01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
THERMAGUARD TC 1200
Product Code
H15-1

Regulatory Identifiers

CAS Number
N/A

Identified Uses

solvent based, one component siloxane coating

Manufacturers & Suppliers

P

Performance Polymers EMEA B.V.

manufacturer

Snekertrekweg 57, 8912 AA Leewarden - Netherlands

+31(0)208208370

Emergency Contacts

National Poisoning Information Center (NVIC)

+31 (0)30 2748888

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Flam. Liq. Cat. 3 H226
Skin Irrit. Cat. 2 H315
Eye Irrit. Cat. 2 H319
STOT RE Cat. 2 H373

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

Hazard Statements

H226 Flammable liquid and vapour.
H315 Causes skin irritation.
H319 Causes serious eye irritation.
H373 May cause damage to organs through prolonged or repeated exposure.

Precautionary Statements

P210 Keep away from open flames. - No smoking.
P241 Use explosion-proof electrical/ventilating/lighting equipment.
P280 Wear protective gloves/protective clothing/eye protection/face protection.
P303 + P361 + P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/ shower.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P501 Dispose of contents/container in accordance with local/regional/national/international regulations.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mixture of substances listed below with nonhazardous additions.

Chemical Name CAS Number Concentration Hazardous
xylene EC: 215-535-7 1330-20-7 10 - 25% Yes
Quartz (SiO2) EC: 238-878-4 14808-60-7 10 - 25% Yes

For the wording of the listed hazard phrases refer to section 16.

Notes

Percentages of the components are expressed as a percentage by weight

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

In case of unconsciousness place patient stably in side position for transportation.

Skin contact

Immediately wash with water and soap and rinse thoroughly.

Eye contact

Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.

Ingestion

If symptoms persist consult doctor.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.

Unsuitable media

Water with full jet

Specific hazards

During heating or in case of fire poisonous gases are produced.

Firefighter Protection

Mouth respiratory protective device.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Mount respiratory protective device. Wear protective equipment. Keep unprotected persons away.

Environmental

Do not allow to enter sewers/ surface or ground water.

Cleanup methods

Absorb with liquid-binding material

Materials: sand, diatomite, acid binders, universal binders, sawdust

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Storage

Store material in original, well-closed packages in a cool, well-ventilated area according to local regulations. Keep container tightly sealed.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use only with adequate ventilation. Use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits. The engineering controls also need to keep gas, vapour or dust concentrations below any lower explosive limits. Use explosion-proof ventilation equipment.

Hands

Chemical resistant gloves (EN 374). Check protective gloves prior to each use for their proper condition. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: Fluorocarbon rubber (Viton). Penetration time of glove material: KCL Vitoject 890, breakthrough time > 480 min., thickness: 0,7 mm. At limited contact: KCL Camatril 730, breakthrough time 30 min., thickness: 0,4 mm. The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed. Not suitable are gloves made of the following materials: All other materials.

Eyes

Tightly sealed goggles. Safety glasses according to EN 166 or equivalent.

Respiratory

In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use self-contained respiratory protective device. Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator. If workers are exposed to concentrations above the exposure limit, they must use appropriate, certified respirators. Use a properly fitted, air-purifying or air-fed respirator complying with an approved standard if a risk assessment indicates this is necessary. For organic vapors and solvents type of filter A1 or A2, for dust type of filter P (according to EN 140)

Skin/Body

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved before the product is used by a specialist. If there is a risk of ignition by static electricity, anti-static protective clothing should be worn. For the best protection against static discharge, clothing should consist of anti-static overalls, boots and gloves. For further information on materials and design requirements and test methods consult the European standard EN 1149.

Environmental

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Form: Fluid Colour: According to product specification Odour: Characteristic
Colour
According to product specification
Colour Intensity
---
Form
Fluid
Odor
Characteristic
Odor Threshold
Not determined.
Ph
Not determined.
Melting Point
Undetermined.
Boiling Point
137 °C
Flash Point
30 °C
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not determined.
Vapor Pressure
6.7 hPa (at 20 °C)
Vapor Density
Not determined.
Relative Density
Not determined.
Bulk Density
---
Density
1.58 g/cm³ (at 20 °C)
Flammability
Not applicable.
Upper Explosive Limit
7 Vol %
Lower Explosive Limit
1.1 Vol %
Explosive Limits
---
Auto Ignition Temperature
Product is not selfigniting.
Decomposition Temperature
Not determined.
Solubility
---
Partition Coefficient
Not determined.
Solubility In Water
Not miscible or difficult to mix.
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
380 mPas (at 20 °C)
Kinematic Viscosity
> 20,5 mm²/s (at 40 °C)
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Reactivity

No further relevant information available.

Hazardous reactions

No dangerous reactions known.

Avoid

No further relevant information available.

Incompatible

No further relevant information available.

Decomposition

No dangerous decomposition products known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

- 12.1 Toxicity

12.1 Toxicity

Aquatic toxicity: - 1330-20-7 xylene - EC50/72 h 1-10 mg/l (Algae, Growth inhibition test) - EC50/48 h 1-10 mg/l (Daphnia magna) - LC50/96 h 1-10 mg/l (Oncorhynchus mykiss)

12.2 Persistence and degradability

No further relevant information available.

12.3 Bioaccumulative potential

No further relevant information available.

12.4 Mobility in soil

No further relevant information available.

No further relevant information available.

12.5 Results of PBT and vPvB assessment

PBT: Not applicable. vPvB: Not applicable.

The substance does not meet the criteria for PBT or vPvB assessment.

12.6 Other adverse effects

No further relevant information available.
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Must not be disposed together with household garbage.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1263
Shipping Name
PAINT
Transport Class
3
Packing Group
III
ADR

Warning: Flammable liquids.

IMDG

Warning: Flammable liquids.

IATA

Warning: Flammable liquids.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for THERMAGUARD TC 1200?

The signal word is warning.

What is the physical form of THERMAGUARD TC 1200?

THERMAGUARD TC 1200 is a liquid appearing as form: fluid colour: according to product specification odour: characteristic with according to product specification color. It has characteristic odor.

What is THERMAGUARD TC 1200 used for?

solvent based, one component siloxane coating

What are the hazard statements for THERMAGUARD TC 1200?

This substance has 4 hazard statements:

  • H226: Flammable liquid and vapour.
  • H315: Causes skin irritation.
  • H319: Causes serious eye irritation.
  • H373: May cause damage to organs through prolonged or repeated exposure.

What is the melting point of THERMAGUARD TC 1200?