NextSDS Logo
IR

IRM 902

NO SIGNAL WORD Liquid. [Viscous liquid.] SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
IRM 902
Product Form
Liquid.
Product Code
2905-00

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Petrochemical industry: Petroleum refining. Naphthenic Lubricant.
Uses Advised Against
Not available.

Overview

IRM 902 commonly used petrochemical industry: petroleum refining. naphthenic lubricant..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word (No signal word)

Hazard Classifications

Not Classified

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Calumet Specialty Products Partners, L.P.

undefined

๐Ÿ“

2780 Waterfront Pkwy E. Dr. Suite 200 Indianapolis, Indiana 46214 USA

๐ŸŒ

US

๐Ÿ“ž

317-328-5660

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

CHEMTREC

๐Ÿ“ž

1-800-424-9300

๐ŸŒ

US

๐Ÿ•’

24hr.

CHEMTREC

๐Ÿ“ž

1-703-527-3887

๐ŸŒ

US

๐Ÿ•’

24hr.

๐Ÿ’ก

International

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Substance

General Composition

Distillates (petroleum), hydrotreated heavy naphthenic

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
SEVERELY HYDROTREATED NAPHTHENIC OIL
EC: 265-155-0
64742-52-5 100% โœ“ Non-hazardous

Additional Information

There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment and hence require reporting in this section.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Remove victim to fresh air and keep at rest in a position comfortable for breathing. Get medical attention if symptoms occur.

Symptoms:

No known significant effects or critical hazards.

๐Ÿ–๏ธ Skin Contact

Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Get medical attention if symptoms occur.

Symptoms:

No known significant effects or critical hazards.

๐Ÿ‘๏ธ Eye Contact

Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Get medical attention if irritation occurs.

Symptoms:

No known significant effects or critical hazards.

๐Ÿฝ๏ธ Ingestion/Swallowing

Wash out mouth with water. Remove victim to fresh air and keep at rest in a position comfortable for breathing. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Get medical attention if symptoms occur.

Symptoms:

No known significant effects or critical hazards.

๐Ÿšจ Immediate Medical Attention Required

Contact poison treatment specialist immediately if large quantities have been ingested or inhaled.

Medical Treatment

Treat symptomatically. No specific treatment.

Fire Fighting Measures & Emergency Response

Fire suppression methods, extinguishing media, and firefighting safety procedures

โœ… Suitable Extinguishing Media

Use an extinguishing agent suitable for the surrounding fire.

โŒ Unsuitable Extinguishing Media

Do not use water jet.

โš ๏ธ Specific Fire Hazards

In a fire or if heated, a pressure increase will occur and the container may burst.

๐Ÿ”ฅ Fire Fighting Instructions

Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training.

๐Ÿ›ก๏ธ Firefighter Protection Equipment

Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode.

Accidental Release Measures & Spill Response

Emergency spill cleanup procedures, containment methods, and environmental protection

๐Ÿšจ Emergency Procedures

No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Put on appropriate personal protective equipment.

๐Ÿ’ง Small Spill Procedures

Stop leak if without risk. Move containers from spill area. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.

๐ŸŒŠ Large Spill Procedures

Stop leak if without risk. Move containers from spill area. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations (see Section 13). Dispose of via a licensed waste disposal contractor. Note: see Section 1 for emergency contact information and Section 13 for waste disposal.

๐ŸŒ Environmental Precautions

Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers. Inform the relevant authorities if the product has caused environmental pollution (sewers, waterways, soil or air).

๐Ÿงน Cleanup Methods

Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material.

Cleanup Materials:

inert dry material; non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Liquid. [Viscous liquid.]
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Colorless to light yellow.
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Hydrocarbon.
๐Ÿ“Š Odor Threshold
Not available.
๐Ÿงช Ph
Not available.
๐ŸงŠ Melting Point
0C (32F)
Critical Property
๐Ÿ’จ Boiling Point
207 to 750C (404.6 to 1382F)
Critical Property
๐Ÿ”ฅ Flash Point
Open cup: 237C (458.6F)
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available.
๐Ÿ’จ Vapor Pressure
<0.011 kPa (<0.08 mm Hg) [room temperature]
๐Ÿ“Š Vapor Density
Not available.
๐Ÿ“Š Relative Density
0.934
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not available
๐Ÿ”ฅ Flammability
Not available.
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Lower Explosive Limit
Not available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Not available.
๐Ÿ“Š Decomposition Temperature
Not available.
๐Ÿ’ง Solubility
Insoluble in the following materials: cold water and hot water.
๐Ÿ“Š Partition Coefficient
>6
๐Ÿ“Š Solubility In Water
Not available
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Kinematic (40C (104F)): >0.21 cmยฒ/s (>21 cSt)
๐Ÿ“Š Properties Status
Not available

Safe Handling & Storage Procedures

Industrial handling precautions, storage conditions, and workplace safety requirements

โš ๏ธ Handling Precautions

โ€ข Put on appropriate personal protective equipment (see Section 8).

๐Ÿช Storage Conditions

โ€ข Store in accordance with local regulations.

โ€ข Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink.

โ€ข Keep container tightly closed and sealed until ready for use.

โ€ข Containers that have been opened must be carefully resealed and kept upright to prevent leakage.

โ€ข Do not store in unlabeled containers.

โ€ข Use appropriate containment to avoid environmental contamination.

๐Ÿงผ General Hygiene Measures

Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas. See also Section 8 for additional information on hygiene measures.

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Good general ventilation should be sufficient to control worker exposure to airborne contaminants.

๐Ÿงค Hand Protection

Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary.

๐Ÿ‘๏ธ Eye Protection

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: safety glasses with side-shields.

๐Ÿ˜ท Respiratory Protection

Use a properly fitted, air-purifying or air-fed respirator complying with an approved standard if a risk assessment indicates this is necessary. Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator.

๐Ÿฆบ Skin/Body Protection

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

๐ŸŒ Environmental Exposure Controls

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

โœ… Chemical Stability

The product is stable.

โš—๏ธ Reactivity

No specific test data related to reactivity available for this product or its ingredients.

โš ๏ธ Hazardous Reactions

Under normal conditions of storage and use, hazardous reactions will not occur.

๐Ÿšซ Conditions to Avoid

No specific data.

๐Ÿงช Incompatible Materials

No specific data.

๐Ÿ’จ Hazardous Decomposition Products

Under normal conditions of storage and use, hazardous decomposition products should not be produced.

Ecological Information & Environmental Impact

Environmental toxicity, biodegradation, bioaccumulation, and ecological effects data

๐ŸŒฑ Toxicity

Toxicity Product/ingredient name Result Species Exposure Distillates (petroleum), hydrotreated heavy naphthenic Acute EC50 >100 mg/l Algae 72 hours Acute EC50 >100 mg/l Crustaceans 48 hours Acute LC50 >100 mg/l Fish 96 hours

๐ŸŒฑ Persistence and degradability

Persistence and degradability Product/ingredient name Aquatic half-life Photolysis Biodegradability Distillates (petroleum), hydrotreated heavy naphthenic - - Inherent

๐ŸŒฑ Bioaccumulative potential

Bioaccumulative potential Product/ingredient name Distillates (petroleum), hydrotreated heavy naphthenic LogPow BCF Potential >6 - high

๐ŸŒฑ Mobility in soil

Mobility in soil Soil/water partition : Not available. coefficient (KOC)

๐ŸŒฑ Other adverse effects

Other adverse effects : No known significant effects or critical hazards.
No known significant effects or critical hazards.

Waste Disposal & Treatment Methods

Waste disposal procedures, treatment methods, and regulatory compliance requirements

โ™ป๏ธ Waste Treatment Methods

Dispose of surplus and non-recyclable products via a licensed waste disposal contractor. Waste should not be disposed of untreated to the sewer unless fully compliant with the requirements of all authorities with jurisdiction.

๐Ÿ—‚๏ธ Product Disposal Recommendations

Dispose of surplus and non-recyclable products via a licensed waste disposal contractor.

๐Ÿท๏ธ Waste Classification Codes

Not Regulated Not Regulated RCRA

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

Not regulated.

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for IRM 902?

The signal word for this substance is "no signal word".

What is the physical form of IRM 902?

IRM 902 is a liquid. [viscous liquid.] with colorless to light yellow. color. It has hydrocarbon. odor.

What is the solubility of IRM 902?

Insoluble in the following materials: cold water and hot water.

What is IRM 902 used for?

Petrochemical industry: Petroleum refining. Naphthenic Lubricant.

What is the melting point of IRM 902?

The melting point is 0C (32F) and the boiling point is 207 to 750C (404.6 to 1382F).