NextSDS Logo
Im

Imperon Blue K-B

NO SIGNAL WORD SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Imperon Blue K-B
Product Form
Plastic drum with cover, 30l

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Textile dye

Overview

Imperon Blue K-B commonly used textile dye.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

Hazard Classifications

Not Classified

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

DyStar Colours Distribution GmbH

undefined

๐Ÿ“

Am Prime Park 10-12 D - 65479 Raunheim

๐ŸŒ

DE

๐Ÿ“ž

+49 6142 4072 3172

๐Ÿ“ 

+49 6142 4072 3000

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

+49 2365 4984140

๐ŸŒ

DE

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Mixture

General Composition

phthalocyanine copper complex pigment preparation, aqueous preparation

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
1,2-propylene glycol
EC: 200-338-0
57-55-6 3-8% โš ๏ธ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Upon inhalation of aerosol/vapour/dust: Take the patient into the fresh air; if there is difficulty in breathing, medical advice is required.

๐Ÿ–๏ธ Skin Contact

Cleansing with plenty of water, soap or other non-irritating cleansing agents.

๐Ÿ‘๏ธ Eye Contact

Contamination of the eyes must be treated by thorough irrigation with water, with the eyelids held open. Eventually a doctor (or eye specialist) should be consulted.

๐Ÿฝ๏ธ Ingestion/Swallowing

If the product is swallowed, the patient must at once drink water repeatedly, if possible with the addition of activated carbon. If the patient feels unwell, seek medical advice.

๐Ÿšจ Immediate Medical Attention Required

Please see precautionary statements in section 2.2 as well as first aid information in this section if stated.

Medical Treatment

Please see precautionary statements in section 2.2 as well as first aid information in this section if stated.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Not available
๐Ÿ“Š Physical State Data
Not available
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
blue
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
liquid
๐Ÿ‘ƒ Odor
product specific
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
approx. 6 - 9 (20 C)
๐ŸงŠ Melting Point
Not available
๐Ÿ’จ Boiling Point
approx. 100 C
Critical Property
๐Ÿ”ฅ Flash Point
> 100 C
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
approx. 0 C
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
not determined
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
not determined
โš–๏ธ Density
approx. 1,1 g/cm3 (20 C)
Critical Property
๐Ÿ”ฅ Flammability
not determined
๐Ÿ“Š Upper Explosive Limit
not determined
๐Ÿ“Š Lower Explosive Limit
not determined
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
not determined
๐Ÿ“Š Decomposition Temperature
Not available
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
not determined
๐Ÿ“Š Solubility In Water
miscible
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
not determined
๐Ÿ“Š Kinematic Viscosity
not determined
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿงค Hand Protection

Wear suitable gloves e.g. of PVC or nitrile rubber. In the event of contamination, change protective gloves immediately. Avoid skin contact with the wetted surfaces of the protective gloves.

๐Ÿ‘๏ธ Eye Protection

safety glasses with side protection shield

๐Ÿ˜ท Respiratory Protection

combination filter, e.g. DIN 3181 ABEK, if product forms vapours.

๐Ÿฆบ Skin/Body Protection

Wear protective clothing.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Imperon Blue K-B?

The signal word for this substance is "no signal word".

What is Imperon Blue K-B used for?

Textile dye