Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- KEMPEROL 2K-PUR (B)
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Waterproofing, intended for professional use only!
Manufacturers & Suppliers
KEMPER SYSTEM GmbH & Co. KG
manufacturer
Holländische Strasse 32-36, 34246 Vellmar, Deutschland / Germany
+49 (0)561 / 8295-0
Emergency Contacts
Giftinformationszentrum der Länder Rheinland-Pfalz und Hessen
+49 (0)6131 / 19 24 0
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Mixture: consisting of the following components.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Isocyanic acid, polymethylenepolyphenylene ester EC: 618-498-9 | 9016-87-9 | 50 - 100% | Yes |
| Reaction mass of 4,4'-methylenediphenyl diisocyanate and o-(p-isocyanatobenzyl)phenyl isocyanate EC: 905-806-4 | --- | 10 - 12.5% | Yes |
| 4,4'-methylenediphenyl diisocyanate EC: 247-714-0 | 101-68-8 | 2.5 - 10% | Yes |
For the wording of the listed hazard phrases refer to section 16.
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air; consult doctor in case of complaints.
Immediately wash with water and soap and rinse thoroughly.
Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor. Protect unharmed eye.
Immediate Medical Attention
Seek medical treatment in case of complaints. If symptoms persist consult doctor.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam. Use fire extinguishing methods suitable to surrounding conditions.
Carbon monoxide (CO), Nitrogen oxides (NOx), Formation of toxic gases is possible during heating or in case of fire.
Use fire extinguishing methods suitable to surrounding conditions.
Firefighter Protection
Mouth respiratory protective device. Do not inhale explosion gases or combustion gases.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Wear protective equipment. Keep unprotected persons away.
Inform respective authorities in case of seepage into water course or sewage system. Prevent from spreading (e.g. by damming-in or oil barriers). Do not allow to enter sewers/ surface or ground water.
Absorb with liquid-binding material. Do not flush with water or aqueous cleansing agents.
Materials: sand, diatomite, acid binders, universal binders, sawdust
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Store in cool, dry place in tightly closed receptacles. Ensure good ventilation/exhaustion at the workplace. Prevent formation of aerosols.
Store in cool, dry place in tightly closed receptacles. Store only in the original receptacle. Store away from foodstuffs. Recommended storage temperature: 10-30 °C. Protect from frost. Store in dry conditions. Keep container tightly sealed.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No further data; see item 7.
Protective gloves. Check protective gloves prior to each use for their proper condition. Only use chemical-protective gloves with CE-labelling of category III. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. After use of gloves apply skin-cleaning agents and skin cosmetics. Recommended materials: Butyl rubber, BR. Recommended thickness of the material: ≥ 0.5 mm. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. Penetration time: The determined penetration times according to EN 374 part III are not performed under practical conditions. Therefore a maximum wearing time, which corresponds to 50% of the penetration time, is recommended. As protection from splashes gloves made of the following materials are suitable: Nitrile rubber, NBR. Recommended thickness of the material: ≥ 0.1 mm. Penetration time (min.): <10.
Tightly sealed goggles. Protective goggles and facial protection - Classification according to EN 166.
When used properly and under normal conditions, breathing protection is not required. Use suitable respiratory protective device in case of insufficient ventilation. Filter A/P2. Respiratory protection - Gas filters and combination filters according to EN 141.
Protective work clothing. Impervious protective clothing.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used according to specifications.
Exothermic reaction.
alcohols, amines, aqueous acids and alkalis
Hydrocarbons, Carbon monoxide and carbon dioxide, Nitrogen oxides (NOx)
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Must not be disposed together with household garbage. Do not allow product to reach sewage system. Disposal according to official regulations
Disposal according to official regulations
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- Void
- Shipping Name
- Void
- Transport Class
- Void
- Packing Group
- Void
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for KEMPEROL 2K-PUR (B)?
The signal word is danger.
What is the physical form of KEMPEROL 2K-PUR (B)?
KEMPEROL 2K-PUR (B) is a fluid appearing as fluid with brown color. It has slight musty odor.
What is KEMPEROL 2K-PUR (B) used for?
Waterproofing, intended for professional use only!
What are the hazard statements for KEMPEROL 2K-PUR (B)?
This substance has 8 hazard statements:
- H315: Causes skin irritation.
- H317: May cause an allergic skin reaction.
- H319: Causes serious eye irritation.
- H332: Harmful if inhaled.
- H334: May cause allergy or asthma symptoms or breathing difficulties if inhaled.
- H335: May cause respiratory irritation.
- H351: Suspected of causing cancer.
- H373: May cause damage to organs through prolonged or repeated exposure.
What is the melting point of KEMPEROL 2K-PUR (B)?
The melting point is Undetermined. and the boiling point is Undetermined..