency plan. Use water spray to keep fire exposed containers cool.
๐ก๏ธ Firefighter Protection Equipment
Self-contained breathing apparatus and protective clothing should be worn in fighting large fires involving chemicals.
Accidental Release Measures & Spill Response
Emergency spill cleanup procedures, containment methods, and environmental protection
๐ Environmental Precautions
Do not allow large quantities to enter drains or surface waters.
๐งน Cleanup Methods
Wipe up or scrape up and contain for salvage or disposal.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Safe Handling & Storage Procedures
Industrial handling precautions, storage conditions, and workplace safety requirements
โ ๏ธ Handling Precautions
โข Use with adequate ventilation.
โข Avoid skin and eye contact.
โข Do not take internally.
๐ช Storage Conditions
โข Use reasonable care and store away from oxidizing materials.
๐งผ General Hygiene Measures
Exercise good industrial hygiene practice. Wash after handling, especially before eating, drinking or smoking.
Exposure Controls & Personal Protective Equipment (PPE)
Occupational exposure limits, engineering controls, and required safety equipment
๐ญ Engineering Controls
Local Ventilation: None should be needed. General Ventilation: Recommended. If this product is heated to > 150 degrees C, trace quantities of formaldehyde may be released, and adequate ventilation is required.
๐งค Hand Protection
No special protection needed.
๐๏ธ Eye Protection
Use proper protection - safety glasses as a minimum.
๐ท Respiratory Protection
No respiratory protection should be needed.
๐ฆบ Skin/Body Protection
Washing at mealtime and end of shift is adequate.
Chemical Stability & Reactivity Data
Chemical stability, hazardous reactions, and incompatible materials information
โ Chemical Stability
Stable.
โ ๏ธ Hazardous Reactions
Hazardous polymerization will not occur.
๐ซ Conditions to Avoid
None.
๐งช Incompatible Materials
Can react with strong oxidising agents.
๐จ Hazardous Decomposition Products
Carbon oxides and traces of incompletely burned carbon compounds. Metal oxides. Silicon dioxide. Formaldehyde.
Waste Disposal & Treatment Methods
Waste disposal procedures, treatment methods, and regulatory compliance requirements
๐๏ธ Product Disposal Recommendations
Dispose of in accordance with local regulations.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for MOLYKOTE(R) P-37 ANTISEIZE PASTE?
The signal word for this substance is "no signal word".
What is the physical form of MOLYKOTE(R) P-37 ANTISEIZE PASTE?
MOLYKOTE(R) P-37 ANTISEIZE PASTE is a paste with gray color. It has odorless odor.
What is the melting point of MOLYKOTE(R) P-37 ANTISEIZE PASTE?
The melting point is Not determined. and the boiling point is Not determined..