NextSDS Logo
SI

SIP100PE UFI

DANGER Liquid. SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
SIP100PE UFI
Product Form
Wipes/liquid
Product Code
6244SEIPA99E

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

UFI Code
RHE8-J07Q-H005-QM36

Unique Formula Identifier - for poison centres and emergency response

Uses Information

Identified Uses
Cleaning products Wipes Industrial/Professional use
Uses Advised Against
Not applicable.

Overview

SIP100PE UFI is a not available. substance commonly used cleaning products wipes industrial/professional use.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Flam. Liq. Category 2 H225
Eye Irrit. Category 2 H319
STOT SE Category 3 H336

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H225: Highly flammable liquid and vapour.
  • H319: Causes serious eye irritation.
  • H336: May cause drowsiness or dizziness.

Precautionary Statements

  • Wear eye or face protection. Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Avoid breathing vapour.
  • IF INHALED: Call a POISON CENTER or doctor if you feel unwell. IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If eye irritation persists: Get medical advice or attention.
  • Store in a well-ventilated place. Keep container tightly closed.
  • Dispose of contents and container in accordance with all local, regional, national and international regulations.
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Chemtronics

manufacturer

8125 Cobb Center Drive Kennesaw, GA 30152

US

770-424-4888

ITW Contamination Control BV company logo - Safety Data Sheet supplier organization

ITW Contamination Control BV

importer

Saffierlaan 5 VZ-2132 Hoofddorp The Netherlands

NL

+31 88 1307 400

+31 88 1307 499

Importer/Only Representative

undefined

Bay 150 Shannon Industrial Estate Shannon County Clare Ireland V14 DF82

IE

+353 61 771 500

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

United Kingdom (England or Wales) National advisory body/Poison Centre

0845 46 47

GB

EMERGENCY HEALTH INFORMATION

Scotland National advisory body/Poison Centre

08454 24 24 24

GB

EMERGENCY HEALTH INFORMATION (UK only)

Chemtronics Product Information

800-TECH-401 (800-832-4401)

US

8:00 AM to 5:00 PM

EMERGENCY HEALTH INFORMATION; EMERGENCY SPILL INFORMATION; Transport information

Chemtronics Customer Service

800-645-5244

US

8:00 AM to 5:00 PM

EMERGENCY HEALTH INFORMATION; EMERGENCY SPILL INFORMATION; Transport information

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
propan-2-ol
EC: 200-661-7
67-63-0 50-75% Hazardous

Composition Notes

There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment, are PBTs, vPvBs or Substances of equivalent concern, or have been assigned a workplace exposure limit and hence require reporting in this section.

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Remove victim to fresh air and keep at rest in a position comfortable for breathing. If it is suspected that fumes are still present, the rescuer should wear an appropriate mask or self-contained breathing apparatus. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. Get medical attention. If necessary, call a poison center or physician. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Symptoms:

Adverse symptoms may include the following: nausea or vomiting, headache, drowsiness/fatigue, dizziness/vertigo, unconsciousness

Skin Contact

Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Get medical attention if symptoms occur. Wash clothing before reuse. Clean shoes thoroughly before reuse.

Symptoms:

Adverse symptoms may include the following: irritation, redness, dryness, cracking

Eye Contact

Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes. Get medical attention.

Symptoms:

Adverse symptoms may include the following: pain or irritation, watering, redness

Ingestion/Swallowing

Wash out mouth with water. Remove dentures if any. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Do not induce vomiting unless directed to do so by medical personnel. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Get medical attention. If necessary, call a poison center or physician. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Symptoms:

Adverse symptoms may include the following: Ingestion Seek medical attention.

Immediate Medical Attention Required

Treat symptomatically. Contact poison treatment specialist immediately if large quantities have been ingested or inhaled.

Medical Treatment

Treat symptomatically. No specific treatment.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Physical State
Liquid.
Critical Property
Physical State Data
liquid
State Under Standard Conditions
Not available
Appearance
Not available.
Colour
Not available.
Colour Intensity
Not available
Form
Not available
Odor
Not available.
Odor Threshold
Not available.
Ph
Not available.
Melting Point
Not available.
Critical Property
Boiling Point
Not available.
Critical Property
Flash Point
16°C (60.8°F)
Critical Property
Freezing Point
Not available.
Softening Point
Not available
Solidification Point
Not available
Cloud Point
Not available
Crystallisation Point
Not available
Relative Evaporation Rate
Not available
Evaporation Rate
<1 (butyl acetate = 1)
Vapor Pressure
Not available.
Vapor Density
Not available.
Relative Density
0.88
Bulk Density
Not available
Density
Not available
Flammability
Not available.
Upper Explosive Limit
7.7%
Lower Explosive Limit
1.2%
Explosive Limits
Not available
Auto Ignition Temperature
Not applicable
Decomposition Temperature
Not available.
Solubility
Yes.
Partition Coefficient
Not available.
Solubility In Water
Yes.
Solubility In Fat
Not available
Molecular Weight
Not available
Voc Content
Not available
Metal Corrosion
Not available
Dynamic Viscosity
Not available.
Kinematic Viscosity
Not available.
Properties Status
Not available
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Use only with adequate ventilation. Use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits. The engineering controls also need to keep gas, vapour or dust concentrations below any lower explosive limits. Use explosion-proof ventilation equipment.

Hand Protection

Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Considering the parameters specified by the glove manufacturer, check during use that the gloves are still retaining their protective properties. It should be noted that the time to breakthrough for any glove material may be different for different glove manufacturers. In the case of mixtures, consisting of several substances, the protection time of the gloves cannot be accurately estimated.

Eye Protection

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: chemical splash goggles.

Respiratory Protection

Based on the hazard and potential for exposure, select a respirator that meets the appropriate standard or certification. Respirators must be used according to a respiratory protection program to ensure proper fitting, training, and other important aspects of use.

Skin/Body Protection

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. When there is a risk of ignition from static electricity, wear anti-static protective clothing. For the greatest protection from static discharges, clothing should include anti-static overalls, boots and gloves. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

Environmental Exposure Controls

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

UN3175

Proper Shipping Name

Solids containing flammable liquid, n.o.s.(CONTAINS Propan-2-ol)

Transport Hazard Class

4.1

Packing Group

II

ADR Transport Precautions

Transport within user’s premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

IMDG Maritime Transport Precautions

Transport within user’s premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

IATA Air Transport Precautions

Transport within user’s premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for SIP100PE UFI?

The signal word for this substance is "danger".

What is the physical form of SIP100PE UFI?

SIP100PE UFI is a liquid. appearing as not available. with not available. color. It has not available. odor.

What is the solubility of SIP100PE UFI?

Yes.

What is SIP100PE UFI used for?

Cleaning products Wipes Industrial/Professional use

What are the hazard statements for SIP100PE UFI?

This substance has 3 hazard statements: H225: Highly flammable liquid and vapour. H319: Causes serious eye irritation. H336: May cause drowsiness or dizziness.

What is the melting point of SIP100PE UFI?

The melting point is Not available. and the boiling point is Not available..