NextSDS Logo
Safety Data Sheet EN

MOLYKOTE(R) P-37 ANTISEIZE PASTE

How compliant is your chemical safety?

Free 2-minute compliance assessment

Check Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
MOLYKOTE(R) P-37 ANTISEIZE PASTE
Product Code
02322374

Regulatory Identifiers

CAS Number
N/A

Manufacturers & Suppliers

D

Dow Corning Silicone Trading (Shanghai) Co., Ltd.

manufacturer

No.268, De Lin Road, WaiGaoQiao Free Trade Zone, Shanghai 200131, China

(86 21)37747110

Emergency Contacts

Dow Corning Silicone Trading (Shanghai) Co., Ltd.

(86 21) 37741000

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type Mixture
Chemical Name CAS Number Concentration Hazardous
calcium hydroxide EC: 215-137-3 1305-62-0 10 - 30% Yes

Notes

*According to European Commission Directive 1999/45/EC (Article 3 [3])

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

No first aid should be needed.

Skin contact

No first aid should be needed.

Eye contact

Immediately flush with water for 15 minutes.

Ingestion

Get medical attention.

Immediate Medical Attention

Get medical attention.

Medical Treatment

Treat according to person's condition and specifics of exposure. Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

On large fires use dry chemical, foam or water spray. On small fires use carbon dioxide (CO2), dry chemical or water spray. Water can be used to cool fire exposed containers.

Unsuitable media

None established.

Specific hazards

None.

Instructions

Determine the need to evacuate or isolate the area according to your local emergency plan. Use water spray to keep fire exposed containers cool.

Firefighter Protection

Self-contained breathing apparatus and protective clothing should be worn in fighting large fires involving chemicals.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Do not allow large quantities to enter drains or surface waters.

Cleanup methods

Wipe up or scrape up and contain for salvage or disposal.

Related Substances

Similar chemicals with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Use with adequate ventilation. Avoid skin and eye contact. Do not take internally.

Storage

Use reasonable care and store away from oxidizing materials.

Hygiene

Exercise good industrial hygiene practice. Wash after handling, especially before eating, drinking or smoking.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Local Ventilation: None should be needed. General Ventilation: Recommended. If this product is heated to > 150 degrees C, trace quantities of formaldehyde may be released, and adequate ventilation is required.

Hands

No special protection needed.

Eyes

Use proper protection - safety glasses as a minimum.

Respiratory

No respiratory protection should be needed.

Skin/Body

Washing at mealtime and end of shift is adequate.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Paste
Physical State Data
solid
State Under Standard Conditions
---
Appearance
---
Colour
Gray
Colour Intensity
---
Form
Paste
Odor
Odorless
Odor Threshold
---
Ph
Not determined.
Melting Point
Not determined.
Boiling Point
Not determined.
Flash Point
Not applicable.
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
Not determined.
Vapor Density
Not determined.
Relative Density
1.21
Bulk Density
---
Density
---
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
Not determined.
Decomposition Temperature
---
Solubility
---
Partition Coefficient
Not determined.
Solubility In Water
0 g/l
Solubility In Fat
---
Molecular Weight
Not determined.
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable.

Hazardous reactions

Hazardous polymerization will not occur.

Avoid

None.

Incompatible

Can react with strong oxidising agents.

Decomposition

Carbon oxides and traces of incompletely burned carbon compounds. Metal oxides. Silicon dioxide. Formaldehyde.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Dispose of in accordance with local regulations.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for MOLYKOTE(R) P-37 ANTISEIZE PASTE?

The signal word is no signal word.

What is the physical form of MOLYKOTE(R) P-37 ANTISEIZE PASTE?

MOLYKOTE(R) P-37 ANTISEIZE PASTE is a paste with gray color. It has odorless odor.

What is the melting point of MOLYKOTE(R) P-37 ANTISEIZE PASTE?

The melting point is Not determined. and the boiling point is Not determined..