Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- HYDROBAT 2000
- Product Code
- 02520003
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- W7MG-J0DC-G001-FF5F
Identified Uses
Construction chemicals, Hydrophobing agent/ water repellent. SU3 Industrial uses, SU22 Professional uses, PC35 Washing and cleaning products, PROC7 Industrial spraying, PROC10 Roller application or brushing, PROC11 Non industrial spraying, PROC9 Transfer of substance or mixture into small containers, ERC8d Widespread use of non-reactive processing aid.
Manufacturers & Suppliers
ZEP ITALIA SRL
manufacturer
Piazzale Luigi Cadorna, 2, 20123 Milano (MI) - Italy; Via Nettunense Km. 25.000, 04011 Aprilia (LT) - Italy
+39.06.926691
http://www.zep.it
ZEP Industries BV
manufacturer
Vierlinghweg 30, 4612 PN Bergen op Zoom, The Netherlands
+31 164 250 100
ZEP UK Ltd
distributor
Tanhouse Lane, Widnes Cheshire, WA8 0RD, United Kingdom
+44 (0)151 422 1000
http://www.zep.co.uk
Emergency Contacts
NHS
+44 0845 46 47
NHS
+44 08454 24 24 24
Emergency Contact
112
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Mixture of substances listed below with nonhazardous additions.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Hydrocarbons, C10-C13, n-alkanes, isoalkanes, cyclics, <2% aromatics EC: 918-481-9 | --- | 75 - 100% | Yes |
| tetraethyl silicate EC: 201-083-8 | 78-10-4 | 0.1 - 1% | Yes |
For the wording of the listed hazard phrases refer to section 16.
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air; consult doctor in case of complaints.
If skin irritation continues, consult a doctor. Immediately wash with water and soap and rinse thoroughly. Immediately rinse with water.
Rinse opened eye for several minutes under running water. Then consult a doctor.
Do not induce vomiting; call for medical help immediately.
Immediate Medical Attention
Call for medical help immediately.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
Water with full jet
No further relevant information available.
Firefighter Protection
No special measures required.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Wear protective equipment. Keep unprotected persons away. Ensure adequate ventilation.
Prevent seepage into sewage system, workpits and cellars. Do not allow to enter sewers/ surface or ground water.
Absorb with liquid-binding material (sand, diatomite, universal binders). Dispose contaminated material as waste according to section 13.
Materials: sand, diatomite, universal binders
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Ensure good ventilation/exhaustion at the workplace. Prevent formation of aerosols. Use only in well ventilated areas.
Provide solvent resistant, sealed floor. Keep receptacle tightly sealed.
Keep ignition sources away - Do not smoke. Protect against electrostatic charges.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No further data; see section 7.
Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: Nitrile rubber, NBR, PVA gloves. Penetration time: at least 480 minutes (Permeation according to EN 16523-1:2015: Level 0.45mm). Not suitable: Strong material gloves.
Tightly sealed goggles
Use suitable respiratory protective device only when aerosol or mist is formed. Filter AX
Solvent resistant protective clothing
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used according to specifications.
No further relevant information available.
No dangerous reactions known.
No further relevant information available.
No further relevant information available.
No dangerous decomposition products known.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Disposal must be made according to official regulations
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- Void
- Shipping Name
- Void
- Transport Class
- Void
- Packing Group
- Void
Not applicable.
Not applicable.
Not applicable.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Safety data sheet according to 1907/2006/EC, Article 31
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for HYDROBAT 2000?
The signal word is danger.
What is the physical form of HYDROBAT 2000?
HYDROBAT 2000 is a fluid with colourless color. It has solvent-like odor.
What is HYDROBAT 2000 used for?
Construction chemicals, Hydrophobing agent/ water repellent. SU3 Industrial uses, SU22 Professional uses, PC35 Washing and cleaning products, PROC7 Industrial spraying, PROC10 Roller application or brushing, PROC11 Non industrial spraying, PROC9 Transfer of substance or mixture into small containers, ERC8d Widespread use of non-reactive processing aid.
What are the hazard statements for HYDROBAT 2000?
This substance has 1 hazard statement:
- H304: May be fatal if swallowed and enters airways.
What is the melting point of HYDROBAT 2000?
The melting point is Undetermined. and the boiling point is 180 °C.