NextSDS Logo
Safety Data Sheet EN

IRM 902

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
IRM 902
Product Form
Liquid.
Product Code
2905-00
Chemical Name
Distillates (petroleum), hydrotreated heavy naphthenic
Synonyms
Baseoil - unspecified; Hydrotreated heavy naphthenic distillate solvent extract (petroleum); Distillates, petroleum, hydrotreated heavy naphthenic; Hydrotreated heavy naphthenic distillate, solvent extract, petroleum; Mineral oil, petroleum distillates, hydrotreated heavy naphthenic; Mineral oil, petroleum distillates, hydrotreated (severe) heavy naphthenic; Distillates (petroleum), hydro-treated heavy naphthenic; Base oil — unspecified

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Petrochemical industry: Petroleum refining. Naphthenic Lubricant.

Uses advised against

Not available.

Manufacturers & Suppliers

C

Calumet Specialty Products Partners, L.P.

manufacturer

2780 Waterfront Pkwy E. Dr., Suite 200, Indianapolis, Indiana 46214 USA

317-328-5660

Emergency Contacts

CHEMTREC

1-800-424-9300

24hr.

CHEMTREC

1-703-527-3887

24hr.

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Hazard Statements

No known significant effects or critical hazards.

Precautionary Statements

Not applicable.
Not applicable.
Not applicable.
Not applicable.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

Distillates (petroleum), hydrotreated heavy naphthenic 100%

Chemical Name CAS Number Concentration Hazardous
Distillates (petroleum), hydrotreated heavy naphthenic 64742-52-5 100% No

Occupational exposure limits, if available, are listed in Section 8.

Notes

Any concentration shown as a range is to protect confidentiality or is due to batch variation.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim to fresh air and keep at rest in a position comfortable for breathing. Get medical attention if symptoms occur.

Symptoms: No known significant effects or critical hazards.

Skin contact

Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Get medical attention if symptoms occur.

Symptoms: No known significant effects or critical hazards.

Eye contact

Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Get medical attention if irritation occurs.

Symptoms: No known significant effects or critical hazards.

Ingestion

Wash out mouth with water. Remove victim to fresh air and keep at rest in a position comfortable for breathing. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Do not induce vomiting unless directed to do so by medical personnel. Get medical attention if symptoms occur.

Symptoms: No known significant effects or critical hazards.

Immediate Medical Attention

Contact poison treatment specialist immediately if large quantities have been ingested or inhaled.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use an extinguishing agent suitable for the surrounding fire.

Unsuitable media

Do not use water jet.

Specific hazards

In a fire or if heated, a pressure increase will occur and the container may burst.

Instructions

Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training.

Firefighter Protection

Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Put on appropriate personal protective equipment.

Small spill

Stop leak if without risk. Move containers from spill area. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.

Large spill

Stop leak if without risk. Move containers from spill area. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations (see Section 13). Dispose of via a licensed waste disposal contractor.

Environmental

Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers.

Cleanup methods

Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container.

Materials: inert dry material, non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Put on appropriate personal protective equipment (see Section 8).

Storage

Store in accordance with local regulations. Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabeled containers. Use appropriate containment to avoid environmental contamination.

Hygiene

Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Good general ventilation should be sufficient to control worker exposure to airborne contaminants.

Hands

Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary.

Eyes

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: safety glasses with side-shields.

Respiratory

Use a properly fitted, air-purifying or air-fed respirator complying with an approved standard if a risk assessment indicates this is necessary. Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator.

Skin/Body

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

Environmental

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Solidification Point
---
Physical State
Liquid. [Viscous liquid.]
Cloud Point
---
Solubility
Insoluble in the following materials: cold water and hot water.
Decomposition Temperature
Not available.
Solubility In Fat
---
Auto Ignition Temperature
Not available.
Kinematic Viscosity
>0.21 cm²/s (>21 cSt)
Ph
Not available.
Density
---
Bulk Density
---
Boiling Point
207 to 750°C (404.6 to 1382°F)
Properties Status
---
Colour Intensity
---
Physical State Data
liquid
Softening Point
---
Voc Content
---
Dynamic Viscosity
---
Relative Density
0.934
Melting Point
0°C (32°F)
Molecular Weight
---
Flammability
Not available.
Relative Evaporation Rate
---
Colour
Colorless to light yellow.
Solubility In Water
Insoluble in the following materials: cold water and hot water.
Lower Explosive Limit
Not available.
State Under Standard Conditions
---
Odor Threshold
Not available.
Flash Point
Open cup: 237°C (458.6°F) [Cleveland.]
Partition Coefficient
>6
Metal Corrosion
---
Odor
Hydrocarbon.
Explosive Limits
---
Vapor Density
Not available.
Form
---
Freezing Point
---
Evaporation Rate
Not available.
Vapor Pressure
<0.011 kPa (<0.08 mm Hg) [room temperature]
Crystallisation Point
---
Upper Explosive Limit
Not available.
Appearance
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable.

Reactivity

No specific test data related to reactivity available for this product or its ingredients.

Hazardous reactions

Under normal conditions of storage and use, hazardous reactions will not occur.

Avoid

No specific data.

Incompatible

No specific data.

Decomposition

Under normal conditions of storage and use, hazardous decomposition products should not be produced.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

Toxicity

Toxicity Product/ingredient name Result Species Exposure Distillates (petroleum), hydrotreated heavy naphthenic Acute EC50 >100 mg/l Algae 72 hours Acute EC50 >100 mg/l Crustaceans 48 hours Acute LC50 >100 mg/l Fish 96 hours

Persistence and degradability

Persistence and degradability Product/ingredient name Aquatic half-life Photolysis Biodegradability Distillates (petroleum), hydrotreated heavy naphthenic - - Inherent

Bioaccumulative potential

Bioaccumulative potential Product/ingredient name Distillates (petroleum), hydrotreated heavy naphthenic LogPow BCF Potential >6 - high

Mobility in soil

Mobility in soil Soil/water partition : Not available. coefficient (KOC)

Other adverse effects

Other adverse effects : No known significant effects or critical hazards.

No known significant effects or critical hazards.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Dispose of surplus and non-recyclable products via a licensed waste disposal contractor. Waste should not be disposed of untreated to the sewer unless fully compliant with the requirements of all authorities with jurisdiction.

Disposal

The generation of waste should be avoided or minimized wherever possible. Dispose of surplus and non-recyclable products via a licensed waste disposal contractor.

Waste Codes

Not Regulated RCRA
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
Not regulated.
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is IRM 902 known by?

IRM 902 is also known as: Baseoil - unspecified; Hydrotreated heavy naphthenic distillate solvent extract (petroleum); Distillates, petroleum, hydrotreated heavy naphthenic; Hydrotreated heavy naphthenic distillate, solvent extract, petroleum; Mineral oil, petroleum distillates, hydrotreated heavy naphthenic; Mineral oil, petroleum distillates, hydrotreated (severe) heavy naphthenic; Distillates (petroleum), hydro-treated heavy naphthenic; Base oil — unspecified

What is the hazard signal word for IRM 902?

The signal word is no signal word.

What is the physical form of IRM 902?

IRM 902 is a liquid. [viscous liquid.] with colorless to light yellow. color. It has hydrocarbon. odor.

What is the solubility of IRM 902?

Insoluble in the following materials: cold water and hot water.

What is IRM 902 used for?

Petrochemical industry: Petroleum refining. Naphthenic Lubricant.

What are the hazard statements for IRM 902?

This substance has 1 hazard statement:

  • No known significant effects or critical hazards.

What is the melting point of IRM 902?

The melting point is 0°C (32°F) and the boiling point is 207 to 750°C (404.6 to 1382°F).