01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
UTHERM insulation products
Product Form
insulation boards

Regulatory Identifiers

CAS Number
N/A

Manufacturers & Suppliers

U

UNILIN division insulation

manufacturer

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Rigid polyisocyanurate foam according to EN13165 product standard. Facings: Alu stucco foil, Composite foil, Mineral coated glass tissue, Bitumen coated glass tissue, Plasterboard, OSB, Gypsum fibre, Mineral fibre, Particle board.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

In case of inhalation of dust, remove the person to fresh air.

Skin contact

Rinse well in running water.

Symptoms: Non-sensitising. When coated glass tissue and mineral fibre is handled, skin irritation may occur.

Eye contact

Dust particles should be removed by flushing with clean water. When penetrated with mineral fibre, do not rub, rinse thoroughly with water and seek medical advice.

Immediate Medical Attention

When penetrated with mineral fibre, seek medical advice.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

water spray, foam or dry powder

Firefighter Protection

Fire fighters should use self-contained breathing apparatus to prevent inhalation of toxic products of combustion.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

For handling aluminium faced boards, it is recommended to use protective gloves to avoid cuts. Do not expose the product to fire or any heat source for a long period of time.

Storage

Store in original packing. Store on a dry and level surface.

Fire prevention

Store in a location free from any ignition hazard such as open flames, cutting and welding torches, high surface electric heaters and other forms of direct radiant heating.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Where dust is generated through mechanical cutting in confined spaces, it is recommended that extraction be used.

Hands

It is recommended to wear protective gloves, in case of handling aluminium faced products, to protect against burns through contact with hot bitumen, to avoid skin irritation in contact with glass fibre and glass tissue.

Eyes

Eye protection recommended during mechanical cutting. When installing a product with reflective foil facings in very bright or sunny weather it is advisable to wear UV protective sunglasses or goggles.

Respiratory

As with all cutting procedures, it is recommended that a disposable dust mask be worn.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
solid
Physical State Data
solid
State Under Standard Conditions
---
Appearance
Creamy coloured solid foam with different type of facings
Colour
Creamy coloured
Colour Intensity
---
Form
solid foam
Odor
Negligible
Odor Threshold
---
Ph
Neutral under normal conditions
Melting Point
Not applicable
Boiling Point
---
Flash Point
Not applicable
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
---
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
Typically, between 27 to 35 kg/m³
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
Insoluble
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

12.2 Persistence and degradability

12.3 Bioaccumulative potential

12.4 Mobility in soil

12.5 Results of PBT and vPvB assessment

12.6 Endocrine disrupting properties

12.7 Other adverse effects

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Not applicable.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for UTHERM insulation products?

The signal word is no signal word.

What is the physical form of UTHERM insulation products?

UTHERM insulation products is a solid appearing as creamy coloured solid foam with different type of facings with creamy coloured color. It has negligible odor.

What is the melting point of UTHERM insulation products?

The melting point is Not applicable .