NextSDS Logo
Safety Data Sheet EN

Impermax® SP 50

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Impermax® SP 50
Product Form
Mixture
Product Code
908177

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Particle board industry, MDF & OSB. Water repellent agent for wood.

Uses advised against

No additional information available

Manufacturers & Suppliers

s.a. GOVI n.v. logo

s.a. GOVI n.v.

manufacturer

Landegemstraat 8, B-9031 Drongen - België-Belgique-Belgium

http://www.govi.com

Emergency Contacts

Emergency Contact

+32 (0)9 282 94 95

8h30 - 17h

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

This mixture does not contain any substances to be mentioned according to the criteria of section 3.2 of REACH annex II

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Assure fresh air breathing. Allow the victim to rest. Obtain medical attention if breathing difficulty persists.

Skin contact

Remove affected clothing and wash all exposed skin area with mild soap and water, followed by warm water rinse. Seek medical attention if ill effect or irritation develops.

Eye contact

IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Obtain medical attention if pain, blinking or redness persists.

Ingestion

Rinse mouth. Do NOT induce vomiting. Seek medical attention if ill effect develops.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Foam. Dry powder. Carbon dioxide. Water spray. Sand.

Unsuitable media

None to our knowledge.

Specific hazards

No additional information available

Instructions

Use water spray or fog for cooling exposed containers. Exercise caution when fighting any chemical fire. Prevent fire fighting water from entering the environment.

Firefighter Protection

Do not enter fire area without proper protective equipment, including respiratory protection.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Evacuate unnecessary personnel. Ventilate area.

Environmental

Prevent entry to sewers and public waters.

Cleanup methods

Use appropriate container to avoid environmental contamination. Clean up any spills as soon as possible, using an absorbent material to collect it. Use suitable disposal containers.

Materials: absorbent material, suitable disposal containers

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Handle in accordance with good industrial hygiene and safety procedures. Wear appropriate personal protective equipment. (See section 8). Mix well before use. Avoid excessive shear through intensive / prolonged mixing, pumping with no suitable pumps which produce high shear (eg centrifugal, gear pumps etc. ...).

Storage

Keep container closed when not in use. Store in dry, well-ventilated area. This material is an emulsion which may stratify upon prolonged storage or by evaporation. Protect from freezing.

Hygiene

Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Protective gloves made of rubber.

Eyes

Chemical goggles or safety glasses.

Respiratory

No special respiratory protection equipment is recommended under normal conditions of use with adequate ventilation.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Form
---
Density
0.9 - 0.975 kg/l
Odor Threshold
No data available
Flash Point
Not applicable
Explosive Limits
---
Physical State Data
liquid
Softening Point
---
State Under Standard Conditions
---
Crystallisation Point
---
Appearance
---
Ph
8 - 10
Physical State
Liquid
Kinematic Viscosity
No data available
Relative Density
No data available
Freezing Point
≈ 0 °C
Colour Intensity
---
Boiling Point
≈ 100 °C
Dynamic Viscosity
< 100 mPa.s
Bulk Density
---
Decomposition Temperature
No data available
Metal Corrosion
---
Solubility
Miscible.
Molecular Weight
---
Solubility In Water
---
Odor
Negligible.
Lower Explosive Limit
No data available
Properties Status
---
Upper Explosive Limit
No data available
Relative Evaporation Rate
No data available
Melting Point
No data available
Solidification Point
---
Flammability
Non flammable.
Evaporation Rate
---
Solubility In Fat
---
Vapor Density
---
Partition Coefficient
No data available
Auto Ignition Temperature
No data available
Cloud Point
---
Voc Content
---
Colour
White.
Vapor Pressure
No data available
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable at normal handling and storage conditions.

Reactivity

The product is stable at normal handling and storage conditions.

Hazardous reactions

Not established.

Avoid

Freezing. Extremely high or low temperatures.

Incompatible

Cationic products. Strong oxidizers. Acids.

Decomposition

Thermal decomposition generates ; Carbon monoxide. Carbon dioxide. Nitrogen oxides.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Dispose in a safe manner in accordance with local/national regulations.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Impermax® SP 50?

The signal word is no signal word.

What is the physical form of Impermax® SP 50?

Impermax® SP 50 is a liquid with white. color. It has negligible. odor.

What is the solubility of Impermax® SP 50?

Miscible.

What is Impermax® SP 50 used for?

Particle board industry, MDF & OSB. Water repellent agent for wood.

What is the melting point of Impermax® SP 50?